The John Charnley Award: Highly Crosslinked Polyethylene in Total Hip Arthroplasty Decreases Long-term Wear: A Double-blind Randomized Trial
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The use of highly crosslinked polyethylene (HXLPE) is now commonplace for total hip arthroplasty. Hip simulator studies and short-term in vivo measurements suggest that the wear rate of some types of HXLPE is significantly less than conventional ultrahigh-molecular-weight polyethylene (UHMWPE). However, there are few long-term data to support its use. QUESTIONS/PURPOSES: The aim of this study was to measure the long-term steady-state wear of HXLPE compared with UHMWPE liners in a prospective, double-blind, randomized controlled trial using radiostereometric analysis. METHODS: Fifty-four patients were randomized to receive hip arthroplasties with either UHMWPE liners or HXLPE liners. Complete followup was available on 39 of these patients (72%). All patients received the same cemented stem and an uncemented acetabular component. Three-dimensional penetration of the head into the socket was determined at 10 years using a radiostereometric analysis system, which has an in vivo accuracy of <0.1 mm. Oxford Hip Scores were compared between the groups. RESULTS: At 10 years there was significantly less wear of HXLPE (0.003 mm/year; 95% confidence interval [CI], ±0.010; SD 0.023; range, -0.057 to 0.074) compared with UHMWPE (0.030 mm/year; 95% CI, ±0.012; p<0.001; SD 0.0.27; range, -0.001 to 0.164). The volumetric penetration from 1 to 10 years for the UHMWPE group was 98 mm3 (95% CI, ±46 mm3; SD 102 mm3; range, -4 to 430 mm3) compared with 14 mm3 (95% CI, ±40 mm3; SD 91 mm3; range, -189 to 242 mm3) for the HXLPE group (p=0.01). CONCLUSIONS: This study demonstrates that HXLPE has little detectable steady-state in vivo wear. This may result in fewer reoperations from loosening; however, careful clinical followup into the second decade still needs to be performed. LEVEL OF EVIDENCE: Level I, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Practical Statistics for Medical Research.
Walter, S. D., & Altman, D. G. (1992) · Biometrics · doi:10.2307/2532320 · Cited by 11,668 · cited 1×
“Before the study, a sample size calculation was performed with use of an Altman nomogram [3].”
Practical Statistics for Medical Research
Altman, D. G. (1990) · doi:10.1201/9780429258589 · Cited by 10,668
Projections of Primary and Revision Hip and Knee Arthroplasty in the United States from 2005 to 2030
Kurtz, S., Ong, K., Lau, E., Mowat, F., & Halpern, M. (2007) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200704000-00012 · Cited by 8,698
QUESTIONNAIRE ON THE PERCEPTIONS OF PATIENTS ABOUT TOTAL HIP REPLACEMENT
Dawson, J., Fitzpatrick, R., Carr, A., & Murray, D. (1996) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.78b2.0780185 · Cited by 2,896
Self-citationA literature review of the association between wear rate and osteolysis in total hip arthroplasty
Dumbleton, J. H., Manley, M. T., & Edidin, A. A. (2002) · The Journal of Arthroplasty · doi:10.1054/arth.2002.33664 · Cited by 710 · cited 2×
“Particulate debris generated by wear of the liner in implants with metal-on-polyethylene bearing surfaces is one of the main stimulators of periprosthetic osteolysis and eventual aseptic loosening [8, 17, 20, 29].”
Kurtz, S. M., Gawel, H. A., & Patel, J. D. (2011) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-011-1872-4 · Cited by 468 · cited 1×
“Metaanalysis of 28 such studies has shown reduced femoral head penetration and 87% lower risk of osteolysis with HXLPE [25] at early and intermediate followup.”
Jacobs, J. J., Roebuck, K. A., Archibeck, M., Hallab, N. J., & Glant, T. T. (2001) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200112000-00008 · Cited by 367 · cited 1×
“Particulate debris generated by wear of the liner in implants with metal-on-polyethylene bearing surfaces is one of the main stimulators of periprosthetic osteolysis and eventual aseptic loosening [8, 17, 20, 29].”
Matthews, J. B., Besong, A. A., Green, T. R., Stone, M. H., Wroblewski, B. M., Fisher, J., & Ingham, E. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200011)52:2<296::aid-jbm8>3.0.co;2-9 · Cited by 212 · cited 2×
“It has been suggested that the threshold should be lower for HXLPE than UHMWPE because the particles generated are smaller and likely to be more biologically active [10, 31].”
Endo, M., Tipper, J. L., Barton, D. C., Stone, M. H., Ingham, E., & Fisher, J. (2002) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411021536333 · Cited by 190 · cited 1×
“However, it has been shown in vitro that the biological activity of HXLPE particles is the same or less compared with conventional UHMWPE particles [9, 12].”
Oparaugo, P. C., Clarke, I. C., Malchau, H., & Herberts, P. (2001) · Acta Orthopaedica Scandinavica · doi:10.1080/000164701753606644 · Cited by 166 · cited 1×
“For osteolysis and subsequent revision, the volume of wear debris is more important than the wear rate [35].”
The creep and wear of highly cross-linked polyethylene
Glyn-Jones, S., McLardy-Smith, P., Gill, H. S., & Murray, D. W. (2008) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.90b5.20545 · Cited by 138 · cited 2×
“We previously evaluated the results of a randomized trial comparing UHMWPE with HXLPE at 2 [14], 3 [15], and 7 years [41].”
Self-citationKuzyk, P. R. T., Saccone, M., Sprague, S., Simunovic, N., Bhandari, M., & Schemitsch, E. H. (2011) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.93b5.25908 · Cited by 129 · cited 1×
“However, with regard to whether HXLPE results in reduced revision rates, the one meta-analysis of which we are aware that evaluated this endpoint found no difference in the proportion of patients undergoing revision in those who received HXLPE and those who received UHMWPE [27].”
The Oxford hip score: the patient's perspective
Wylde, V., Learmonth, I. D., & Cavendish, V. J. (2005) · Health and Quality of Life Outcomes · doi:10.1186/1477-7525-3-66 · Cited by 113 · cited 8×
“Oxford Hip Scores The Oxford Hip Score is a patient-reported outcome measurement validated for use in THA [7, 44].”
InfluentialJohanson, P., Digas, G., Herberts, P., Thanner, J., & Kärrholm, J. (2012) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-012-2400-x · Cited by 104 · cited 3×
“We are aware of only one other randomized controlled trial using radiostereometric analysis (RSA) that compares wear rates of HXLPE with conventional UHMWPE liners at 10-year followup [21].”
Ries, M. D., Scott, M. L., & Jani, S. (2001) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200100022-00009 · Cited by 101 · cited 1×
“Even if the biological activity of HXLPE particles was greater than that of UHMWPE, this likely would be offset by the markedly lower wear rate [37].”
Endo, M. M., Barbour, P. S. M., Barton, D. C., Fisher, J., Tipper, J. L., Ingham, E., & Stone, M. H. (2001) · PubMed · Cited by 75
Comparative wear tests of ultra-high molecular weight polyethylene and cross-linked polyethylene
Harsha, A. P., & Joyce, T. J. (2013) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411913479528 · Cited by 33 · cited 1×
“Additionally, although the wear volume in HXLPE has been shown to be less in vitro than conventional UHMWPE [18, 19], some studies have suggested that it generates smaller particulate debris [10] that are more biologically active in stimulating osteolysis in vitro [31], whereas recent evidence suggests fewer small par…”
Orishimo, K. F., Claus, A. M., Sychterz, C. J., & Engh, C. A. (2003) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200306000-00018
Metadata
- Authors
- Glyn-Jones, S., Thomas, G. E. R., Garfjeld-Roberts, P., Gundle, R., Taylor, A., McLardy-Smith, P., & Murray, D. W.
- Venue
- Clinical Orthopaedics & Related Research
- Published
- 2015-02
- Volume
- 473
- Issue
- 2
- Pages
- 432-438
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2085444150
- Cited by
- 161
- References
- 18
- FWCI
- 13.74
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.