CoChat

What Was the Survival of Megaprostheses in Lower Limb Reconstructions After Tumor Resections?

Open access
Capanna, Rodolfo, Scoccianti, Guido, Frenos, Filippo, Vilardi, Antonio, Beltrami, Giovanni, Campanacci, Domenico Andrea · 2015 · Clinical Orthopaedics & Related Research
Cited by 159

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Prosthetic replacement is the most commonly used option for reconstruction of osteoarticular bone loss resulting from bone neoplasm resection or prosthetic failure. Starting in late 2001, we began exclusively using a single system for large-segment osteoarticular reconstruction after tumor resection; to our knowledge, there are no published series from one center evaluating the use of this implant. QUESTIONS/PURPOSES: We investigated the following issues: (1) What is the overall survival, excluding local tumor recurrence, for these endoprostheses used for tumor reconstructions of the lower extremities (knee and hip)? (2) What types of failure were observed in these reconstructions? (3) Do the survival and complications vary according to site of implant? METHODS: Between September 2001 and March 2012, we exclusively used this implant for tumor reconstructions. During that time, 278 patients underwent tumor reconstructions of the hip or knee, of whom 200 (72%) were available at a minimum 2 years followup. Seventy-eight patients were excluded from the study for insufficient followup as a result of early death (42) or loss at followup (36). The reconstruction types were the following: proximal femur (69 cases), distal femur (87), proximal tibia (32), and total knee (12). Failures were classified according to the Henderson classification. Nine patients among those with followup shorter than 2 years had presented one or more failures and they were included in our analysis but separately evaluated. RESULTS: Overall survival (no further surgical procedures of any type after primary surgery), excluding Type 5 failure (tumor recurrence), was 75.9% at 5 years and 66.2% at 10 years. Seventy-one failures occurred in 58 implants (29%). Mechanical failures accounted for 59.2% and nonmechanical failures for 40.8%. The first causes of failure of the implants were the result of soft tissue failure in 6%, aseptic loosening in 3%, structural failure in 7%, infection in 8.5%, and tumor recurrence in 4.5% of the whole series. Nine implants sustained two or more failures. Overall incidence of infection was 9.5%. No statistically significant differences were observed according to anatomical site. CONCLUSIONS: Like in the case with many such complex oncologic reconstructions, the failure rate at short- to midterm in this group was over 20%. Comparative trials are called for to ascertain whether one implant is superior to another. Infection and structural failure were the most frequent modes of failure in our experience. LEVEL OF EVIDENCE: Level IV, therapeutic study. See Instructions for Authors for a complete description of levels of evidence.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s11999-014-3736-1

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

Metadata

Authors
Capanna, R., Scoccianti, G., Frenos, F., Vilardi, A., Beltrami, G., & Campanacci, D. A.
Venue
Clinical Orthopaedics & Related Research
Published
2015-03
Volume
473
Issue
3
Pages
820-830
ISSN
0009-921X (ISSN-L)
OpenAlex
W1988560818
Cited by
159
References
10
FWCI
7.01
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.