The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
The Chitranjan S. Ranawat Award: No Difference in 2-year Functional Outcomes Using Kinematic versus Mechanical Alignment in TKA: A Randomized Controlled Clinical Trial
Open accessAbstract
BACKGROUND: Neutral mechanical alignment (MA) in total knee arthroplasty (TKA) aims to position femoral and tibial components perpendicular to the mechanical axis of the limb. In contrast, kinematic alignment (KA) attempts to match implant position to the prearthritic anatomy of the individual patient with the aim of improving functional outcome. However, comparative data between the two techniques are lacking. QUESTIONS/PURPOSES: In this randomized trial, we asked: (1) Are 2-year patient-reported outcome scores enhanced in patients with KA compared with an MA technique? (2) How does postoperative component alignment differ between the techniques? (3) Is the proportion of patients undergoing reoperation at 2 years different between the techniques? METHODS: Ninety-nine primary TKAs in 95 patients were randomized to either MA (n = 50) or KA (n = 49) groups. A pilot study of 20 TKAs was performed before this trial using the same patient-specific guides positioning in kinematic alignment. In the KA group, patient-specific cutting blocks were manufactured using individual preoperative MRI data. In the MA group, computer navigation was used to ensure neutral mechanical alignment accuracy. Postoperative alignment was assessed with CT scan, and functional scores (including the Oxford Knee Score, WOMAC, and the Forgotten Joint Score) were assessed preoperatively and at 6 weeks, 6 months, and 1 and 2 years postoperatively. No patients were lost to followup. We set sample size at a minimum of 45 patients per treatment arm based on a 5-point improvement in the mean Oxford Knee Score (OKS; the previously reported minimum clinically significant difference for the OKS in TKA), a pooled SD of 8.3, 80% power, and a two-sided significance level of 5%. RESULTS: We observed no difference in 2-year change scores (postoperative minus preoperative score) in KA versus MA patients for the OKS (mean 21, SD 8 versus 20, SD 8, least square means 1.0, 95% confidence interval [CI], -1.4 to 3.4, p = 0.4), WOMAC score (mean 38, SD 18 versus 35, SD 8, least square means 3, 95% CI, -3.2 to 8.9, p = 0.3), or Forgotten Joint score (28 SD 37 versus 28, SD 28, least square means 0.8, 95% CI, -9.1-10.7, p = 0.8). Postoperative hip-knee-ankle axis was not different between groups (mean KA 0.4° varus SD 3.5 versus MA 0.7° varus SD 2.0), but in the KA group, the tibial component was a mean 1.9° more varus than the MA group (95% CI, 0.8°-3.0°, p = 0.003) and the femoral component in 1.6° more valgus (95% CI, -2.5° to -0.7°, p = 0.003). Complication rates were not different between groups. CONCLUSIONS: We found no difference in 2-year patient-reported outcome scores in TKAs implanted using the KA versus an MA technique. The theoretical advantages of improved pain and function that form the basis of the design rationale of KA were not observed in this study. Currently, it is unknown whether the alterations in component alignment seen with KA will compromise long-term survivorship of TKA. In this study, we were unable to demonstrate an advantage to KA in terms of pain or function that would justify this risk. LEVEL OF EVIDENCE: Level I, therapeutic study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
EuroQol: the current state of play
Brooks, R. (1996) · Health Policy · doi:10.1016/0168-8510(96)00822-6 · Cited by 5,815
Rationale, of The Knee Society Clinical Rating System
INSALL, J. N., DORR, L. D., SCOTT, R. D., & NORMAN, W. (1989) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198911000-00004 · Cited by 4,793
The use of the Oxford hip and knee scores
Murray, D. W., Fitzpatrick, R., Rogers, K., Pandit, H., Beard, D. J., Carr, A. J., & Dawson, J. (2007) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.89b8.19424 · Cited by 1,452
Coronal alignment after total knee replacement
Jeffery, R., Morris, R., & Denham, R. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b5.1894655 · Cited by 1,100
Bellemans, J., Colyn, W., Vandenneucker, H., & Victor, J. (2012) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-011-1936-5 · Cited by 1,085
Postoperative Alignment of Total Knee Replacement Its Effect on Survival
RITTER, M. A., FARIS, P. M., KEATING, E. M., & MEDING, J. B. (1994) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199402000-00021 · Cited by 1,008
The “Forgotten Joint” as the Ultimate Goal in Joint Arthroplasty
Behrend, H., Giesinger, K., Giesinger, J. M., & Kuster, M. S. (2012) · The Journal of Arthroplasty · doi:10.1016/j.arth.2011.06.035 · Cited by 857
Parratte, S., Pagnano, M. W., Trousdale, R. T., & Berry, D. J. (2010) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.i.01398 · Cited by 808
Coronal Alignment in Total Knee Arthroplasty
Fang, D. M., Ritter, M. A., & DAVIS, K. E. (2009) · The Journal of Arthroplasty · doi:10.1016/j.arth.2009.04.034 · Cited by 658
Howell, S. M., Howell, S. J., Kuznik, K. T., Cohen, J., & Hull, M. L. (2013) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-012-2613-z · Cited by 495
Cited by
MacDessi, S. J., Griffiths-Jones, W., Harris, I. A., Bellemans, J., & Chen, D. B. (2021) · The Bone & Joint Journal · doi:10.1302/0301-620x.103b2.bjj-2020-1050.r1 · Cited by 738
Blakeney, W., Clément, J., Desmeules, F., Hagemeister, N., Rivière, C., & Vendittoli, P. (2019) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-018-5174-1 · Cited by 198
Winnock de Grave, P., Luyckx, T., Claeys, K., Tampere, T., Kellens, J., Müller, J., & Gunst, P. (2022) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-020-06165-4 · Cited by 174
MacDessi, S. J., Griffiths-Jones, W., Harris, I. A., Bellemans, J., & Chen, D. B. (2020) · Bone & Joint Open · doi:10.1302/2633-1462.17.bjo-2020-0037.r1 · Cited by 136
Griffiths-Jones, W., Chen, D. B., Harris, I. A., Bellemans, J., & MacDessi, S. J. (2021) · Bone & Joint Open · doi:10.1302/2633-1462.25.bjo-2021-0028.r1 · Cited by 103
Metadata
- Authors
- Young, S. W., Walker, M. L., Bayan, A., Briant-Evans, T., Pavlou, P., & Farrington, B.
- Venue
- Clinical Orthopaedics & Related Research
- Published
- 2017-01
- Volume
- 475
- Issue
- 1
- Pages
- 9-20
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2343126763
- Cited by
- 256
- References
- 26
- FWCI
- 27.22
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Chitranjan S. Ranawat Award: No Difference in 2-year Functional Outcomes Using Kinematic versus Mechanical Alignment in TKA: A Randomized Controlled Clinical Trial. https://app.cochat.ai/papers/10.1007/s11999-016-4844-x
- The paper
- Young, S. W., Walker, M. L., Bayan, A., Briant-Evans, T., Pavlou, P., & Farrington, B. (2017). The Chitranjan S. Ranawat Award: No Difference in 2-year Functional Outcomes Using Kinematic versus Mechanical Alignment in TKA: A Randomized Controlled Clinical Trial. Clinical Orthopaedics & Related Research. https://doi.org/10.1007/s11999-016-4844-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.