The DOI matches its Crossref record; 78 of the 78 references it cites were found in a registry or an index.
Luminol-Based Chemiluminescent Signals: Clinical and Non-clinical Application and Future Uses
Open accessAbstract
Chemiluminescence (CL) is an important method for quantification and analysis of various macromolecules. A wide range of CL agents such as luminol, hydrogen peroxide, fluorescein, dioxetanes and derivatives of oxalate, and acridinium dyes are used according to their biological specificity and utility. This review describes the application of luminol chemiluminescence (LCL) in forensic, biomedical, and clinical sciences. LCL is a very useful detection method due to its selectivity, simplicity, low cost, and high sensitivity. LCL has a dynamic range of applications, including quantification and detection of macro and micromolecules such as proteins, carbohydrates, DNA, and RNA. Luminol-based methods are used in environmental monitoring as biosensors, in the pharmaceutical industry for cellular localization and as biological tracers, and in reporter gene-based assays and several other immunoassays. Here, we also provide information about different compounds that may enhance or inhibit the LCL along with the effect of pH and concentration on LCL. This review covers most of the significant information related to the applications of luminol in different fields.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Towbin, H., Staehelin, T., & Gordon, J. (1979) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.76.9.4350 · Cited by 53,385
Raza, H., John, A., & Nemmar, A. (2013) · Cellular Physiology and Biochemistry · doi:10.1159/000350087 · Cited by 47,221
International Journal of Oncology
(2026) · International Journal of Oncology · doi:10.3892/ijo · Cited by 2,331
Teodoro, E.-S., John, B., Mark, C., Max, D., Michael, E., David, A. S., Saul, C.-A., & Nehemias, C.-H. (2006) · Applied Biochemistry and Biotechnology · doi:10.1385/abab:132:1:959 · Cited by 1,113
Enhanced chemiluminescent assay for antioxidant capacity in biological fluids
Whitehead, T. P., Thorpe, G. H. G., & Maxwell, S. R. J. (1992) · Analytica Chimica Acta · doi:10.1016/0003-2670(92)85052-8 · Cited by 354
Forensic application of the luminol reaction as a presumptive test for latent blood detection
Barni, F., Lewis, S. W., Berti, A., Miskelly, G. M., & Lago, G. (2007) · Talanta · doi:10.1016/j.talanta.2006.12.045 · Cited by 342
Luminol chemiluminescence: Chemistry, excitation, emitter
Merényi, G., Lind, J., & Eriksen, T. E. (1990) · Journal of Bioluminescence and Chemiluminescence · doi:10.1002/bio.1170050111 · Cited by 291
Saleh, R. A., Agarwal, A., Kandirali, E., Sharma, R. K., Thomas, A. J., Nada, E. A., Evenson, D. P., & Alvarez, J. G. (2002) · Fertility and Sterility · doi:10.1016/s0015-0282(02)04237-1 · Cited by 259
Ullman, E. F., Kirakossian, H., Switchenko, A. C., Ishkanian, J., Ericson, M., Wartchow, C. A., Pirio, M., Pease, J., Irvin, B. R., Singh, S., et al. (1996) · Clinical Chemistry · doi:10.1093/clinchem/42.9.1518 · Cited by 256
Zhu, X. L., & Sly, W. S. (1990) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)38958-6 · Cited by 243
Self-citationHuang, R.-P., Huang, R., Fan, Y., & Lin, Y. (2001) · Analytical Biochemistry · doi:10.1006/abio.2001.5156 · Cited by 241
Chemiluminescence of LUminol and Related Hydrazides: The Light Emission Step
White, E. H., & Bursey, M. M. (1964) · Journal of the American Chemical Society · doi:10.1021/ja01059a051 · Cited by 240
Chemilunimescence of Luminol: The Chemcial Reaction
White, E. H., Zafiriou, O., Kagi, H. H., & Hill, J. H. M. (1964) · Journal of the American Chemical Society · doi:10.1021/ja01059a050 · Cited by 237
[29] Enhanced chemiluminescent reactions catalyzed by horseradish peroxidase
Thorpe, G. H. G., & Kricka, L. J. (1986) · Methods in Enzymology · doi:10.1016/0076-6879(86)33078-7 · Cited by 227
Lundqvist, H., & Dahlgren, C. (1996) · Free Radical Biology and Medicine · doi:10.1016/0891-5849(95)02189-2 · Cited by 221
Analytical applications of flow injection with chemiluminescence detection—a review
Fletcher, P., Andrew, K. N., Calokerinos, A. C., Forbes, S., & Worsfold, P. J. (2001) · Luminescence · doi:10.1002/bio.607 · Cited by 204
Detection of nitric oxide production from a perfused organ by a luminol-hydrogen peroxide system
Kikuchi, K., Nagano, T., Hayakawa, H., Hirata, Y., & Hirobe, M. (1993) · Analytical Chemistry · doi:10.1021/ac00061a025 · Cited by 193
Detection of multiple proteins in an antibody-based protein microarray system
Huang, R.-P. (2001) · Journal of Immunological Methods · doi:10.1016/s0022-1759(01)00394-5 · Cited by 182
Rose, A. L., & Waite, T. D. (2001) · Analytical Chemistry · doi:10.1021/ac015547q · Cited by 181
Branched DNA amplification multimers for the sensitive, direct detection of human hepatitis viruses.
Urdea, M. S., Horn, T. L., Fultz, T. J., Anderson, M., Running, J. A., Hamren, S., Ahle, D., & Chang, C.-M. (1991) · PubMed · Cited by 171
Cheek, B. J., Steel, A. B., Torres, M. P., Yu, Y., & Yang, H. (2001) · Analytical Chemistry · doi:10.1021/ac0108616 · Cited by 152
Protein Microdeposition Using a Conventional Ink-Jet Printer
Roda, A., Guardigli, M., Russo, C., Pasini, P., & Baraldini, M. (2000) · BioTechniques · doi:10.2144/00283st07 · Cited by 149
[36] The chemiluminescence of luminol and related hydrazides
Roswell, D. F., & White, E. H. (1978) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/0076-6879(78)57038-9 · Cited by 145
Stains, labels and detection strategies for nucleic acids assays
Kricka, L. J. (2002) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/0004563021901865 · Cited by 141
Early diagnosis of Lassa fever by reverse transcription-PCR
Demby, A. H., Chamberlain, J., Brown, D. W., & Clegg, C. S. (1994) · Journal of Clinical Microbiology · doi:10.1128/jcm.32.12.2898-2903.1994 · Cited by 137
Patolsky, F., Weizmann, Y., Katz, E. Y., & Willner, I. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200250379 · Cited by 127
Guan, G., Yang, L., Mei, Q., Zhang, K., Zhang, Z., & Han, M. (2012) · Analytical Chemistry · doi:10.1021/ac302341b · Cited by 124
Chemiluminescent cholesterol sensor based on peroxidase-like activity of cupric oxide nanoparticles
Hong, L., Liu, A., Li, G., Chen, W., & Lin, X. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.11.031 · Cited by 121
Chemiluminescence of luminol catalyzed by silver nanoparticles
Chen, H., Gao, F., He, R., & Cui, D. (2007) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2007.06.052 · Cited by 120
Chemiluminescence and bioluminescence
Kricka, L. J. (1995) · Analytical Chemistry · doi:10.1021/ac00108a035 · Cited by 113
Chemiluminescence and immunoassays
Rongen, H. A. H., Hoetelmans, R. M. W., Bult, A., & Bennekom, W. P. V. (1994) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/0731-7085(94)80027-8 · Cited by 112
Zhang, Y., Pang, L., Ma, C., Tu, Q., Zhang, R., Saeed, E., Mahmoud, A. E., & Wang, J. (2014) · Analytical Chemistry · doi:10.1021/ac404201s · Cited by 112
Microarrays for the Screening of Allergen-Specific IgE in Human Serum
Fall, B. I., Eberlein-König, B., Behrendt, H., Nießner, R., Ring, J., & Weller, M. G. (2002) · Analytical Chemistry · doi:10.1021/ac026016k · Cited by 111
Yamaguchi, M., Yoshida, H., & Nohta, H. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)00004-3 · Cited by 106
Waheed, A. A., Zhu, X. L., & Sly, W. S. (1992) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)50732-3 · Cited by 104
Self-citationFrégeau, C. J., Germain, O., & Fourney, R. (2000) · Journal of Forensic Sciences · doi:10.1520/jfs14688j · Cited by 97
Evaluation of Antioxidant Activity by Chemiluminescence
Hirayama, O., Takagi, M., Hukumoto, K., & Katoh, S. (1997) · Analytical Biochemistry · doi:10.1006/abio.1997.2053 · Cited by 95
Cheng, Y., Yuan, R., Chai, Y., Niu, H., Cao, Y., Liu, H., Bai, L., & Yuan, Y. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.08.010 · Cited by 94
In Vivo Imaging of Inflammatory Phagocytes
Tseng, J., & Kung, A. L. (2012) · Chemistry & Biology · doi:10.1016/j.chembiol.2012.08.007 · Cited by 87
Chemiluminescence: sensitive detection technology for reporter gene assays
Bronstein, I., Martin, C., Fortin, J. J., Olesen, C. E. M., & Voyta, J. C. (1996) · Clinical Chemistry · doi:10.1093/clinchem/42.9.1542 · Cited by 81
Divi, R. L. (2002) · Carcinogenesis · doi:10.1093/carcin/23.12.2043 · Cited by 78
Iron in biology: a structural viewpoint
Lindley, P. F. (1996) · Reports on Progress in Physics · doi:10.1088/0034-4885/59/7/002 · Cited by 74
Bonapace, G., Waheed, A., Shah, G. N., & Sly, W. S. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0404764101 · Cited by 73
Self-citationHomogeneous Assays for Single-Nucleotide Polymorphism Typing Using AlphaScreenPreprint
Beaudet, L., Bédard, J., Breton, B., Mercuri, R. J., & Budarf, M. L. (2001) · Genome Research · doi:10.1101/gr.172501 · Cited by 69
Detection of Metal Ions (Cu2+, Hg2+) and Cocaine by Using Ligation DNAzyme Machinery
Wang, F., Orbach, R., & Willner, I. (2012) · Chemistry - A European Journal · doi:10.1002/chem.201201479 · Cited by 67
Zhou, Z., Yu, Y., & Zhao, Y. (2012) · The Analyst · doi:10.1039/c2an35520e · Cited by 66
Chemiluminescence from the reaction between hypochlorite and luminol
Seitz, W. R. (1975) · The Journal of Physical Chemistry · doi:10.1021/j100569a002 · Cited by 61
Yaqoob, M., Biot, B. F., Nabi, A., & Worsfold, P. J. (2011) · Luminescence · doi:10.1002/bio.1366 · Cited by 54
Huang, Z., Hii, C. S. T., Rathjen, D. A., Poulos, A., Murray, A. W., & Ferrante, A. (1997) · Biochemical Journal · doi:10.1042/bj3250553 · Cited by 53
Lin, Z., Wang, H., Ying, X., Dong, J., Hashi, Y., & Chen, S. (2012) · Food Chemistry · doi:10.1016/j.foodchem.2012.02.161 · Cited by 52
Vesanen, M., Piiparinen, H., Kallio, A., & Vaheri, A. I. (1996) · Journal of Virological Methods · doi:10.1016/0166-0934(95)01991-x · Cited by 51
Serrano, J. M., & Silva, M. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.086 · Cited by 48
Arnhold, J., Mueller, S., Arnold, K., & Grimm, E. (1991) · Journal of Bioluminescence and Chemiluminescence · doi:10.1002/bio.1170060309 · Cited by 48
Miyazawa, T., Suzuki, T., Fujimoto, K., & Kinoshita, M. (1996) · Mechanisms of Ageing and Development · doi:10.1016/0047-6374(95)01687-2 · Cited by 47
Effect of lysophosphatidic acid on motility, polarisation and metabolic burst of human neutrophils
Chettibi, S., Lawrence, A., Stevenson, R. D., & Young, D. (1994) · FEMS Immunology & Medical Microbiology · doi:10.1016/0928-8244(94)90059-0 · Cited by 47
Role of Na+/H+Exchanger Isoform-1 in Human Inflammatory Bowel Disease
Khan, I. U., Siddique, I., Al-Awadi, F. M., & Surapaneni, K. M. (2003) · Canadian Journal of Gastroenterology · doi:10.1155/2003/673819 · Cited by 46
Liu, Y., Fu, Z., & Wang, L. (2010) · Luminescence · doi:10.1002/bio.1243 · Cited by 43
Heart 7-Hydroperoxycholesterol and Oxysterols Are Elevated in Chronically Ethanol-Fed Rats
Adachi, J., Kudo, R., Ueno, Y., Hunter, R., Rajendram, R., Want, E. J., & Preedy, V. R. (2001) · Journal of Nutrition · doi:10.1093/jn/131.11.2916 · Cited by 42
Cao, Y., Yuan, R., Chai, Y., Liu, H., Liao, Y., & Zhuo, Y. (2013) · Talanta · doi:10.1016/j.talanta.2013.03.018 · Cited by 39
[37] Cellular chemiluminescence associated with disease states
Dyke, K. V., & Dyke, C. V. (1986) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/0076-6879(86)33086-6 · Cited by 35
Luminescent immunodetection of Western-blotted proteins from Coomassie-stained polyacrylamide gel
Vachereau, A. (1989) · Analytical Biochemistry · doi:10.1016/0003-2697(89)90227-3 · Cited by 32
Xin, T.-B., Wang, X., Jin, H., Liang, S., Lin, J., & Li, Z. (2008) · Applied Biochemistry and Biotechnology · doi:10.1007/s12010-008-8356-3 · Cited by 32
Li, T., Wang, Z., Xie, H., et al. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2012.10.017 · Cited by 31
Hui, S., Chiba, H., Sakurai, T., ASAKAWA, C., Nagasaka, H., MURAI, T., Ide, H., & KUROSAWA, T. (2007) · Journal of Chromatography B · doi:10.1016/j.jchromb.2007.06.019 · Cited by 29
Vadrot, N., Ghanem, S., Braut‐Boucher, F., Gavrilescu, L., Pilard, N., Mansouri, A., Moreau, R., & Reyl-Desmars, F. (2012) · PLoS ONE · doi:10.1371/journal.pone.0040879 · Cited by 27
Chemiluminescent Detection of Protein Molecular Weight Markers in Western Blot Techniques
Liu, R. H., Jacob, J., & Tennant, B. C. (1997) · BioTechniques · doi:10.2144/97224bm01 · Cited by 26
Chemiluminescent Measurement of Telomere DNA Content in Biopsies
Fordyce, C., Heaphy, C. M., & Griffith, J. K. (2002) · BioTechniques · doi:10.2144/02331md02 · Cited by 26
Luppa, P. B., Brückner, C., Schwab, I., Hauck, S., Schmidmayr, S., Birkmayer, C., Paulus, B., & Hauptmann, H. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.12.2345 · Cited by 26
Chemiluminescence imaging in bioanalysis
Pasini, P., Musiani, M., Russo, C., et al. (1998) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/s0731-7085(98)00209-x · Cited by 25
Luppa, P. B., Brückner, C., Schwab, I., Hauck, S., Schmidmayr, S., Birkmayer, C., Paulus, B., & Hauptmann, H. (1997) · PubMed · Cited by 24
Lin, Z., Sun, X., Lin, Y., & Chen, G. (2013) · The Analyst · doi:10.1039/c3an36503d · Cited by 21
Zang, D., Yan, M., Zhao, P., Ge, L., Liu, S., & Yu, J. (2012) · The Analyst · doi:10.1039/c2an35738k · Cited by 19
Establishment of the optically pumped chemiluminescence technique for diagnostics
Motsenbocker, M. A., Sugawara, T., Shintani, M., MASUYA, H., Ichimori, Y., & Kondo, K. (1993) · Analytical Chemistry · doi:10.1021/ac00052a016 · Cited by 17
Liu, X., Li, A., Zhou, B., Qiu, C., & Ren, H. (2009) · Chemistry Central Journal · doi:10.1186/1752-153x-3-7 · Cited by 17
Microplate analytical method for quinones by pulse photo-irradiation and chemiluminescence detection
Elgawish, M. S., Shimomai, C., Kishikawa, N., Ohyama, K., Nakashima, K., & Kuroda, N. (2012) · The Analyst · doi:10.1039/c2an35353a · Cited by 15
Yang, X., & Zhang, W. (2012) · Luminescence · doi:10.1002/bio.2409 · Cited by 10
Li, X., Zhang, Z., Tao, L., Li, Y., & Li, Y. Y. (2013) · Applied Biochemistry and Biotechnology · doi:10.1007/s12010-013-0345-5 · Cited by 9
Шкапова, Е. А., Kurtasova, L. M., & Савченко, А. А. (2010) · Bulletin of Experimental Biology and Medicine · doi:10.1007/s10517-010-0916-1 · Cited by 7
Cited by
Microfluidic Paper-Based Analytical Devices: From Design to Applications
Noviana, E., Ozer, T., Carrell, C. S., Link, J. S., McMahon, C., Jang, I., & Henry, C. S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01335 · Cited by 631
Depletion of microglia exacerbates postischemic inflammation and brain injury
Jin, W.-N., Shi, S. X.-Y., Li, Z., Li, M., Wood, K., Gonzales, R. J., & Liu, Q. (2017) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x17694185 · Cited by 351
“ROS production was assessed at 24 h after MCAO using luminol as we and others previously described.(42,48) Briefly, mice were injected i.”
Gao, J., Chen, Z., Li, X., Yang, M., Lv, J., Li, H., & Yuan, Z. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms232012556 · Cited by 61
Kwesiga, M. P., Gillette, A. A., Razaviamri, F., Plank, M. E., Canull, A. L., Alesch, Z., He, W., Lee, B. P., & Guillory, R. J. (2023) · Bioactive Materials · doi:10.1016/j.bioactmat.2022.10.017 · Cited by 25
Ximenes, V. F., Ximenes, T. P., Morgon, N. H., & de Souza, A. R. (2021) · Photochemistry and Photobiology · doi:10.1111/php.13410 · Cited by 7
Metadata
- Authors
- Khan, P., Idrees, D., Moxley, M. A., Corbett, J. A., Ahmad, F., von Figura, G., Sly, W. S., Waheed, A., & Hassan, M. I.
- Venue
- Applied Biochemistry and Biotechnology
- Published
- 2014-04-22
- Volume
- 173
- Issue
- 2
- Pages
- 333-355
- ISSN
- 0273-2289 (ISSN-L)
- 1559-0291
- OpenAlex
- W2066499253
- Cited by
- 295
- References
- 78
- FWCI
- 5.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.