Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 264

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Potential benefits of cool roofs on commercial buildings: conserving energy, saving money, and reducing emission of greenhouse gases and air pollutants

Open access
Levinson, Ronnen, Akbari, Hashem · 2010 · Energy Efficiency

Abstract

Cool roofs—roofs that stay cool in the sun by minimizing solar absorption and maximizing thermal emission—lessen the flow of heat from the roof into the building, reducing the need for space cooling energy in conditioned buildings. Cool roofs may also increase the need for heating energy in cold climates. For a commercial building, the decrease in annual cooling load is typically much greater than the increase in annual heating load. This study combines building energy simulations, local energy prices, local electricity emission factors, and local estimates of building density to characterize local, state average, and national average cooling energy savings, heating energy penalties, energy cost savings, and emission reductions per unit conditioned roof area. The annual heating and cooling energy uses of four commercial building prototypes—new office (1980+), old office (pre-1980), new retail (1980+), and old retail (pre-1980)—were simulated in 236 US cities. Substituting a weathered cool white roof (solar reflectance 0.55) for a weathered conventional gray roof (solar reflectance 0.20) yielded annually a cooling energy saving per unit conditioned roof area ranging from 3.30 kWh/m2 in Alaska to 7.69 kWh/m2 in Arizona (5.02 kWh/m2 nationwide); a heating energy penalty ranging from 0.003 therm/m2 in Hawaii to 0.14 therm/m2 in Wyoming (0.065 therm/m2 nationwide); and an energy cost saving ranging from 0.126/m2 in West Virginia to 1.14/m2 in Arizona ( 0.356/m2 nationwide). It also offered annually a CO2 reduction ranging from 1.07 kg/m2 in Alaska to 4.97 kg/m2 in Hawaii (3.02 kg/m2 nationwide); an NOx reduction ranging from 1.70 g/m2 in New York to 11.7 g/m2 in Hawaii (4.81 g/m2 nationwide); an SO2 reduction ranging from 1.79 g/m2 in California to 26.1 g/m2 in Alabama (12.4 g/m2 nationwide); and an Hg reduction ranging from 1.08 μg/m2 in Alaska to 105 μg/m2 in Alabama (61.2 μg/m2 nationwide). Retrofitting 80% of the 2.58 billion square meters of commercial building conditioned roof area in the USA would yield an annual cooling energy saving of 10.4 TWh; an annual heating energy penalty of 133 million therms; and an annual energy cost saving of 735 million. It would also offer an annual CO2 reduction of 6.23 Mt, offsetting the annual CO2 emissions of 1.20 million typical cars or 25.4 typical peak power plants; an annual NOx reduction of 9.93 kt, offsetting the annual NOx emissions of 0.57 million cars or 65.7 peak power plants; an annual SO2 reduction of 25.6 kt, offsetting the annual SO2 emissions of 815 peak power plants; and an annual Hg reduction of 126 kg.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s12053-008-9038-2

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Research works printed but not linked: 7

  1. Akbari, H., Eto, J., Turiel, I., Heinemeier, K., Lebot, B., Nordman, B., & Rainer, L. (1989). Integrated estimation of commercial sector end-use load shapes and energy use intensities (Report No. LBL-27512). Berkeley, CA: Lawrence Berkeley National Laboratory. · doi:10.2172/7260522
  2. Akbari, H., Rainer, L., & Eto, J. (1991). Integrated estimation of commercial sector end-use load shapes and energy use intensities, Phase II (Report No. LBL-30401). Berkeley, CA: Lawrence Berkeley National Laboratory. · doi:10.2172/5297856
  3. Akbari, H., Konopacki, S., Parker, D., Wilcox, B., Eley, C., & Van Geem, M. (1998). Calculations in support of SSP90.1 for reflective roofs. ASHRAE Transactions, 104(1B), 984–995.
  4. Energy Information Administration (EIA) (1979). Commercial buildings consumption and expenditures (nonresidential buildings energy consumption survey). Washington, DC: US Department of Energy.
  5. Energy Information Administration (EIA) (1983). Commercial buildings consumption and expenditures (nonresidential buildings energy consumption survey). Washington, DC: US Department of Energy.
  6. Energy Information Administration (EIA) (1994a). Commercial buildings consumption and expenditures. Washington, DC: US Department of Energy.
  7. Konopacki, S., Akbari, H., Pomerantz, M., Gabersek, S., & Gartland, L. (1997). Cooling energy savings potential of light-colored roofs for residential and commercial buildings in 11 US metropolitan areas (Report No. LBNL-39433). Berkeley, CA: Lawrence Berkeley National Laboratory.

Cited by

See all 264

Metadata

Authors
Levinson, R., & Akbari, H.
Venue
Energy Efficiency
Published
2009-03-14
Volume
3
Issue
1
Pages
53-109
ISSN
  • 1570-646X (ISSN-L)
  • 1570-6478
OpenAlex
W2014997056
Cited by
264
References
6
FWCI
16.48
Type
journal article
Language
en
Open access
hybrid
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Potential benefits of cool roofs on commercial buildings: conserving energy, saving money, and reducing emission of greenhouse gases and air pollutants. https://app.cochat.ai/papers/10.1007/s12053-008-9038-2
The paper
Levinson, R., & Akbari, H. (2010). Potential benefits of cool roofs on commercial buildings: conserving energy, saving money, and reducing emission of greenhouse gases and air pollutants. Energy Efficiency. https://doi.org/10.1007/s12053-008-9038-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.