Changes of hematological and immunological parameters in COVID-19 patients
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The aim of this study was to identify the changes of hematologic and immunological parameters in COVID-19 patients. We collected and analyzed the data of 117 patients who were laboratory confirmed as SARS-CoV-2 infection. The cases were divided into regular group, severe group and critically ill group according to the sixth edition scheme for COVID-19 diagnosis and treatment of China. The laboratory tests included blood routine, cellular and humoral immunity indices, biochemical detections and inflammatory biomarker. Compared with regular patients, severe and critically ill patients had significantly lower lymphocyte count ( p < 0.01), decreased red blood cell and hemoglobin ( p < 0.01), low levels of immunoglobulin G ( p < 0.05) and significantly higher in D-dimer ( p < 0.0001), fibrinogen ( p < 0.01), white blood cell count ( p < 0.01), neutrophil count ( p < 0.0001), interleukin-6 ( p < 0.05), C-reactive protein ( p < 0.01), procalcitonin ( p < 0.01), erythrocyte sedimentation rate ( p < 0.05), ferritin ( p < 0.01) and lactate dehydrogenase ( p < 0.0001). The specific immunoglobulin G antibodies to the SARS-CoV-2 in severe and critically ill patients were significantly lower than that in regular patients ( p < 0.05). Our findings suggest that the lymphocyte counts, red blood cell counts and the immunoglobulin G antibodies of COVID-19 patients were impaired to varying degrees and the blood was in a state of hypercoagulation, which were more obvious in critically ill patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cryo-EM structure of the 2019-nCoV spike in the prefusion conformation
Wrapp, D., Wang, N., Corbett, K. S., Goldsmith, J. A., Hsieh, C.-L., Abiona, O., Graham, B. S., & McLellan, J. S. (2020) · Science · doi:10.1126/science.abb2507 · Cited by 8,897
Pathological findings of COVID-19 associated with acute respiratory distress syndrome
Xu, Z., Shi, L., Wang, Y., Zhang, J., Huang, L., Zhang, C., Liu, S., Zhao, P., Liu, H., Zhu, L., et al. (2020) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(20)30076-x · Cited by 8,545
Chu, H., Zhou, J., Wong, B. H.-Y., Li, C., Chan, J. F.-W., Cheng, Z.-S., Yang, D., Wang, D., Lee, A. C.-Y., Li, C., et al. (2016) · Journal of Infectious Diseases · doi:10.1093/infdis/jiv380 · Cited by 448
Cited by
COVID-19-associated coagulopathy and disseminated intravascular coagulation
Asakura, H., & Ogawa, H. (2021) · International Journal of Hematology · doi:10.1007/s12185-020-03029-y · Cited by 442
Metadata
- Authors
- Yuan, X., Huang, W., Ye, B., Chen, C., Huang, R., Wu, F., Wei, Q., Zhang, W., & Hu, J.
- Venue
- International Journal of Hematology
- Published
- 2020-07-12
- Volume
- 112
- Issue
- 4
- Pages
- 553-559
- ISSN
- 0925-5710 (ISSN-L)
- 1865-3774
- OpenAlex
- W3041173510
- Cited by
- 168
- References
- 3
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Changes of hematological and immunological parameters in COVID-19 patients. https://app.cochat.ai/papers/10.1007/s12185-020-02930-w
- The paper
- Yuan, X., Huang, W., Ye, B., Chen, C., Huang, R., Wu, F., Wei, Q., Zhang, W., & Hu, J. (2020). Changes of hematological and immunological parameters in COVID-19 patients. International Journal of Hematology. https://doi.org/10.1007/s12185-020-02930-w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.