The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Effect of Electromechanical Stimulation on the Maturation of Myotubes on Aligned Electrospun Fibers
Open accessAbstract
Tissue engineering may provide an alternative to cell injection as a therapeutic solution for myocardial infarction. A tissue-engineered muscle patch may offer better host integration and higher functional performance. This study examined the differentiation of skeletal myoblasts on aligned electrospun polyurethane (PU) fibers and in the presence of electromechanical stimulation. Skeletal myoblasts cultured on aligned PU fibers showed more pronounced elongation, better alignment, higher level of transient receptor potential cation channel-1 (TRPC-1) expression, upregulation of contractile proteins and higher percentage of striated myotubes compared to those cultured on random PU fibers and film. The resulting tissue constructs generated tetanus forces of 1.1 mN with a 10-ms time to tetanus. Additional mechanical, electrical, or synchronized electromechanical stimuli applied to myoblasts cultured on PU fibers increased the percentage of striated myotubes from 70 to 85% under optimal stimulation conditions, which was accompanied by an upregulation of contractile proteins such as α-actinin and myosin heavy chain. In describing how electromechanical cues can be combined with topographical cue, this study helped move towards the goal of generating a biomimetic microenvironment for engineering of functional skeletal muscle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Myotubes differentiate optimally on substrates with tissue-like stiffness
Engler, A. J., Griffin, M. A., Sen, S., Bönnemann, C. G., Sweeney, H. L., & Discher, D. E. (2004) · The Journal of Cell Biology · doi:10.1083/jcb.200405004 · Cited by 1,743
Cited by
Qazi, T. H., Mooney, D. J., Pumberger, M., Geißler, S., & Duda, G. N. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.110 · Cited by 433
Conductive biomaterials for muscle tissue engineering
Dong, R., Ma, P. X., & Guo, B. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2019.119584 · Cited by 381
Anisotropic Materials for Skeletal‐Muscle‐Tissue Engineering
Jana, S., Levengood, S. K. L., & Zhang, M. (2016) · Advanced Materials · doi:10.1002/adma.201600240 · Cited by 345
Optogenetic skeletal muscle-powered adaptive biological machines
Raman, R., Cvetkovic, C., Uzel, S. G. M., Platt, R. J., Sengupta, P., Kamm, R. D., & Bashir, R. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1516139113 · Cited by 344
Yang, G., Li, X., He, Y., Ma, J., Ni, G., & Zhou, S. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2017.12.003 · Cited by 336
Metadata
- Authors
- Liao, I.-C., Liu, J. B., Bursac, N., & Leong, K. W.
- Venue
- Cellular and Molecular Bioengineering
- Published
- 2008-09
- Volume
- 1
- Issue
- 2-3
- Pages
- 133-145
- ISSN
- 1865-5025 (ISSN-L)
- 1865-5033
- OpenAlex
- W1985617866
- Cited by
- 164
- References
- 1
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Electromechanical Stimulation on the Maturation of Myotubes on Aligned Electrospun Fibers. https://app.cochat.ai/papers/10.1007/s12195-008-0021-y
- The paper
- Liao, I.-C., Liu, J. B., Bursac, N., & Leong, K. W. (2008). Effect of Electromechanical Stimulation on the Maturation of Myotubes on Aligned Electrospun Fibers. Cellular and Molecular Bioengineering. https://doi.org/10.1007/s12195-008-0021-y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.