Cited by 57Airway Management and Intubation TechniquesTracheal and airway disordersAnesthesia and Sedative Agents

A deliberately restricted laryngeal view with the GlideScope® video laryngoscope is associated with faster and easier tracheal intubation when compared with a full glottic view: a randomized clinical trial

Open access
Gu, Yuqi, Robert, Joshua, Kovacs, George, Milne, Andrew D., Morris, Ian, Hung, Orlando, MacQuarrie, Kirk, Mackinnon, Sean +1 more·2016·Canadian Journal of Anesthesia/Journal canadien d'anesthésie

Abstract

INTRODUCTION: During video laryngoscopy (VL) with angulated or hyper-curved blades, it is sometimes difficult to complete tracheal intubation despite a full view of the larynx. When using indirect VL, it has been suggested that it may be preferable to obtain a deliberately restricted view of the larynx to facilitate passage of the endotracheal tube. We used the GlideScope® GVL video laryngoscope (GVL) to test whether deliberately obtaining a restricted view would result in faster and easier tracheal intubation than with a full view of the larynx. METHODS: We recruited 163 elective surgical patients and randomly allocated the participants to one of two groups: Group F, where a full view of the larynx was obtained and held during GVL-facilitated tracheal intubation, and Group R, with a restricted view of the larynx (< 50% of glottic opening visible). Study investigators experienced in indirect VL performed the intubations. The intubations were recorded and the video recordings were subsequently assessed for total time to intubation, ease of intubation using a visual analogue scale (VAS; where 0 = easy and 100 = difficult), first-attempt success rate, and oxygen saturation after intubation. Complications were also assessed. RESULTS: The median [interquartile range (IQR)] time to intubation was faster in Group R than in Group F (27 [22-36] sec vs 36 [27-48] sec, respectively; median difference, 9 sec; 95% confidence interval [CI], 5 to 13; P < 0.001). The median [IQR] VAS rating for ease of intubation was also better in Group R than in Group F (14 [6-42) mm vs 50 mm [17-65], respectively; median difference, 20 mm; 95% CI, 10 to 31; P < 0.001). There was no difference between groups regarding the first-attempt success rate, oxygen saturation immediately after intubation, or complications. CONCLUSIONS: Using the GVL with a deliberately restricted view of the larynx resulted in faster and easier tracheal intubation than with a full view and with no additional complications. Our study suggests that obtaining a full or Cormack-Lehane grade 1 view may not be desirable when using the GVL. This trial was registered at ClinicalTrials.gov: NCT02144207.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s12630-016-0654-6

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Having a good view with VL does not mean that easy ETI will follow.

    “However, having a good view with VL does not mean that easy ETI will follow.46”

    From Airway Management in Trauma (2018) · cites this paper as [46]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

No references could be resolved yet.

Research works printed but not linked: 23

  1. Apfelbaum JL, Hagberg CA, Caplan RA, et al. Practice guidelines for management of the difficult airway: an updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway. Anesthesiology 2013; 118: 251-70.
  2. Law JA, Broemling N, Cooper RM, et al. The difficult airway with recommendations for management-part 1-difficult tracheal intubation encountered in an unconscious/induced patient. Can J Anesth 2013; 60: 1089-118.
  3. Law JA, Broemling N, Cooper RM, et al. The difficult airway with recommendations for management-part 2-the anticipated difficult airway. Can J Anesth 2013; 60: 1119-38.
  4. Griesdale DE, Liu D, McKinney J, Choi PT. Glidescope(R) video-laryngoscopy versus direct laryngoscopy for endotracheal intubation: a systematic review and meta-analysis. Can J Anesth 2012; 59: 41-52.
  5. Healy DW, Maties O, Hovord D, Kheterpal S. A systematic review of the role of videolaryngoscopy in successful orotracheal intubation. BMC Anesthesiol 2012; 12: 32.
  6. Sun DA, Warriner CB, Parsons DG, Klein R, Umedaly HS, Moult M. The GlideScope video laryngoscope: randomized clinical trial in 200 patients. Br J Anaesth 2005; 94: 381-4.
  7. Walker L, Brampton W, Halai M, et al. Randomized controlled trial of intubation with the McGrath Series 5 videolaryngoscope by inexperienced anaesthetists. Br J Anaesth 2009; 103: 440-5.
  8. Cortellazzi P, Caldiroli D, Byrne A, Sommariva A, Orena EF, Tramacere I. Defining and developing expertise in tracheal intubation using a GlideScope((R)) for anaesthetists with expertise in Macintosh direct laryngoscopy: an in-vivo longitudinal study. Anaesthesia 2015; 70: 290-5.
  9. Aziz MF, Healy D, Kheterpal S, Fu RF, Dillman D, Brambrink AM. Routine clinical practice effectiveness of the Glidescope in difficult airway management: an analysis of 2,004 Glidescope intubations, complications, and failures from two institutions. Anesthesiology 2011; 114: 34-41.
  10. Cooper RM, Pacey JA, Bishop MJ, McCluskey SA. Early clinical experience with a new videolaryngoscope (GlideScope) in 728 patients. Can J Anesth 2005; 52: 191-8.
  11. Dupanovic M, Jensen R. Optimizing GlideScope laryngoscopy: an in vitro study on an airway model. Anesthesiology 2007; 106: 886-8.
  12. Cooper R, Law JA. Rigid and semi-rigid fiberoptic and video laryngoscopy and intubation. In: Hung O, Murhpy MF (Eds). Management of the Difficult and Failed Airway, Second Edition. McGraw-Hill; 2011.
  13. Anderson J, Klock PA Jr. Airway management. Anesthesiol Clin 2014; 32: 445-61.
  14. Levitan RM, Heitz JW, Sweeney M, Cooper RM. The complexities of tracheal intubation with direct laryngoscopy and alternative intubation devices. Ann Emerg Med 2011; 57: 240-7.
  15. Tremblay MH, Williams S, Robitaille A, Drolet P. Poor visualization during direct laryngoscopy and high upper lip bite test score are predictors of difficult intubation with the GlideScope videolaryngoscope. Anesth Analg 2008; 106: 1495-500.
  16. Samsoon GL, Young JR. Difficult tracheal intubation: a retrospective study. Anaesthesia 1987; 42: 487-90.
  17. Levitan RM, Ochroch EA, Kush S, Shofer FS, Hollander JE. Assessment of airway visualization: validation of the percentage of glottic opening (POGO) scale. Acad Emerg Med 1998; 5: 919- 23.
  18. Cormack RS, Lehane J. Difficult tracheal intubation in obstetrics. Anaesthesia 1984; 39: 1105-11.
  19. Datta S, Satten GA. A signed-rank test for clustered data. Biometrics 2008; 64: 501-7.
  20. Reed JF 3rd. Adjusted chi-square statistics: application to clustered binary data in primary care. Ann Fam Med 2004; 2: 201-3.
  21. Siu LW, Mathieson E, Naik VN, Chandra D, Joo HS. Patient-and operator-related factors associated with successful Glidescope intubations: a prospective observational study in 742 patients. Anaesth Intensive Care 2010; 38: 70-5.
  22. Aziz MF, Abrons RO, Cattano D, et al. First-attempt intubation success of video laryngoscopy in patients with anticipated difficult direct laryngoscopy: a multicenter randomized controlled trial comparing the C-MAC D-blade versus the GlideScope in a mixed provider and diverse patient population. Anesth Analg 2016; 122: 740-50.
  23. Radesic BP, Winkelman C, Einsporn R, Kless J. Ease of intubation with the Parker Flex-Tip or a standard Mallinckrodt endotracheal tube using a video laryngoscope (GlideScope). AANA J 2012; 80: 363-72.

Cited by

Sorted by citations

Authors
Gu, Y., Robert, J., Kovacs, G., Milne, A. D., Morris, I., Hung, O., MacQuarrie, K., Mackinnon, S., & Adam Law, J.
Affiliations
Dalhousie University (CA)
Venue
Canadian Journal of Anesthesia/Journal canadien d'anesthésie
Published
2016-04-18
Volume
63
Issue
8
Pages
928-937
ISSN
  • 0832-610X (ISSN-L)
  • 1496-8975
OpenAlex
W2342352320
Cited by
57
References
0
Citations by year
2026: 9 · 2025: 9 · 2024: 5 · 2023: 6 · 2022: 3 · 2021: 5 · 2020: 7 · 2019: 4 · 2018: 4 · 2017: 4 · 2016: 1
FWCI
5.51
Type
journal article
Language
en
Open access
Locations
  • Canadian Journal of Anesthesia/Journal canadien d anesthésie (publishedVersion, other-oa)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Airway Management and Intubation Techniques
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Tracheal and airway disorders
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Anesthesia and Sedative Agents
Keywords
video laryngoscopy, GlideScope, endotracheal intubation, intubation time, first-attempt success rate, intubation complications
MeSH terms
Adult, Aged, Equipment Design, Female, Glottis, Humans, Intubation, Intratracheal, Laryngoscopy, Larynx, Male, Middle Aged, Time, Video Recording, Laryngoscopes

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review