Canadian Airway Focus Group updated consensus-based recommendations for management of the difficult airway: part 1. Difficult airway management encountered in an unconscious patient
Open accessThe DOI matches its Crossref record; 227 of the 227 references it cites were found in a registry or an index.
Abstract
PURPOSE: Since the last Canadian Airway Focus Group (CAFG) guidelines were published in 2013, the literature on airway management has expanded substantially. The CAFG therefore re-convened to examine this literature and update practice recommendations. This first of two articles addresses difficulty encountered with airway management in an unconscious patient. SOURCE: Canadian Airway Focus Group members, including anesthesia, emergency medicine, and critical care physicians, were assigned topics to search. Searches were run in the Medline, EMBASE, Cochrane Central Register of Controlled Trials, and CINAHL databases. Results were presented to the group and discussed during video conferences every two weeks from April 2018 to July 2020. These CAFG recommendations are based on the best available published evidence. Where high-quality evidence was lacking, statements are based on group consensus. FINDINGS AND KEY RECOMMENDATIONS: Most studies comparing video laryngoscopy (VL) with direct laryngoscopy indicate a higher first attempt and overall success rate with VL, and lower complication rates. Thus, resources allowing, the CAFG now recommends use of VL with appropriately selected blade type to facilitate all tracheal intubations. If a first attempt at tracheal intubation or supraglottic airway (SGA) placement is unsuccessful, further attempts can be made as long as patient ventilation and oxygenation is maintained. Nevertheless, total attempts should be limited (to three or fewer) before declaring failure and pausing to consider "exit strategy" options. For failed intubation, exit strategy options in the still-oxygenated patient include awakening (if feasible), temporizing with an SGA, a single further attempt at tracheal intubation using a different technique, or front-of-neck airway access (FONA). Failure of tracheal intubation, face-mask ventilation, and SGA ventilation together with current or imminent hypoxemia defines a "cannot ventilate, cannot oxygenate" emergency. Neuromuscular blockade should be confirmed or established, and a single final attempt at face-mask ventilation, SGA placement, or tracheal intubation with hyper-angulated blade VL can be made, if it had not already been attempted. If ventilation remains impossible, emergency FONA should occur without delay using a scalpel-bougie-tube technique (in the adult patient). The CAFG recommends all institutions designate an individual as "airway lead" to help institute difficult airway protocols, ensure adequate training and equipment, and help with airway-related quality reviews.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–227 of 227
Laryngeal Mask Airway for Cesarean Delivery: A 5-Year Retrospective Cohort Study
Geng, Z.-Y., & Wang, D. (2017) · Chinese Medical Journal · doi:10.4103/0366-6999.199833 · Cited by 21
Radosevich, M. A., Wanta, B. T., Meyer, T. J., Weber, V. W., Brown, D. R., Smischney, N. J., & Diedrich, D. A. (2017) · Journal of Intensive Care Medicine · doi:10.1177/0885066617746089 · Cited by 21
Taneja, S. R., Agarwal, M., Dali, J. S., & Agrawal, G. (2009) · Anaesthesia and Intensive Care · doi:10.1177/0310057x0903700306 · Cited by 20
Metodiev, Y., & Mushambi, M. C. (2020) · British Journal of Anaesthesia · doi:10.1016/j.bja.2020.02.012 · Cited by 20
Beattie, W. S., Culwick, M. D., & Grocott, H. P. (2018) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-018-1141-z · Cited by 19
Peters, J. H., Bruijstens, L. A., van der Ploeg, J., Tan, E. C. T. H., Hoogerwerf, N., & Edwards, M. J. (2014) · Injury · doi:10.1016/j.injury.2014.11.024 · Cited by 19
Vannucci, A., Rossi, I., Prifti, K. K., Kallogjeri, D., Rangrass, G., DeCresce, D., Brenner, D., Lakshman, N., Helsten, D. L., & Cavallone, L. F. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000002659 · Cited by 19
Pieters, B. M., Theunissen, M., & van Zundert, A. A. J. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000002739 · Cited by 18
Ultrasonographic identification of the cricothyroid membrane
Teoh, W. H., & Kristensen, M. S. (2014) · Anaesthesia · doi:10.1111/anae.12735 · Cited by 17
The Ventrain Device: A Future Role in Difficult Airway Algorithms?
Morrison, S. G., Aerts, S., & Saldien, V. (2019) · A&A Practice · doi:10.1213/xaa.0000000000001084 · Cited by 17
Sowers, N., & Kovacs, G. (2016) · The Journal of Emergency Medicine · doi:10.1016/j.jemermed.2015.10.010 · Cited by 14
Self-citationIs it time to revisit tracheal intubation for Cesarean delivery?
Habib, A. S. (2012) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-012-9719-3 · Cited by 14
Raimann, F. J., Dietze, P. E., Cuca, C., Meininger, D., Kessler, P., Byhahn, C., Gill-Schuster, D., Zacharowski, K. D., & Mutlak, H. (2019) · Emergency Medicine International · doi:10.1155/2019/1067473 · Cited by 14
Rozenfeld, R. A., Nannicelli, A. P., Brown, A. R., Eppich, W., Woods, D. M., Lestrud, S. O., Noah, Z., & Holl, J. L. (2016) · Journal of Patient Safety · doi:10.1097/pts.0000000000000272 · Cited by 13
Kovacs, G. J., Duggan, L. V., & Brindley, P. G. (2016) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-016-0804-x · Cited by 13
Self-citationReducing the risk of confirmation bias in unrecognised oesophageal intubation
Jafferji, D., Morris, R., & Levy, N. (2019) · British Journal of Anaesthesia · doi:10.1016/j.bja.2019.01.015 · Cited by 13
Pattison, N. A., Arulkumaran, N., O’Gara, G., Connolly, B. A., Humphreys, S. K., Walsh, T. S., Hopkins, P. A., & Dark, P. M. (2019) · BMJ Open · doi:10.1136/bmjopen-2019-030815 · Cited by 11
Raimann, F. J., Tepperis, D. M., Meininger, D., Zacharowski, K. D., Schalk, R., Byhahn, C., Weber, C. F., & Mutlak, H. (2019) · Emergency Medicine International · doi:10.1155/2019/9690839 · Cited by 11
Yi, I. K., Kwak, H. J., Kim, K. M., Ahn, S. H., Lee, S. Y., & Kim, J. Y. (2019) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.13368 · Cited by 10
The role of an academic emergency department in advancing equity and justice
Landry, A., Brown, I., Blomkalns, A. L., & Wolfe, R. E. (2020) · Academic Emergency Medicine · doi:10.1111/acem.14164 · Cited by 9
Humphreys, S. R., von Ungern-Sternberg, B. S., Skowno, J., et al. (2019) · BMJ Open · doi:10.1136/bmjopen-2019-031873 · Cited by 8
Airway management guidelines: A safe passage to India
Ramkumar, V., & Divatia, J. (2016) · Indian Journal of Anaesthesia · doi:10.4103/0019-5049.195480 · Cited by 8
BET 2: should real resuscitationists use airway checklists?
Hardy, G., & Horner, D. (2016) · Emergency Medicine Journal · doi:10.1136/emermed-2016-205871.2 · Cited by 7
Difficultintubationapp.com – A difficult airway electronic record
Shanahan, E., Huang, J. H.-C., Chen, A., Narsimhan, A., & Tang, R. (2016) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-016-0723-x · Cited by 6 · cited 1×
“In the future, it may be possible to routinely add photos or recordings of VL to the EMR, or for the patient to use secure, app-based technology to store or access their own airway-related information.(291)”
Malpas, G. A., Kovacs, G. J., Mackinnon, S. P., Hung, O. R., Phipps, S. J., & Law, J. A. (2020) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-020-01647-y · Cited by 5
Self-citationTurkstra, T. P., Turkstra, D. C., Pavlosky, A., & Jones, P. M. (2020) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-020-01778-2 · Cited by 3
Self-citationMakris, M., Harrop‐Griffiths, W., & Cook, T. M. (2013) · Anaesthesia · doi:10.1111/anae.12507 · Cited by 2
Cited by
Law, J. A., Duggan, L. V., Asselin, M., Baker, P., Crosby, E., Downey, A., Hung, O. R., Kovacs, G., Lemay, F., Noppens, R., et al. (2021) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-021-02008-z · Cited by 203
Self-citationManagement of the Difficult Airway
(2021) · New England Journal of Medicine · doi:10.1056/nejmc2109513 · Cited by 8
Metadata
- Authors
- Law, J. A., Duggan, L. V., Asselin, M., Baker, P., Crosby, E., Downey, A., Hung, O. R., Jones, P. M., Lemay, F., Noppens, R., Parotto, M., Preston, R., Sowers, N., Sparrow, K., Turkstra, T. P., Wong, D. T., Kovacs, G., & for the Canadian Airway Focus Group
- Venue
- Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Published
- 2021-06-18
- Volume
- 68
- Issue
- 9
- Pages
- 1373-1404
- ISSN
- 0832-610X (ISSN-L)
- 1496-8975
- OpenAlex
- W3168446116
- Cited by
- 184
- References
- 227
- FWCI
- 27.30
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.