CoChat

Characterization of domestic gray water from point source to determine the potential for urban residential reuse: a short review

Open access
Edwin, Golda A., Gopalsamy, Poyyamoli, Muthu, Nandhivarman · 2014 · Applied Water Science

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Abstract

This study aims to discern the domestic gray water (GW) sources that is least polluting, at the urban households of India, by examining the GW characteristics, comparing with literature data, reuse standards and suitable treatment technologies. In view of this, the quantitative and qualitative characteristics of domestic GW originating from bath, wash basin, laundry and kitchen sources are determined and compared with established standards for reuse requirements. Quality of different gray water sources is characterized with respect to the physical, chemical, biological, nutrient, ground element and heavy metal properties. The pollutant loads indicate that the diversion techniques are not suitable for household application and, therefore, treatment is necessary prior to storage and reuse. It is observed that the total volume of GW generated exceeds the reuse requirement for suggested reuse such as for flushing and gardening/irrigation. In spite of generating less volume, the kitchen source is found to be the major contributor for most of the pollutant load and, therefore, not recommended to be considered for treatment. It is concluded that treatment of GW from bathroom source alone is sufficient to meet the onsite reuse requirements and thereby significantly reduce the potable water consumption by 28.5 %. Constructed wetland systems and constructed soil filters are suggested as suitable treatment alternatives owing to its ability to treat highly variable pollutant load with lower operational and maintenance cost, which is more practical for tropical and developing countries.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s13201-013-0128-8

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Figures

Image 1
CC-BY · From the PDF
Fig. 1 The relative distribution of total water consumption and GW production
Fig. 1 The relative distribution of total water consumption and GW productionCC-BY · From the PDF
Fig. 2 The relative pollutant load in gray from different point of origination
Fig. 2 The relative pollutant load in gray from different point of originationCC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 30 references

Research works printed but not linked: 8

  1. APHA (2005) Standard methods for the examination of water and waste water. American Public Health Association, 21st edition. Washington
  2. Metcalf and Eddy, Inc., McGraw-Hill, New York
  3. CPCB (2008) Performance of sewage treatment plants-coliform reduction. Central Pollution Control Board. Ministry of Envi- ronment and Forests, New Delhi
  4. Hanson L (1997) Environmentally friendly systems and products: water saving devices. Department of Environment, Transport and the Regions, Bracknell: BSRIA
  5. Kadewa WW (2010) Small-scale constructed wetland for onsite light gray water treatment and recycling Kambanellas CA (1998) Recycling of gray water in Cyprus. Water Development Department, Nicosia
  6. NEERI (2007a) Guidance manual for water quality monitoring and assessment (First Edition), October 2007. National Environmental Engineering Research Institute (Neeri), Nehru Marg, Nagpur
  7. NEERI (2007b) Guidance manual gray water reuse in rural Schools. National Environmental Engineering Research Institute, India
  8. NEERI (2007a) Guidance manual for water quality monitoring and assessment (First Edition), October 2007. National Environmen- tal Engineering Research Institute (Neeri), Nehru Marg, Nagpur NEERI (2007b) Guidance manual gray water reuse in rural Schools. National Environmental Engineering Research Institute, India NSW (2007) New South Wales Government. NSW guidelines for gray water reuse in sewered, single household residential premises. Department of Energy Utilities and Sustainability, Sydney

Cited by

See all 109

Metadata

Authors
Edwin, G. A., Gopalsamy, P., & Muthu, N.
Affiliations
Pondicherry University (IN)
Corresponding author
Edwin, Golda A.
Venue
Applied Water Science
Published
2013-09-26
Volume
4
Issue
1
Pages
39-49
ISSN
  • 2190-5487 (ISSN-L)
  • 2190-5495
OpenAlex
W1978830737
Cited by
107
References
30
Citations by year
2026: 6 · 2025: 15 · 2024: 14 · 2023: 16 · 2022: 8 · 2021: 14 · 2020: 14 · 2019: 7 · 2018: 7 · 2017: 2 · 2016: 3 · 2014: 1
FWCI
2.28
Type
journal article
Language
en
Open access
Locations
Applied Water Science (publishedVersion, cc-by)
Funders
  • Ministry of Environment
  • Wageningen University and Research
Topics
  • Physical Sciences › Environmental Science › Waste Management and Disposal › Wastewater Treatment and Reuse
  • Physical Sciences › Environmental Science › Environmental Engineering › Urban Stormwater Management Solutions
  • Physical Sciences › Environmental Science › Waste Management and Disposal › Constructed Wetlands for Wastewater Treatment
Keywords
pollutant load, heavy metals, nutrients, potable water conservation, constructed wetlands, India

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Characterization of domestic gray water from point source to determine the potential for urban residential reuse: a short review. https://app.cochat.ai/papers/10.1007/s13201-013-0128-8
The paper
Edwin, G. A., Gopalsamy, P., & Muthu, N. (2014). Characterization of domestic gray water from point source to determine the potential for urban residential reuse: a short review. Applied Water Science. https://doi.org/10.1007/s13201-013-0128-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.