The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Biosensors: frontiers in rapid detection of COVID-19
Open accessAbstract
The rapid community-spread of novel human coronavirus 2019 (nCOVID19 or SARS-Cov2) and morbidity statistics has put forth an unprecedented urge for rapid diagnostics for quick and sensitive detection followed by contact tracing and containment strategies, especially when no vaccine or therapeutics are known. Currently, quantitative real-time polymerase chain reaction (qRT-PCR) is being used widely to detect COVID-19 from various types of biological specimens, which is time-consuming, labor-intensive and may not be rapidly deployable in remote or resource-limited settings. This might lead to hindrance in acquiring realistic data of infectivity and community spread of SARS-CoV-2 in the population. This review summarizes the existing status of current diagnostic methods, their possible limitations, and the advantages of biosensor-based diagnostics over the conventional ones for the detection of SARS-Cov-2. Novel biosensors used to detect RNA-viruses include CRISPR-Cas9 based paper strip, nucleic-acid based, aptamer-based, antigen-Au/Ag nanoparticles-based electrochemical biosensor, optical biosensor, and Surface Plasmon Resonance. These could be effective tools for rapid, authentic, portable, and more promising diagnosis in the current pandemic that has affected the world economies and humanity. Present challenges and future perspectives of developing robust biosensors devices for rapid, scalable, and sensitive detection and management of COVID-19 are presented in light of the test-test-test theme of the World Health Organization (WHO).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Label-Free Plasmonic Biosensors for Point-of-Care Diagnostics: A Review
Soler, M., Huertas, C. S., & Lechuga, L. M. (2019) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2019.1554435 · Cited by 236
Cited by
Fritea, L., Banica, F., Costea, T., Moldovan, L., Dobjanschi, L., Muresan, M., & Cavalu, S. (2021) · Materials · doi:10.3390/ma14216319 · Cited by 311
Narita, F., Wang, Z., Kurita, H., Li, Z., Shi, Y., Jia, Y., & Soutis, C. (2021) · Advanced Materials · doi:10.1002/adma.202005448 · Cited by 263
Metadata
- Authors
- Samson, R., Navale, G. R., & Dharne, M. S.
- Venue
- 3 Biotech
- Published
- 2020-08-11
- Volume
- 10
- Issue
- 9
- Pages
- 385-385
- ISSN
- 2190-572X (ISSN-L)
- 2190-5738
- OpenAlex
- W3047756296
- Cited by
- 186
- References
- 1
- FWCI
- 4.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biosensors: frontiers in rapid detection of COVID-19. https://app.cochat.ai/papers/10.1007/s13205-020-02369-0
- The paper
- Samson, R., Navale, G. R., & Dharne, M. S. (2020). Biosensors: frontiers in rapid detection of COVID-19. 3 Biotech. https://doi.org/10.1007/s13205-020-02369-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.