Multiple Aneurysms AnaTomy CHallenge 2018 (MATCH): Phase I: Segmentation
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
Purpose Advanced morphology analysis and image-based hemodynamic simulations are increasingly used to assess the rupture risk of intracranial aneurysms (IAs). However, the accuracy of those results strongly depends on the quality of the vessel wall segmentation.Methods To evaluate state-of-the-art segmentation approaches, the Multiple Aneurysms AnaTomy CHallenge (MATCH) was announced. Participants carried out segmentation in three anonymized 3D DSA datasets (left and right anterior, posterior circulation) of a patient harboring five IAs. Qualitative and quantitative inter-group comparisons were carried out with respect to aneurysm volumes and ostia. Further, over- and undersegmentation were evaluated based on highly resolved 2D images. Finally, clinically relevant morphological parameters were calculated.Results Based on the contributions of 26 participating groups, the findings reveal that no consensus regarding segmentation software or underlying algorithms exists. Qualitative similarity of the aneurysm representations was obtained. However, inter-group differences occurred regarding the luminal surface quality, number of vessel branches considered, aneurysm volumes (up to 20%) and ostium surface areas (up to 30%). Further, a systematic oversegmentation of the 3D surfaces was observed with a difference of approximately 10% to the highly resolved 2D reference image. Particularly, the neck of the ruptured aneurysm was overrepresented by all groups except for one. Finally, morphology parameters (e.g., undulation and non-sphericity) varied up to 25%.Conclusions MATCH provides an overview of segmentation methodologies for IAs and highlights the variability of surface reconstruction. Further, the study emphasizes the need for careful processing of initial segmentation results for a realistic assessment of clinically relevant morphological parameters.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
A method for registration of 3-D shapes
Besl, P. J., & McKay, N. D. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.121791 · Cited by 18,103
Object modelling by registration of multiple range images
Chen, Y., & Medioni, G. (1992) · Image and Vision Computing · doi:10.1016/0262-8856(92)90066-c · Cited by 3,154
The Physiological Principle of Minimum Work: I. The Vascular System and the Cost of Blood Volume
Murray, C. D. (1926) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.12.3.207 · Cited by 2,087
Meng, H., Tutino, V. M., Xiang, J., & Siddiqui, A. (2014) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3558 · Cited by 955
An image-based modeling framework for patient-specific computational hemodynamics
Antiga, L., Piccinelli, M., Botti, L., Ene-Iordache, B., Remuzzi, A., & Steinman, D. A. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0420-1 · Cited by 850
Hemodynamic–Morphologic Discriminants for Intracranial Aneurysm Rupture
Xiang, J., Natarajan, S. K., Tremmel, M., Ma, D., Mocco, J., Hopkins, L. N., Siddiqui, A. H., Levy, E. I., & Meng, H. (2011) · Stroke · doi:10.1161/strokeaha.110.592923 · Cited by 782
MORPHOLOGY PARAMETERS FOR INTRACRANIAL ANEURYSM RUPTURE RISK ASSESSMENT
Dhar, S., Tremmel, M., Mocco, J., Kim, M., Yamamoto, J., Siddiqui, A. H., Hopkins, L. N., & Meng, H. (2008) · Neurosurgery · doi:10.1227/01.neu.0000316847.64140.81 · Cited by 589
Cebral, J. R., Mut, F., Weir, J., & Putman, C. (2011) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2419 · Cited by 470
Quantified aneurysm shape and rupture risk
Raghavan, M. L., Ma, B., & Harbaugh, R. E. (2005) · Journal of Neurosurgery · doi:10.3171/jns.2005.102.2.0355 · Cited by 413
Cebral, J. R., Mut, F., Raschi, M., Scrivano, E., Ceratto, R., Lylyk, P., & Putman, C. M. (2011) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2398 · Cited by 390
Cited by
Li, G., Wang, H., Zhang, M., Tupin, S., Qiao, A., Liu, Y., Ohta, M., & Anzai, H. (2021) · Communications Biology · doi:10.1038/s42003-020-01638-1 · Cited by 165
Computational fluid dynamics as a risk assessment tool for aneurysm rupture
Murayama, Y., Fujimura, S., Suzuki, T., & Takao, H. (2019) · Neurosurgical FOCUS · doi:10.3171/2019.4.focus19189 · Cited by 113
Berg, P., Saalfeld, S., Voß, S., Beuing, O., & Janiga, G. (2019) · Neurosurgical FOCUS · doi:10.3171/2019.4.focus19181 · Cited by 103
Self-citationSteinman, D. A., & Pereira, V. M. (2019) · Neurosurgical FOCUS · doi:10.3171/2019.4.focus19123 · Cited by 73
Steinman, D. A., & Migliavacca, F. (2018) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-018-00393-z · Cited by 71
Association between aneurysm hemodynamics and wall enhancement on 3D vessel wall MRI
Khan, M. O., Arana, V. T., Rubbert, C., Cornelius, J. F., Fischer, I., Bostelmann, R., Mijderwijk, H.-J., Turowski, B., Steiger, H., May, R., et al. (2020) · Journal of neurosurgery · doi:10.3171/2019.10.jns191251 · Cited by 60
Credibility assessment of in silico clinical trials for medical devices
Pathmanathan, P., Aycock, K., Badal, A., Bighamian, R., Bodner, J., Craven, B. A., & Niederer, S. (2024) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1012289 · Cited by 62
“For such PSMs, it is important to confirm that outputs of the model are not impacted by inter-or intra-user variability [9,48,51,52].”
He, Y., Northrup, H. M., Le, H., Cheung, A. K., Berceli, S. A., & Shiu, Y.-T. E. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.855791 · Cited by 60
“The variation of lumen segmentation algorithms of fi ve intracranial aneurysms from 3D digital subtraction angiography (DSA) images among the 26 participating groups has been assessed (Berg et al., 2018).”
MethodBlood flow analysis with computational fluid dynamics and 4D-flow MRI for vascular diseases
Kamada, H., Nakamura, M., Ota, H., Higuchi, S., & Takase, K. (2022) · Journal of Cardiology · doi:10.1016/j.jjcc.2022.05.007 · Cited by 59
Hemodynamics of Cerebral Aneurysms: Connecting Medical Imaging and Biomechanical Analysis
Rayz, V. L., & Cohen‐Gadol, A. (2020) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-092419-061429 · Cited by 59
Larsen, N., Flüh, C., Saalfeld, S., Voß, S., Hille, G., Trick, D., Wodarg, F., Synowitz, M., Jansen, O., & Berg, P. (2020) · Neuroradiology · doi:10.1007/s00234-020-02498-6 · Cited by 49
“Additionally, an overestimation of the neck size using 3D imaging techniques can occur compared with 2D images, but careful segmentation using advanced algorithms was applied [44, 45].”
MethodSelf-citationMultiple Aneurysms AnaTomy CHallenge 2018 (MATCH)—phase II: rupture risk assessment
Berg, P., Voß, S., Janiga, G., Saalfeld, S., Bergersen, A. W., Valen‐Sendstad, K., Brüning, J., Goubergrits, L., Spuler, A., Chiu, T. L., et al. (2019) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-019-01986-2 · Cited by 42
Self-citationKhan, M. O., Arana, V. T., Najafi, M., MacDonald, D. E., Natarajan, T., Valen‐Sendstad, K., & Steinman, D. A. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110683 · Cited by 39
Deep learning-based recognition and segmentation of intracranial aneurysms under small sample size
Zhu, G., Luo, X., Yang, T., Cai, L., Yeo, J. H., Yan, G., & Yang, J. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.1084202 · Cited by 39
“Inaccurate segmentation (especially for important anatomical features, such as aneurysm necks) may result in unrealistic fl ow patterns and diverging fl ow parameter values and therefore may even lead to erroneous conclusions (Berg et al., 2018, 2019; Valen-Sendstad et al., 2018).”
ResultSaalfeld, S., Voß, S., Beuing, O., Preim, B., & Berg, P. (2019) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-019-02036-7 · Cited by 35
Self-citationComputational Hemodynamic Modeling of Arterial Aneurysms: A Mini-Review
Lipp, S. N., Niedert, E. E., Cebull, H. L., Diorio, T. C., Ma, J. L., Rothenberger, S. M., Stevens, K. A., & Goergen, C. J. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.00454 · Cited by 40
Mesh neural networks for SE(3)-equivariant hemodynamics estimation on the artery wall
Suk, J., de Haan, P., Lippe, P., Brüne, C., & Wolterink, J. M. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108328 · Cited by 56
Multiple Aneurysms AnaTomy CHallenge 2018 (MATCH)—Phase Ib: Effect of morphology on hemodynamics
Voß, S., Beuing, O., Janiga, G., & Berg, P. (2019) · PLoS ONE · doi:10.1371/journal.pone.0216813 · Cited by 34
Self-citationPravdivtseva, M., Peschke, E., Lindner, T., Wodarg, F., Hensler, J., Gabbert, D. D., Voges, I., Berg, P., Barker, A. J., Jansen, O., et al. (2021) · Medical Physics · doi:10.1002/mp.14714 · Cited by 33
Self-citationParitala, P. K., Anbananthan, H., Hautaniemi, J., Smith, M., George, A., Allenby, M. C., Mendieta, J. B., Wang, J., Maclachlan, L., Liang, E. S., et al. (2023) · Scientific Reports · doi:10.1038/s41598-022-27354-w · Cited by 33
Intracranial aneurysm growth: consistency of morphological changes
Leemans, E. L., Cornelissen, B. M. W., Said, M., van den Berg, R., Slump, C. H., Marquering, H. A., & Majoie, C. B. L. M. (2019) · Neurosurgical FOCUS · doi:10.3171/2019.4.focus1987 · Cited by 32
Cancelliere, N. M., Najafi, M., Brina, O., Bouillot, P., Vargas, M. I., Lövblad, K., Krings, T., Pereira, V. M., & Steinman, D. A. (2019) · Journal of NeuroInterventional Surgery · doi:10.1136/neurintsurg-2019-015389 · Cited by 29
Song, M., Wang, S., Qian, Q., Zhou, Y., Luo, Y., & Gong, X. (2024) · Scientific Data · doi:10.1038/s41597-024-04056-8 · Cited by 32
Najafi, M., Cancelliere, N. M., Brina, O., Bouillot, P., Vargas, M. I., Delattre, B. M. A., Pereira, V. M., & Steinman, D. A. (2020) · Journal of NeuroInterventional Surgery · doi:10.1136/neurintsurg-2020-015993 · Cited by 26
Iosif, C., & Biondi, A. (2019) · Expert Review of Medical Devices · doi:10.1080/17434440.2019.1575725 · Cited by 25
“investigate specific regions of interest of the aneurysm and to try to predict the hemodynamic impact on its behavior [116,117].”
BackgroundIvantsits, M., Goubergrits, L., Kuhnigk, J., Hüllebrand, M., Brüning, J., Kossen, T., Pfahringer, B., Schaller, J., Spuler, A., Kühne, T., et al. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.102333 · Cited by 30
Khalili, E., Daversin, C., Olivares, A. L., Mill, J., Cámara, Ó., & Valen‐Sendstad, K. (2024) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3804 · Cited by 23
“59 However, assessing such errors is beyond the scope of the current study.”
BackgroundSouche, A., & Valen‐Sendstad, K. (2022) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2022.111369 · Cited by 22
Review of CFD Based Simulations to Study the Hemodynamics of Cerebral Aneurysms
Maramkandam, E. B., Kannan, A., Valeti, C., Manjunath, N., Panneerselvam, N. K., Alagan, A. K., Panchal, P. M., Kannath, S. K., Darshan, H. R., Nekkanti, R. K., et al. (2024) · Journal of the Indian Institute of Science · doi:10.1007/s41745-024-00431-x · Cited by 28
“There are several aspects of CFD simulations which can cause variability among research groups 82,83 .”
Zhang, M., Peng, F., Li, Y., He, L., Liu, A., & Li, R. (2020) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-20-440 · Cited by 20
“It has several disadvantages, including: (I) simulation modeling is hypothetical and uncertain (37); (II) low sensitivity of reconstructed geometry to imaging modality (38); (III) segmentation variability (39); and (VI) unrealistic modeling of flow data (10).”
BackgroundmorphMan: Automated manipulation of vascular geometries
Kjeldsberg, H. A., Bergersen, A. W., & Valen‐Sendstad, K. (2019) · The Journal of Open Source Software · doi:10.21105/joss.01065 · Cited by 18
“To use realistic geometries we could instead correlate the shape and computed stresses based on hundreds of patient-specific models, but this is very labor intensive and error-prone (Berg et al., 2018; Valen-Sendstad et al., 2018).”
MethodShimano, K., Serigano, S., Ikeda, N., Yuchi, T., Shiratori, S., & Nagano, H. (2019) · Journal of Biorheology · doi:10.17106/jbr.33.32 · Cited by 14
Korte, J., Voß, S., Janiga, G., Beuing, O., Behme, D., Saalfeld, S., & Berg, P. (2023) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-023-00675-1 · Cited by 16
Self-citationVardhan, M., & Randles, A. P. (2021) · Biophysics Reviews · doi:10.1063/5.0040315 · Cited by 23
AnXplore: a comprehensive fluid-structure interaction study of 101 intracranial aneurysms
Goetz, A., Rico, P. J., Pelissier, U., Chau, Y., Sédat, J., & Hachem, E. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1433811 · Cited by 27
Goubergrits, L., Hellmeier, F., Brüning, J., Spuler, A., Hege, H., Voß, S., Janiga, G., Saalfeld, S., Beuing, O., & Berg, P. (2019) · BioMedical Engineering OnLine · doi:10.1186/s12938-019-0657-y · Cited by 15
Self-citationAbdelsamie, A. H., Voß, S., Berg, P., Chi, C., Arens, C., Thévenin, D., & Janiga, G. (2023) · Computers & Fluids · doi:10.1016/j.compfluid.2023.105819 · Cited by 14
Self-citationNiemann, A., Behme, D., Larsen, N., Preim, B., & Saalfeld, S. (2023) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-022-02818-6 · Cited by 14
van de Velde, L., Jebbink, E. G., Hagmeijer, R., Versluis, M., & Reijnen, M. M. P. J. (2022) · Journal of Endovascular Therapy · doi:10.1177/15266028221091890 · Cited by 11
Bergersen, A. W., Kjeldsberg, H. A., & Valen‐Sendstad, K. (2020) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3330 · Cited by 11
“Furthermore, segmentation has been shown to be a labor-intensive and error-prone process.(14,15) On the other hand, idealized models have the advantage of a parametric, objective, and isolated modification of morphological features.”
BackgroundRico, P. J., Goetz, A., Méliga, P., Larcher, A., Özpeynirci, Y., & Hachem, E. (2023) · Fluids · doi:10.3390/fluids9010001 · Cited by 10
Kalajahi, A. P., Csala, H., Mamun, Z. B., Yadav, S., Amili, O., Arzani, A., & D’Souza, R. M. (2025) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2025.110600 · Cited by 9
Thiyagarajah, N., Achey, R., Rashidi, M., & Moore, N. Z. (2022) · Journal of Engineering and Science in Medical Diagnostics and Therapy · doi:10.1115/1.4053943 · Cited by 9
An Automated Workflow for Hemodynamic Computations in Cerebral Aneurysms
Nita, C., Suzuki, T., Lucian Mihai, I. T. U., Mihalef, V., Takao, H., Murayama, Y., Sharma, P. K., Redel, T., & Rapaka, S. (2020) · Computational and Mathematical Methods in Medicine · doi:10.1155/2020/5954617 · Cited by 9
Swiatek, V. M., Voß, S., Sprenger, F., Fischer, I., Kader, H., Stein, K., Schwab, R., Saalfeld, S., Rashidi, A., Behme, D., et al. (2025) · Scientific Reports · doi:10.1038/s41598-025-08478-1 · Cited by 8
“Accurate morphological evaluation is further important because it directly impacts the reliability of hemodynamic simulations, which are essential for understanding aneurysm pathophysiology 17–22 .”
Self-citationThormann, M., Stahl, J., Marsh, L. M. M., Saalfeld, S., Sillis, N., Ding, A., Mpotsaris, A., Berg, P., & Behme, D. (2024) · Fluids · doi:10.3390/fluids9030055 · Cited by 6
“Simulation may assist device selection by fully exploiting FDs’ intra-aneurysmal hemodynamic effects.”
BackgroundSelf-citationOn flow fluctuations in ruptured and unruptured intracranial aneurysms: resolved numerical study
Huang, F., Janiga, G., Berg, P., & Hosseini, S. A. (2024) · Scientific Reports · doi:10.1038/s41598-024-70340-7 · Cited by 6
Self-citationStahl, J., McGuire, L. S., Abou‐Mrad, T., Saalfeld, S., Behme, D., Alaraj, A. M., & Berg, P. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14082638 · Cited by 6
“Aiming at a realistic hemodynamic prediction, patient-specific flow values were applied as boundary conditions using the QMRA flow measurements for each case.”
Self-citationImage-based hemodynamic simulations for intracranial aneurysms: the impact of complex vasculature
Gaidzik, F., Korte, J., Saalfeld, S., Janiga, G., & Berg, P. (2024) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-023-03045-3 · Cited by 6
Self-citationThe influence of blood velocity and vessel geometric parameters on wall shear stress
Pan, F., Mori, N., Mugikura, S., Ohta, M., & Anzai, H. (2024) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2024.104112 · Cited by 6
Impact of workflow variability on image-based intracranial aneurysm hemodynamics
Voß, S., Niemann, U., Saalfeld, S., Janiga, G., & Berg, P. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110018 · Cited by 6
Self-citationLiu, X., Kao, E., Haraldsson, H., Ballweber, M., Martin, A. J., Li, Y., Wang, Y., & Saloner, D. (2021) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-021-00917-0 · Cited by 6
“The error in geometry segmentation and its effect on hemodynamics has been explored elsewhere [10, 11].”
BackgroundIntegrated Image-Based Computational Fluid Dynamics Modeling Software as an Instructional Tool
Stevens, K. A., Dong, M. L., Oakes, J. M., Bellini, C. M., Rayz, V. L., LaDisa, J. F., Parker, D., Wilson, N. M., Shadden, S. C., Marsden, A. L., et al. (2020) · Journal of Biomechanical Engineering · doi:10.1115/1.4047479 · Cited by 5
Challenges in Modeling Hemodynamics in Cerebral Aneurysms Related to Arteriovenous Malformations
Stevens, K. A., Shidhore, T. C., Cohen‐Gadol, A., Christov, I. C., & Rayz, V. L. (2022) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-022-00609-3 · Cited by 5
Aneurysm Neck Overestimation has a Relatively Modest Impact on Simulated Hemodynamics
MacDonald, D. E., Cancelliere, N. M., Pereira, V. M., & Steinman, D. A. (2022) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-022-00652-0 · Cited by 5
“In [7], the authors evaluated the sensitivity of aneurysm segmentation to DSA kernel reconstruction choice, demonstrating changes in neck width and in resulting CFD-derived hemodynamic parameters.”
BackgroundComparison of Manual versus Semi-Automatic Segmentations of the Stenotic Carotid Artery Bifurcation
Csippa, B., Mihály, Z., Czinege, Z., Németh, M. B., Halász, G., Paál, G., & Sótonyi, P. (2021) · Applied Sciences · doi:10.3390/app11178192 · Cited by 4
“For the sake of convenience, shading is the same as in [24].”
BackgroundPerez‐Raya, I., Fathi, M. F., Baghaie, A., Sacho, R. H., & D’Souza, R. M. (2021) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-020-00511-w · Cited by 4
Totorean, A. F., Bernad, S. I., Ciocan, T., Totorean, I.-C., & Bernad, E. S. (2022) · Forum for interdisciplinary mathematics · doi:10.1007/978-981-19-1438-6_1 · Cited by 6
Hellmeier, F., Brüning, J., Berg, P., Saalfeld, S., Spuler, A., Sandalcioglu, I. E., Beuing, O., Larsen, N., Schaller, J., & Goubergrits, L. (2022) · BMJ Open · doi:10.1136/bmjopen-2022-063051 · Cited by 4
Self-citationInfluence of different outflow boundary conditions on hemodynamic analysis of cerebral aneurysm
Makino, S., Shimano, K., Shiratori, S., Nagano, H., & Ujiié, H. (2023) · Journal of Biorheology · doi:10.17106/jbr.37.21 · Cited by 4
Chen, B., Huang, S., Zhang, L., Yang, L., Liu, Y., & Li, C. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1157787 · Cited by 3
Uchikawa, H., Kin, T., Takeda, Y., Koike, T., Kiyofuji, S., Koizumi, S., Shiode, T., Suzuki, Y., Miyawaki, S., Nakatomi, H., et al. (2021) · World Neurosurgery X · doi:10.1016/j.wnsx.2021.100098 · Cited by 3
“Various temporary parameter settings are needed for analysis with CFD, but the methods differ for each facility, sometimes leading to different results.(20,21) In addition, it might not reflect accurate hemodynamics because problems, such as blood-wall interaction, have not been technically solved.”
MethodMacDonald, D. E., Cancelliere, N. M., Rustici, A., Pereira, V. M., & Steinman, D. A. (2022) · Journal of NeuroInterventional Surgery · doi:10.1136/neurintsurg-2022-018912 · Cited by 4
“In an international aneurysm segmentation challenge, participating teams consistently over-estimated neck width in one case; only one team accurately recovered the neck through empirical inspection and manual editing of the segmented model, involving a reported editing time of 26 hours [3].”
BackgroundMethodInfluentialAmplification of Secondary Flow at the Initiation Site of Intracranial Sidewall Aneurysms
Csippa, B., Friedrich, P., Szikora, I., & Paál, G. (2025) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-025-00771-4 · Cited by 2
“Medical image segmentation and subsequent smoothing of the resulting vessel surface are operator-dependent and highly subjective, leading to improper geometry representations [20, 21], which might partly explain the confounding result existing in the literature.”
Luglietto, D., BENEDICTIS, A. D., Marasi, A., Rossi‐Espagnet, M. C., Napolitano, A., Capelli, S., Ricciuti, V., Riccio, D., & Marras, C. E. (2025) · Life · doi:10.3390/life15050777 · Cited by 2
“Moreover, for intracranial aneurysms, the MATCH study research groups defined the most popular segmentation algorithms for intracranial aneurysms in 3D DSAs datasets [27].”
Kjeldsberg, H. A., Bergersen, A. W., & Valen‐Sendstad, K. (2021) · BioMedical Engineering OnLine · doi:10.1186/s12938-021-00957-6 · Cited by 3
“Thus, the variability in segmentation may potentially be exaggerated, although these surface models were qualitatively similar to other studies [17].”
ResultNozaleda, G. L., Poloni, S., Soliveri, L., & Valen‐Sendstad, K. (2024) · Simula SpringerBriefs on computing · doi:10.1007/978-3-031-53145-3_7 · Cited by 2
Boundary Condition Options for Carotid Bifurcation Analysis, Using Doppler Velocity Measurements
Németh, M. B., Csippa, B., Mihály, Z., Paál, G., & Sótonyi, P. (2024) · Periodica Polytechnica Mechanical Engineering · doi:10.3311/ppme.28797 · Cited by 1
“These uncertainties, that result from the subjectivity of user choices in the model, generally appear as over-segmentation [10, 11], which results larger arterial diameters.”
BackgroundCsippa, B., Sándor, L., & Paál, G. (2021) · Periodica Polytechnica Mechanical Engineering · doi:10.3311/ppme.18517 · Cited by 2
Computational Physiology: Simula Summer School 2023 − Student Reports
McCabe, K. J. (2024) · Simula SpringerBriefs on computing · doi:10.1007/978-3-031-53145-3 · Cited by 2
Exploring the Variations in Angles Around Basilar Bifurcation Categorized by Aneurysm Locations
Pan, F., Bijlenga, P., Mori, N., Mugikura, S., Ohta, M., & Anzai, H. (2023) · Biomedical Engineering International Conference · doi:10.1109/bmeicon60347.2023.10322063 · Cited by 1
“The 3D geometries reconstructed from medical images exhibited variability depending on the operators [24].”
BackgroundPredicting Cerebral Aneurysm Rupture
Goudarzian, F., Kondratiuk, K., & Rayz, V. L. (2025) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2025.05.002 · Cited by 1
Vascular Blood Flow Imaging: Pushing Boundaries, Shaping the Future
Ruisch, J., van de Velde, L., de Korte, C. L., Holewijn, S., Jebbink, E. G., Versluis, M., Saris, A. E. C. M., & Reijnen, M. M. P. J. (2025) · IEEE International Ultrasonics Symposium · doi:10.1109/ius62464.2025.11201613 · Cited by 2
“A study on intracranial aneurysms involving 26 teams showed up to 20% variation in segmented volumes [30], leading to 28-51% inter-group differences in time-averaged WSS [31].”
Hemodynamics in Ruptured Intracranial Aneurysms
Hejčl, A., Mária, S., Švihlová, H., Sejkorová, A., Radovnický, T., Hron, J., Feletti, A., Koblížek, M., Zámečník, J., Vladimír, B., et al. (2019) · IntechOpen eBooks · doi:10.5772/intechopen.88695 · Cited by 1
“The vast differences among the research groups confirmed the fact that various algorithms may lead to significant differences in the hemodynamic analysis [52].”
BackgroundKrisztina, T. B., Huba, M., & Lakatos, É. I. (1970) · Biomechanica Hungarica · doi:10.17489/biohun/2023/1/585
Input Parameterized Physics Informed Neural Network for Advanced 4d Flow MRI ProcessingPreprint
Kalajahi, A. P., Csala, H., Naderi, F., Mamun, Z. B., Yadav, S., Amili, O., Arzani, A., & D'Souza, R. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4700974 · Cited by 2
Can the Flow Simulation Domain for Bifurcation Aneurysms on the Willis Circle Be Radically Reduced?
Friedrich, P., & Paál, G. (2024) · Periodica Polytechnica Mechanical Engineering · doi:10.3311/ppme.37086
“As wall-based methods highly depend on the exact surface geometry of the wall, they carry uncertainties, due to the subjective elements of the segmentation process [14, 15].”
MethodHemodynamic Modelling and Simulation of Flow Diverters for Intracranial Aneurysm Treatment
Rico, P. J. (2024) · theses.fr (ABES) · doi:10.70675/82159e05z3ff8z41a2zbe6az1839913f6940
Coupet, M., Meftah, M., Lopez, C., Maintier, L., Guezou‐Philippe, A., Ognard, J., Gentric, J., Burdin, V., Magro, E., & Dardenne, G. (2026) · PLoS ONE · doi:10.1371/journal.pone.0358945
“More recently, various challenges such as the 2018 Multiple AneurysmsAn-aTomyCHallenge (MATCH) [12], the 2020 Aneurysm Detection and SegMentation (ADAM) [13], or the 2020 Aneurysm Detection and Analysis (CADA) [14] challenges have been organized to provide data and compare the performance of the…”
Metadata
- Authors
- Berg, P., Voß, S., Saalfeld, S., Janiga, G., Bergersen, A. W., Valen-Sendstad, K., Bruening, J., Goubergrits, L., Spuler, A., Cancelliere, N. M., Steinman, D. A., Pereira, V. M., Chiu, T. L., Tsang, A. C. O., Chung, B. J., Cebral, J. R., Cito, S., Pallarès, J., Copelli, G., Csippa, B., Paál, G., Fujimura, S., Takao, H., Hodis, S., Hille, G., Karmonik, C., Elias, S., Kellermann, K., Khan, M. O., Marsden, A. L., Morales, H. G., Piskin, S., Finol, E. A., Pravdivtseva, M., Rajabzadeh-Oghaz, H., Paliwal, N., Meng, H., Seshadhri, S., Howard, M., Shojima, M., Sugiyama, S.-I., Niizuma, K., Sindeev, S., Frolov, S., Wagner, T., Brawanski, A., Qian, Y., Wu, Y.-A., Carlson, K. D., Dragomir-Daescu, D., & Beuing, O.
- Affiliations
- Otto-von-Guericke-Universität Magdeburg (DE)
- Simula Research Laboratory (NO)
- Charité – Universitätsmedizin Berlin (DE)
- Helios Hospital Berlin-Buch (DE)
- University Health Network (CA)
- University of Toronto (CA)
- University of Hong Kong (HK)
- George Mason University (US)
- Universitat Rovira i Virgili (ES)
- University of Parma (IT)
- Budapest University of Technology and Economics (HU)
- Jikei University School of Medicine (JP)
- Texas A&M University – Kingsville (US)
- Houston Methodist (US)
- Stanford University (US)
- Universidad Mayor (CL)
- The University of Texas at San Antonio (US)
- University Hospital Schleswig-Holstein (DE)
- University at Buffalo, State University of New York (US)
- Medtronic (India) (IN)
- Synopsys (United States) (US)
- Saitama Medical University (JP)
- Tohoku University (JP)
- OTH Regensburg (DE)
- University Hospital Regensburg (DE)
- Macquarie University (AU)
- Mayo Clinic (US)
- University Hospital Magdeburg (DE)
- Corresponding author
- Berg, Philipp
- ORCID
- Berg, Philipp
- Voß, Samuel
- Saalfeld, Sylvia
- Janiga, Gábor
- Bergersen, Aslak W.
- Goubergrits, Leonid
- Spuler, Andreas
- Cancelliere, Nicole M.
- Steinman, David A.
- Chiu, Tin Lok
- Tsang, Anderson Chun On
- Chung, Bong Jae
- Cebral, Juan R.
- Cito, Salvatore
- Pallarès, Jordi
- Paál, György
- Fujimura, Soichiro
- Takao, Hiroyuki
- Hodis, Simona
- Karmonik, Christof
- Elias, Saba
- Khan, Muhammad Owais
- Marsden, Alison L.
- Morales, Hernán G.
- Finol, Ender A.
- Pravdivtseva, Mariya
- Rajabzadeh-Oghaz, Hamidreza
- Paliwal, Nikhil
- Meng, Hui
- Shojima, Masaaki
- Sugiyama, Shin-ichiro
- Niizuma, Kuniyasu
- Brawanski, Alexander
- Qian, Yi
- Beuing, Oliver
- Venue
- Cardiovascular Engineering and Technology
- Published
- 2018-09-06
- Volume
- 9
- Issue
- 4
- Pages
- 565-581
- ISSN
- 1869-408X (ISSN-L)
- 1869-4098
- OpenAlex
- W2891940995
- Cited by
- 79
- References
- 49
- Citations by year
- 2026: 1 · 2025: 8 · 2024: 16 · 2023: 8 · 2022: 11 · 2021: 11 · 2020: 9 · 2019: 13 · 2018: 1
- FWCI
- 5.77
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.springer.com/tdm (tdm)
- Locations
- Cardiovascular Engineering and Technology (publishedVersion)
- PubMed (publishedVersion)
- Rovira & Virgili repository (submittedVersion, cc-by)
- University of Regensburg Publication Server (University of Regensburg) (submittedVersion)
- Institutional Repositories DataBase (IRDB) (submittedVersion, cc-by-nc-nd)
- Funders
- Bundesministerium für Bildung und Forschung (13GW0095A)
- Deutsche Forschungsgemeinschaft (399581926)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Intracranial Aneurysms: Treatment and Complications
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cerebrovascular and Carotid Artery Diseases
- Keywords
- intracranial aneurysm, vessel wall segmentation, segmentation benchmark, aneurysm morphology, aneurysm volume, surface reconstruction, aneurysm rupture risk, 3D digital subtraction angiography, aneurysm neck
- MeSH terms
- Blood Flow Velocity, Intracranial Aneurysm, Cerebral Angiography, Cerebrovascular Circulation, Female, Hemodynamics, Humans, Middle Aged, Models, Cardiovascular, Predictive Value of Tests, Prognosis, Radiographic Image Interpretation, Computer-Assisted, Regional Blood Flow, Risk Factors, Stress, Mechanical, Subarachnoid Hemorrhage, Reproducibility of Results, Aneurysm, Ruptured, Risk Assessment, Middle Cerebral Artery, Imaging, Three-Dimensional, Patient-Specific Modeling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.