CoChat

Improving Proteome Coverage on a LTQ-Orbitrap Using Design of Experiments

Open access
Andrews, Genna L., Dean, Ralph A., Hawkridge, Adam M., Muddiman, David C. · 2011 · Journal of the American Society for Mass Spectrometry
Cited by 63

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Design of experiments (DOE) was used to determine improved settings for a LTQ-Orbitrap XL to maximize proteome coverage of Saccharomyces cerevisiae. A total of nine instrument parameters were evaluated with the best values affording an increase of approximately 60% in proteome coverage. Utilizing JMP software, 2 DOE screening design tables were generated and used to specify parameter values for instrument methods. DOE 1, a fractional factorial design, required 32 methods fully resolving the investigation of six instrument parameters involving only half the time necessary for a full factorial design of the same resolution. It was advantageous to complete a full factorial design for the analysis of three additional instrument parameters. Measured with a maximum of 1% false discovery rate, protein groups, unique peptides, and spectral counts gauged instrument performance. Randomized triplicate nanoLC-LTQ-Orbitrap XL MS/MS analysis of the S. cerevisiae digest demonstrated that the following five parameters significantly influenced proteome coverage of the sample: (1) maximum ion trap ionization time; (2) monoisotopic precursor selection; (3) number of MS/MS events; (4) capillary temperature; and (5) tube lens voltage. Minimal influence on the proteome coverage was observed for the remaining four parameters (dynamic exclusion duration, resolving power, minimum count threshold to trigger a MS/MS event, and normalized collision energy). The DOE approach represents a time- and cost-effective method for empirically optimizing MS-based proteomics workflows including sample preparation, LC conditions, and multiple instrument platforms.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s13361-011-0075-2

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 63

Metadata

Authors
Andrews, G. L., Dean, R. A., Hawkridge, A. M., & Muddiman, D. C.
Venue
Journal of the American Society for Mass Spectrometry
Published
2011-02-15
Volume
22
Issue
4
Pages
773-783
ISSN
1044-0305 (ISSN-L)
OpenAlex
W2094835462
Cited by
63
References
6
FWCI
2.87
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improving Proteome Coverage on a LTQ-Orbitrap Using Design of Experiments. https://app.cochat.ai/papers/10.1007/s13361-011-0075-2
The paper
Andrews, G. L., Dean, R. A., Hawkridge, A. M., & Muddiman, D. C. (2011). Improving Proteome Coverage on a LTQ-Orbitrap Using Design of Experiments. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1007/s13361-011-0075-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.