CoChat

Controlled Ion Ejection from an External Trap for Extended m/z Range in FT-ICR Mass Spectrometry

Kaiser, Nathan K., Savory, Joshua J., Hendrickson, Christopher L. · 2014 · Journal of the American Society for Mass Spectrometry
Cited by 46

The DOI matches its Crossref record.

Abstract

An auxiliary rf waveform of the same amplitude and phase applied to all the rods of an ion accumulation multipole creates an m/z-dependent axial pseudo potential. Controlled decrease of the auxiliary rf amplitude releases ions from the accumulation multipole sequentially from high to low m/z. The slope of the auxiliary rf voltage ramp is adjusted so that ions of different m/z reach the center of the ICR cell at the same time point, which mitigates the typical time dispersion observed in external source FT-ICR and extends the observable mass range for a single data acquisition by 2- to 3-fold. For complex mixture analysis, twice the number of elemental compositions are assigned when the auxiliary rf ejection is applied compared with the standard gated trapping.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s13361-014-0871-6

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 46

Metadata

Authors
Kaiser, N. K., Savory, J. J., & Hendrickson, C. L.
Venue
Journal of the American Society for Mass Spectrometry
Published
2014-04-02
Volume
25
Issue
6
Pages
943-949
ISSN
1044-0305 (ISSN-L)
OpenAlex
W2051574219
Cited by
46
References
0
FWCI
1.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Controlled Ion Ejection from an External Trap for Extended m/z Range in FT-ICR Mass Spectrometry. https://app.cochat.ai/papers/10.1007/s13361-014-0871-6
The paper
Kaiser, N. K., Savory, J. J., & Hendrickson, C. L. (2014). Controlled Ion Ejection from an External Trap for Extended m/z Range in FT-ICR Mass Spectrometry. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1007/s13361-014-0871-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.