Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 24Balance, Gait, and Falls PreventionCognitive Functions and MemoryNeural and Behavioral Psychology Studies

The DOI matches its Crossref record; 26 of the 27 references it cites were found in a registry or an index; none of the 11 sources its claims cite is checked for support yet.

Validity and reliability of a ruler drop test to measure dual-task reaction time, choice reaction time and discrimination reaction time

Open access
Ferreira, Soraia, Raimundo, Armando, del Pozo-Cruz, Jesus, Leite, Nilton, Pinto, Ana, Marmeleira, José·2024·Aging Clinical and Experimental Research

Abstract

Background: The aim of this study was to determine the absolute and relative reliability of the Ruler Drop Test (RDT) for assessing dual-task, choice, and discrimination reaction time. In addition, the construct validity of the RDT is examined in comparison to the Deary-Liewald reaction time (DLRT). Methods: Tests were administered by the same evaluator, one week apart. Intraclass Correlation Coefficient (ICC3.1) was used to measure relative reliability, and the standard error of measurement (SEM) and minimal detectable change (MDC95) were used to measure absolute reliability. Spearman correlation test was used to measure construct validity. Results: The results showed that the relative reliability was good for the choice ruler drop (ICC = 0.81), moderate for the dual-task ruler drop test (ICC = 0.70) and discrimination ruler drop test (ICC = 0.72), and good for simple ruler drop test. However, the simple ruler drop test had poor reliability (ICC = 0.57). The RDT shows construct validity compared to the DLRT. Conclusion: We conclude that the RDT is a suitable instrument for measuring dual-task, choice and discrimination reaction time. Future studies should explore the reliability of these measures in other populations.

Overview

CoChat Summary

TL;DR

The ruler drop test adapted for choice, dual-task, and discrimination reaction time showed moderate-to-good relative reliability in community-dwelling older adults, with construct validity against the Deary-Liewald reaction time task. Simple ruler drop test reliability was lower (ICC = 0.57), and some error-count measures showed poor reliability.

Key findings

  • In 51 older adults (mean age 72.67 ± 5.3 years), test-retest ICCs were 0.81 for RDT-C, 0.70 for RDT-DT, 0.72 for RDT-D, and 0.57 for RDT-S; RDT-C non-dominant-hand errors (ICC = 0.48) and RDT-D errors (ICC = 0.45) had poor reliability.
  • Absolute reliability values were SEM = 12.5% for RDT-S, 10% for RDT-C, 12.4% for RDT-DT, and 17.1% for RDT-D; MDC95 values were 34.5%, 27.6%, 34.3%, and 47.2%, respectively.
  • Construct validity was supported by significant Spearman correlations between RDT and DLRT measures: RDT-S vs DLRT-S (r = 0.423, p = 0.002), RDT-C vs DLRT-C (r = 0.394, p < 0.01), RDT-DT vs DLRT-SDT (r = 0.322, p < 0.01), and RDT-D vs DLRT-SDT and DLRT-C (r = 0.375, p < 0.01).

Methods

  • Cross-sectional test-retest reliability and validity study with 51 community-dwelling volunteers in Évora, Portugal, aged ≥60 years without cognitive impairment; exclusions were low vision, cognitive impairment, or Parkinson’s disease.
  • RDT-S, RDT-DT, RDT-C, RDT-D, and DLRT variants were administered twice, one week apart, by the same experienced kinesiologist after familiarization.
  • Relative reliability was assessed with ICC3.1, absolute reliability with SEM and MDC95, and construct validity with Spearman correlation; the required sample size was calculated as 46, and analyses used SPSS 24.0 with p < 0.05.

Limitations

  • The paper states that individuals with low peripheral vision could not perform the choice reaction time test, that results may not generalize to nursing home residents, and that different ruler materials might alter reaction time results.
  • Evident from the text: several error-count measures had poor reliability (RDT-C non-dominant-hand errors ICC = 0.48; RDT-D errors ICC = 0.45), and RDT-C SEM exceeded the SEM < SD/2 criterion, indicating unacceptable measurement accuracy for that test.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1007/s40520-024-02726-6

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Fig. 1 Ruler drop test, simple testing procedure
Fig. 1 Ruler drop test, simple testing procedureCC BY · PubMed Central
Fig. 2 Choice Ruler drop test procedure
Fig. 2 Choice Ruler drop test procedureCC BY · PubMed Central

Verification

Claims the paper makes

0 Valid · 0 Not valid · 11 Not checked · 68 Own results and interpretations

39 more claims

Create a free account to see all 79 claims and to verify the 10 references still open.

See all claims — free account
  • Probably not a substantial claim. 25
  • It may state two separate claims as one. 19
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

5 of 10 · the rest aren’t loaded

5 more findings

Create a free account to see every finding of this check.

See all findings — free account

Citations

Cites

Research works printed but not linked: 6

  1. Johnson BL, Nelson JK (1969) Practical measurements for evaluation in physical education. Fourth edi. Burgess Pub. Co, New York., p 477
  2. Cox B, Huppert F, Whichelow M (1993) The health and lifestyle survey: seven years on. UK: Dartmouth, Aldershot
  3. Jensen A (1987) Individual differences in the Hick paradigm. In: Vernon PA (ed) Speed of information-processing and intelligence. Ablex Publishing, pp. 101–175
  4. Schuhfried (2013) Vienna Test System: Psychological Assessment. Schuhfried, Moedling, Austria
  5. Guerreiro M, Silva A, Botelho M, Leitão O, Castro-Caldas A, Garcia C (1994) Adaptação à população Portuguesa Da tradução do Mini Mental State Examination (MMSE) – ScienceOpen. Rev Port Neurol 3(suppl):9–10
  6. Johnson BL, Nelson JK (1986) Practical measurements for evaluation in Physical Education. Fourth edi. Macmillan, New York

Cited by

See all 24

Metadata

Authors
Ferreira, S., Raimundo, A., del Pozo-Cruz, J., Leite, N., Pinto, A., & Marmeleira, J.
Affiliations
University of Évora (PT)
Corresponding author
Ferreira, Soraia
Venue
Aging Clinical and Experimental Research
Published
2024-03-07
Volume
36
Issue
1
Pages
61-61
ISSN
  • 1594-0667 (ISSN-L)
  • 1720-8319
OpenAlex
W4392559705
Cited by
23
References
27
Citations by year
2026: 17 · 2025: 2 · 2024: 4
FWCI
10.83
Type
journal article
Language
en
Open access
Licence
Locations
  • Aging Clinical and Experimental Research (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) (submittedVersion, other-oa)
Funders
Universidade de Évora
Topics
  • Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Cognitive Functions and Memory
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Neural and Behavioral Psychology Studies
Keywords
ruler drop test, reaction time, dual-task performance, choice reaction time, test-retest reliability, construct validity, cognitive aging, neuropsychological assessment
MeSH terms
Humans, Reaction Time, Reproducibility of Results

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-14, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-14 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.