Frequency Control Ancillary Service Provided by a Wind Farm: Dual-BESS Scheme
Open accessAbstract
Network frequency control function is incorporated into a grid-connected wind farm-dual battery energy storage system (BESS) scheme. The design of the scheme takes advantage of the rapid response characteristics of the BESS and the in-built short-term overloading capability of the associated power conversion devices. A control strategy to regulate the BESS output power is then proposed. It is shown that the frequency control action offered by the BESS complements amicably with that of conventional generators in enhancing the frequency regulation attribute of the grid system.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Inverters have low thermal inertia, which imposes restrictions on their overload capability in all operating modes, usually up to 1.3-1.5 of rated current.
“Inverters have low thermal inertia, which imposes restrictions on their overload capability in all operating modes, usually up to 1.3-1.5 of rated current [34,35].”
From Determining Volt/Var Characteristics of Electric Vehicle Charging Station Inverters for Voltage Regulation in Distribution Networks (2024) · cites this paper as [34]
Section 3.1 (page not specified) says inverter overload capability is limited and varies with overload duration; Section 3.2 likewise says it is valid only for a limited duration. The paper does not attribute those limits to low thermal inertia or give a usual limit of 1.3–1.5 times rated current across all operating modes. (LLM, conf=0.85)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
No references could be resolved yet.
Research works printed but not linked: 22
- Rebours YG, Kirschen DS, Trotignon M et al (2007) A survey of frequency and voltage control ancillary services-Part II: eco- nomic features. IEEE Trans Power Syst 22(1):358-366
- Rebours YG, Kirschen DS, Trotignon M et al (2007) A survey of frequency and voltage control ancillary services-Part I: Tech- nical features. IEEE Trans Power Syst 22(1):350-357
- Yao DL, Choi SS, Tseng KJ et al (2012) Determination of short- term power dispatch schedule for a wind farm incorporated with dual-battery energy storage scheme. IEEE Trans Sustain Energy 3(1):74-84
- Yao DL, Choi SS, Tseng KJ et al (2010) Determination of a dispatch strategy to maximize income for a wind turbine-BESS Fig. 8 (a) System frequency deviation without the BESS. (b) Ther- mal generation output without the BESS 102 Dailin YAO et al. power station. In: Proceedings of the international power and energy conference (IPEC'10), Singapore, 27-29 Oct 2010, 6p
- Yao DL, Choi SS, Tseng KJ et al (2012) Dynamic study of a battery change-over scheme of a wind farm containing dual BESS. In: Proceedings of the international power and energy conference (IPEC'12), Ho Chi Minh City, Vietnam, 12-14 Dec 2012, 7p
- Aditya SK, Das D (2001) Battery energy storage for load fre- quency control of an interconnected power system. Electr Power Syst Res 58(3):179-185
- Lu CF, Liu CC, Wu CJ (1995) Effect of battery energy storage system on load frequency control considering governor dead- band and generation rate constraint. IEEE Trans Energy Conver 10(3):555-561
- Mercier P, Cherkaoui R, Oudalov A (2009) Optimizing a battery energy storage system for frequency control application in an isolated power system. IEEE Trans Power Syst 24(3):1469-1477
- Oudalov A, Chartouni D, Ohler C (2007) Optimizing a battery energy storage system for primary frequency control. IEEE Trans Power Syst 22(3):1259-1266
- Sekyung H, Soohee H, Sezaki K (2010) Development of an optimal vehicle-to-grid aggregator for frequency regulation. IEEE Trans Smart Grid 1(1):65-72
- Goya T, Omine E, Kinjyo Y et al (2011) Frequency control in isolated island by using parallel operated battery systems applying H? control theory based on droop characteristics. IET Renew Power Gener 5(2):160-166
- Oudalov A, Chartouni D, Ohler C et al (2006) Value analysis of battery energy storage applications in power systems. In: Pro- ceedings of the 2006 IEEE PES power systems conference and exposition (PSCE'06), Atlanta, GA, USA, 2206-2211 29 Oct-1 Nov 2006
- Z ˇertek A, Verbic ˇG, Pantos ˇM (2012) Optimised control approach for frequency-control contribution of variable speed wind turbines. IET Renew Power Gener 6(1):17-23
- Teninge A, Jecu C, Roye D et al (2009) Contribution to fre- quency control through wind turbine inertial energy storage. IET Renew Power Gener 3(3):358-370
- Zhang ZS, Sun YZ, Lin J et al (2012) Coordinated frequency regulation by doubly fed induction generator-based wind power plants. IET Renew Power Gener 6(1):38-47
- Keung PK, Li P, Banakar H et al (2009) Kinetic energy of wind- turbine generators for system frequency support. IEEE Trans Power Syst 24(1):279-287
- Ma HT, Chowdhury BT (2010) Working towards frequency regulation with wind plants: combined control approaches. IET Renew Power Gener 4(4):308-316
- Bevrani H, Hiyama T (2011) Intelligent automatic generation control. CRC Press, Boca Raton, FL, USA
- Nichols DK, Eckroad S (2003) Utility-scale application of sodium sulfur battery. In: Proceedings of the 7th annual inter- national stationary battery conference (Battcon'03), Marco Island, FL, USA, 28-30 Apr 2003, 9p
- Sugawara Y, Ogata S, Izumi T et al (2009) Development of a 100 kVA SiC inverter with high overload capability of 300 kVA. In: Proceedings of the international symposium on power semiconductor devices and IC's (ISPSD'09), Barcelona, Spain, 14-18 Jun 2009, 4p
- Saadat H (2004) Power system analysis. McGraw-Hill, Singapore
- King JET TSENG was born in Singapore. He received the B.Eng. (First Class) and M.Eng. degrees from the National University of Singapore, Singapore, and the Ph.D. degree from Cambridge University, Cambridge, U.K. He is currently the Head of Power Engineering Division at the School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore. He teaches electrical power engineering and power electronics at both undergraduate and postgraduate levels, and manages a number of research programs in the area of electrical energy and power.
Cited by
Sorted by citations
Voronin, V., Nepsha, F., & Ilyushin, P. (2024) · World Electric Vehicle Journal · doi:10.3390/wevj15120553 · Cited by 3 · see citing works
“Inverters have low thermal inertia, which imposes restrictions on their overload capability in all operating modes, usually up to 1.3–1.5 of rated current [34,35].”
Influential
- Authors
- YAO, D., CHOI, S. S., TSENG, K. J., & LIE, T. T.
- Affiliations
- Nanyang Technological University (SG)
- Auckland University of Technology (NZ)
- Venue
- Journal of Modern Power Systems and Clean Energy
- Published
- 2014-05-05
- Volume
- 2
- Issue
- 2
- Pages
- 93-103
- ISSN
- 2196-5420 (ISSN-L)
- 2196-5625
- OpenAlex
- W2078464171
- Cited by
- 6
- References
- 0
- Citations by year
- 2024: 1 · 2022: 1 · 2017: 4
- FWCI
- 0.85
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Locations
- Journal of Modern Power Systems and Clean Energy (publishedVersion, cc-by)
- QUT ePrints (Queensland University of Technology) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- DR-NTU (Nanyang Technological University) (submittedVersion, cc-by)
- eSpace (Curtin University) (submittedVersion)
- Topics
- Physical Sciences › Energy › Energy Engineering and Power Technology › Power Systems and Renewable Energy
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Frequency Control in Power Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wind Turbine Control Systems
- Keywords
- frequency regulation, ancillary services, wind farms, battery energy storage, grid-connected wind power, power converters
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review