Silver Nanowire Electrodes: Conductivity Improvement Without Post-treatment and Application in Capacitive Pressure Sensors
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Transparent electrode based on silver nanowires (AgNWs) emerges as an outstanding alternative of indium tin oxide film especially for flexible electronics. However, the conductivity of AgNWs transparent electrode is still dramatically limited by the contact resistance between nanowires at high transmittance. Polyvinylpyrrolidone (PVP) layer adsorbed on the nanowire surface acts as an electrically insulating barrier at wire–wire junctions, and some devastating post-treatment methods are proposed to reduce or eliminate PVP layer, which usually limit the application of the substrates susceptible to heat or pressure and burden the fabrication with high-cost, time-consuming, or inefficient processes. In this work, a simple and rapid pre-treatment washing method was proposed to reduce the thickness of PVP layer from 13.19 to 0.96 nm and improve the contact between wires. AgNW electrodes with sheet resistances of 15.6 and 204 Ω sq −1 have been achieved at transmittances of 90 and 97.5 %, respectively. This method avoided any post-treatments and popularized the application of high-performance AgNW transparent electrode on more substrates. The improved AgNWs were successfully employed in a capacitive pressure sensor with high transparency, sensitivity, and reproducibility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hu, W., Niu, X., Zhao, R., & Pei, Q. (2013) · Applied Physics Letters · doi:10.1063/1.4794143 · Cited by 332 · cited 1×
“Transparent electrodes are regarded as essential components in optoelectronic applications such as solar cells, touch screens, organic light-emitting diodes, and sensor devices [1–4], and indium tin oxide (ITO) thin films are the most widely used material for such applications.”
Background
Cited by
Metal–Organic Framework-Based Sensors for Environmental Contaminant Sensing
Fang, X., Zong, B., & Mao, S. (2018) · Nano-Micro Letters · doi:10.1007/s40820-018-0218-0 · Cited by 576
Transparent Electronics for Wearable Electronics Application
Won, D., Bang, J., Choi, S. H., Pyun, K. R., Jeong, S., Lee, Y., & Ko, S. H. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00139 · Cited by 339
Azani, M., Hassanpour, A., & Torres, T. (2020) · Advanced Energy Materials · doi:10.1002/aenm.202002536 · Cited by 326
Wang, J., Jiu, J., Nogi, M., Sugahara, T., Nagao, S., Koga, H., He, P., & Suganuma, K. (2015) · Nanoscale · doi:10.1039/c4nr06494a · Cited by 293
Self-citationFlexible capacitive pressure sensors for wearable electronics
Wang, H., Li, Z., Liu, Z., Fu, J., Shan, T., Yang, X., Lei, Q., Yang, Y., & Li, D. (2022) · Journal of Materials Chemistry C · doi:10.1039/d1tc05304c · Cited by 263
Metadata
- Authors
- Wang, J., Jiu, J., Araki, T., Nogi, M., Sugahara, T., Nagao, S., Koga, H., He, P., & Suganuma, K.
- Venue
- Nano-Micro Letters
- Published
- 2014-11-14
- Volume
- 7
- Issue
- 1
- Pages
- 51-58
- ISSN
- 2150-5551 (ISSN-L)
- 2311-6706
- OpenAlex
- W2006009713
- Cited by
- 143
- References
- 1
- FWCI
- 5.66
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.