The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Single-Atom Cobalt-Based Electrochemical Biomimetic Uric Acid Sensor with Wide Linear Range and Ultralow Detection Limit
Open accessAbstract
Uric acid (UA) detection is essential in diagnosis of arthritis, preeclampsia, renal disorder, and cardiovascular diseases, but it is very challenging to realize the required wide detection range and low detection limit. We present here a single-atom catalyst consisting of Co(II) atoms coordinated by an average of 3.4 N atoms on an N-doped graphene matrix (A–Co–NG) to build an electrochemical biomimetic sensor for UA detection. The A–Co–NG sensor achieves a wide detection range over 0.4–41,950 μM and an extremely low detection limit of 33.3 ± 0.024 nM, which are much better than previously reported sensors based on various nanostructured materials. Besides, the A–Co–NG sensor also demonstrates its accurate serum diagnosis for UA for its practical application. Combination of experimental and theoretical calculation discovers that the catalytic process of the A–Co–NG toward UA starts from the oxidation of Co species to form a Co 3+–OH–UA*, followed by the generation of Co 3+–OH + *UA_H, eventually leading to N–H bond dissociation for the formation of oxidized UA molecule and reduction of oxidized Co 3+ to Co 2+ for the regenerated A–Co–NG. This work provides a promising material to realize UA detection with wide detection range and low detection limit to meet the practical diagnosis requirements, and the proposed sensing mechanism sheds light on fundamental insights for guiding exploration of other biosensing processes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Single-atom catalysis of CO oxidation using Pt1/FeOx
Qiao, B., Wang, A., Yang, X., Allard, L. F., Jiang, Z., Cui, Y., Liu, J., Li, J., & Zhang, T. (2011) · Nature Chemistry · doi:10.1038/nchem.1095 · Cited by 7,526
Atomically dispersed Ni(i) as the active site for electrochemical CO2 reduction
Yang, H. B., Hung, S.-F., Liu, S., Yuan, K., Miao, S., Zhang, L., Huang, X., Wang, H.-Y., Cai, W., Chen, R., et al. (2018) · Nature Energy · doi:10.1038/s41560-017-0078-8 · Cited by 2,239
Self-citationFei, H., Dong, J., Feng, Y., Allen, C. S., Wan, C., Volosskiy, B., Li, M., Zhao, Z., Wang, Y., Sun, H., et al. (2018) · Nature Catalysis · doi:10.1038/s41929-017-0008-y · Cited by 1,973
Self-citation
Cited by
Feng, D., Cao, F., Hou, L., Li, T., Jiao, Y., & Wu, P. (2021) · Small · doi:10.1002/smll.202103195 · Cited by 418
Metadata
- Authors
- Hu, F. X., Hu, T., Chen, S., Wang, D., Rao, Q., Liu, Y., Dai, F., Guo, C., Yang, H. B., & Li, C. M.
- Venue
- Nano-Micro Letters
- Published
- 2020-10-27
- Volume
- 13
- Issue
- 1
- Pages
- 7-7
- ISSN
- 2150-5551 (ISSN-L)
- 2311-6706
- OpenAlex
- W3096424354
- Cited by
- 172
- References
- 3
- FWCI
- 6.67
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.