Electromyography-Based Quantitative Representation Method for Upper-Limb Elbow Joint Angle in Sagittal Plane
Open accessAbstract
This paper presents a quantitative representation method for the upper-limb elbow joint angle using only electromyography (EMG) signals for continuous elbow joint voluntary flexion and extension in the sagittal plane. The dynamics relation between the musculotendon force exerted by the biceps brachii muscle and the elbow joint angle is developed for a modified musculoskeletal model. Based on the dynamics model, a quadratic-like quantitative relationship between EMG signals and the elbow joint angle is built using a Hill-type-based muscular model. Furthermore, a state switching model is designed to stabilize the transition of EMG signals between different muscle contraction motions during the whole movement. To evaluate the efficiency of the method, ten subjects performed continuous experiments during a 4-day period and five of them performed a subsequent consecutive stepping test. The results were calculated in real-time and used as control reference to drive an exoskeleton device bilaterally. The experimental results indicate that the proposed method can provide suitable prediction results with root-mean-square (RMS) errors of below 10° in continuous motion and RMS errors of below 10° in stepping motion with 20° and 30° increments. It is also easier to calibrate and implement.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Alternative strategies for high-resolution analysis of an infant's motor development involve quantitative data from digital imaging systems or commercial wearable sensors packages, often also with electroencephalography or electromyography.
“Alternative strategies for high-resolution analysis of an infant’s motor development involve quantitative data from digital imaging systems or commercial wearable sensors packages (11–15), often also with electroencephalography (16) or electromyography (17).”
From Miniaturized wireless, skin-integrated sensor networks for quantifying full-body movement behaviors and vital signs in infants (2021) · cites this paper as [17]
The Abstract describes a quantitative EMG method for estimating elbow movement, supporting the citation as an example of electromyography-based motor analysis. The Experimental Setup reports ten healthy volunteers with a mean age of 24.60 years; the paper does not study infant motor development or establish that EMG is often used for its analysis. No page numbers are available in our copy. (LLM, conf=0.86)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
The heat of shortening and the dynamic constants of muscle
Hill, A. V. (1938) · Proceedings of the Royal Society B Biological Sciences · doi:10.1098/rspb.1938.0050 · Cited by 5,570 · see citing works
Muscle Structure and Theories of Contraction
Huxley, A. F. (1957) · Progress in Biophysics and Biophysical Chemistry · doi:10.1016/s0096-4174(18)30128-8 · Cited by 3,437 · see citing works
The Use of Surface Electromyography in Biomechanics
Luca, C. J. D. (1997) · Journal of Applied Biomechanics · doi:10.1123/jab.13.2.135 · Cited by 3,293 · see citing works
Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control.
Zajac, F. E. (1989) · PubMed · Cited by 2,980 · see citing works
Proposed Mechanism of Force Generation in Striated Muscle
Huxley, A. F., & Simmons, R. M. (1971) · Nature · doi:10.1038/233533a0 · Cited by 2,276 · see citing works
Techniques of EMG signal analysis: detection, processing, classification and applications
Reaz, M. B. I., Hussain, M. S., & Mohd-Yasin, F. (2006) · Biological Procedures Online · doi:10.1251/bpo115 · Cited by 1,636 · see citing works
Buchanan, T. S., Lloyd, D. G., MANAL, K. T., et al. (2004) · Journal of Applied Biomechanics · doi:10.1123/jab.20.4.367 · Cited by 946 · see citing works
A human-assisting manipulator teleoperated by EMG signals and arm motions
Fukuda, O., Tsuji, T., Kaneko, M., & Otsuka, A. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.808873 · Cited by 483 · see citing works
The heat of activation and the heat of shortening in a muscle twitch
Hill, A. V. (1949) · Proceedings of the Royal Society B Biological Sciences · doi:10.1098/rspb.1949.0019 · Cited by 419 · see citing works
A Human--Exoskeleton Interface Utilizing Electromyography
Fleischer, C., & Hommel, G. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.926860 · Cited by 415 · see citing works
Tele-impedance: Teleoperation with impedance regulation using a body–machine interface
Ajoudani, A., Tsagarakis, N. G., & Bicchi, A. (2012) · The International Journal of Robotics Research · doi:10.1177/0278364912464668 · Cited by 277 · see citing works
Learning EMG control of a robotic hand: towards active prostheses
Bitzer, S., & van der Smagt, P. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2006.1642128 · Cited by 247 · see citing works
Multijoint Muscle Regulation Mechanisms Examined by Measured Human Arm Stiffness and EMG Signals
Osu, R., & Gomi, H. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.81.4.1458 · Cited by 229 · see citing works
An EMG-Controlled Hand Exoskeleton for Natural Pinching
Lucas, L., DiCicco, M., & Matsuoka, Y. (2004) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2004.p0482 · Cited by 194 · see citing works
Pattern recognition of number gestures based on a wireless surface EMG system
Chen, X., & Wang, Z. J. (2012) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2012.08.005 · Cited by 167 · see citing works
Bu, N., Okamoto, M., & Tsuji, T. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2019782 · Cited by 159 · see citing works
A real-time EMG-driven virtual arm
MANAL, K. T., Gonzalez, R. V., Lloyd, D. G., et al. (2002) · Computers in Biology and Medicine · doi:10.1016/s0010-4825(01)00024-5 · Cited by 153 · see citing works
A Switching Regime Model for the EMG-Based Control of a Robot Arm
Artemiadis, P., & Kyriakopoulos, K. J. (2010) · IEEE Transactions on Systems Man and Cybernetics Part B (Cybernetics) · doi:10.1109/tsmcb.2010.2045120 · Cited by 142 · see citing works
Hand Motion Classification Using a Multi-Channel Surface Electromyography Sensor
Tang, X., Liu, Y., Lv, C., & Sun, D. B. (2012) · Sensors · doi:10.3390/s120201130 · Cited by 87 · see citing works
Cavallaro, E., Rosén, J., Perry, J. C., Burns, S. P., & Hannaford, B. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2005.1570815 · Cited by 81 · see citing works
Development of an upper extremity motor function rehabilitation system and an assessment system
Song, Z., Guo, S., & Fu, Y. (2011) · International Journal of Mechatronics and Automation · doi:10.1504/ijma.2011.039152 · Cited by 75 · see citing works
Self-citationLearning human reach-to-grasp strategies: Towards EMG-based control of robotic arm-hand systems
Liarokapis, M., Artemiadis, P. K., Katsiaris, P., Kyriakopoulos, K., & Manolakos, E. (2012) · IEEE International Conference on Robotics and Automation · doi:10.1109/icra.2012.6225047 · Cited by 74 · see citing works
Hand movement recognition based on biosignal analysis
Wojtczak, P., Amaral, T. G., Dias, O. P., et al. (2009) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2008.12.004 · Cited by 51 · see citing works
Phinyomark, A., Quaine, F., Charbonnier, S., Servière, C., Tarpin-Bernard, F., & Laurillau, Y. (2013) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2013.01.004 · Cited by 31 · see citing works
Study on the sEMG Driven Upper Limb Exoskeleton Rehabilitation Device in Bilateral Rehabilitation
Pang, M., Guo, S., & Song, Z. (2012) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2012.p0585 · Cited by 30 · see citing works
Self-citationKnee angle-specific EMG normalization: the use of polynomial based EMG-angle relationships.
Earp, J. E., Newton, R., Cormie, P., & Blazevich, A. (2013) · Journal of Electromyography & Kinesiology · doi:10.1016/j.jelekin.2012.08.015 · Cited by 26 · see citing works
sEMG signal and hill model based continuous prediction for hand grasping motion
Pang, M., Guo, S., Song, Z., et al. (2013) · ICME International Conference on Complex Medical Engineering (CME) · doi:10.1109/iccme.2013.6548264 · Cited by 9 · see citing works
Self-citationEstimation of multijoint limb stiffness from EMG during reaching movements
Franklin, D. W., Leung, F., Kawato, M., & Milner, T. E. (2004) · IEEE EMBS Asian-Pacific Conference on Biomedical Engineering · doi:10.1109/apbme.2003.1302664 · Cited by 9 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Bi, L., Feleke, A. >., & Guan, C. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.02.011 · Cited by 418 · see citing works
Motion capture sensing techniques used in human upper limb motion: a review
Yahya, M., Shah, J. A., Kadir, K. A., Yusof, Z. M., Khan, S., & Warsi, A. (2019) · Sensor Review · doi:10.1108/sr-10-2018-0270 · Cited by 82 · see citing works
Jeong, H., Kwak, S. S., Sohn, S., Lee, J. Y., Lee, Y. J., O’Brien, M. K., Park, Y., Avila, R., Kim, J.-T., Yoo, J.-Y., et al. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2104925118 · Cited by 59 · see citing works
“Alternative strategies for high-resolution analysis of an infant’s motor development involve quantitative data from digital imaging systems or commercial wearable sensors packages (11–15), often also with electroencephalography (16) or electromyography (17).”
BackgroundEMG and Joint Angle-Based Machine Learning to Predict Future Joint Angles at the Knee
Coker, J., Chen, H., Schall, M. C., Gallagher, S., & Zabala, M. (2021) · Sensors · doi:10.3390/s21113622 · Cited by 56 · see citing works
- Authors
- Pang, M., Guo, S., Huang, Q., Ishihara, H., & Hirata, H.
- Affiliations
- Kagawa University (JP)
- Beijing Institute of Technology (CN)
- Corresponding author
- Guo, Shuxiang
- Venue
- Journal of Medical and Biological Engineering
- Published
- 2015-04
- Volume
- 35
- Issue
- 2
- Pages
- 165-177
- ISSN
- 1609-0985 (ISSN-L)
- 2199-4757
- PMC
- PMC4414936
- OpenAlex
- W2160601648
- Cited by
- 53
- References
- 28
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 5 · 2023: 4 · 2022: 4 · 2021: 5 · 2020: 4 · 2019: 7 · 2018: 6 · 2017: 4 · 2016: 6 · 2015: 2
- FWCI
- 2.98
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Journal of Medical and Biological Engineering (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Control and Systems Engineering › Human Motion and Animation
- Keywords
- electromyography, biceps brachii, Hill-type muscle model, musculoskeletal model, exoskeleton control, sagittal plane motion, stepping test
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review