CoChat

An eco-friendly and sensitive deep eutectic solvent-based liquid-phase microextraction procedure for extraction preconcentration of Pb (II) ions

Aracier, Esra Duygu, Kök Yetimoğlu, Ece, Aydın Urucu, Oya · 2023 · Analytical Sciences

The DOI matches its Crossref record; 33 of the 34 references it cites were found in a registry or an index.

Abstract

In recent years, interest in green solvents, which are environmentally friendly, easy to prepare and biodegradable, and in their applications in chemistry has considerably increased. In the current study, a new and easy deep eutectic solvent-based liquid-phase microextraction method compatible with green chemistry principles was developed for preconcentration of Pb (II) ions. The amount of Pb (II) ions was determined with graphite furnace atomic absorption spectrometry (GFAAS). Various analytical parameters such as deep eutectic solvent (DES) ratio and amount, ligand amount, pH, sample volume were optimized and the effects of potential matrix ions on the method were investigated. The preconcentration factor of the method was found to be 160, while the limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.071 µg L^−1 and 0.236 µg L^−1, respectively. The developed procedure was performed to determine Pb (II) ions in lake and river waters, and the accuracy of the procedure was determined with certified reference wastewater (SPS-WW1) analysis. Graphical abstract

Overview

Integrity signals

Registry

Crossref · 10.1007/s44211-023-00315-7

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 33 references

Research works printed but not linked: 2

  1. M.A. Taher, Bull. Chem. Soc. Ethiop. 17(2), 129–138 (2003)
  2. W. Guo, W. Liu, S. Jin, S. Hu, H. Zhang, Y. Peng, 2nd International Conference on Bioinformatics and Biomedical Engineering, (2008).

Metadata

Authors
Aracier, E. D., Kök Yetimoğlu, E., & Aydın Urucu, O.
Affiliations
Marmara University (TR)
Venue
Analytical Sciences
Published
2023-03-25
Volume
39
Issue
7
Pages
1065-1071
ISSN
  • 0910-6340 (ISSN-L)
  • 1348-2246
OpenAlex
W4360820714
Cited by
14
References
34
Citations by year
2026: 3 · 2025: 3 · 2024: 4 · 2023: 4
FWCI
1.79
Type
journal article
Language
en
Open access
closed
Licence
Locations
  • Analytical Sciences (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
  • Physical Sciences › Materials Science › Metals and Alloys › Extraction and Separation Processes
Keywords
deep eutectic solvents, liquid-phase microextraction, lead preconcentration, green solvents, graphite furnace atomic absorption spectrometry, lake water analysis, river water analysis, wastewater analysis, matrix effects

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An eco-friendly and sensitive deep eutectic solvent-based liquid-phase microextraction procedure for extraction preconcentration of Pb (II) ions. https://app.cochat.ai/papers/10.1007/s44211-023-00315-7
The paper
Aracier, E. D., Kök Yetimoğlu, E., & Aydın Urucu, O. (2023). An eco-friendly and sensitive deep eutectic solvent-based liquid-phase microextraction procedure for extraction preconcentration of Pb (II) ions. Analytical Sciences. https://doi.org/10.1007/s44211-023-00315-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.