The DOI matches its Crossref record; 23 of the 24 references it cites were found in a registry or an index.
Accuracy of subcutaneous fat measurement: Comparison of skinfold calipers, ultrasound, and computed tomography
Abstract
Objective The purpose of this study was to compare skinfold caliper and ultrasound measurement of subcutaneous body fat at three abdominal sites with computed tomography, which is considered to be the gold standard.Design This was a cross-sectional study in which computed-tomography, ultrasound, and skinfold caliper measurements were made at three distinct abdominal sites. All body composition and anthropometric measurements were performed on each subject on one occasion.Subjects Twenty-two subjects were recruited (13 men and 9 women). Mean ages (+/- standard deviation) were 43 +/- 4 years for the women and 51 +/- 18 years for the men. All subjects had been previously scheduled for an abdominal or pelvic computed-tomography scan at the Department of Radiology, St Paul's Hospital, Vancouver, British Columbia, Canada, and participated in the study on a volunteer basis.Main outcome measures A better agreement was found between the skinfold calipers and computed-tomography methods than between the ultrasound and computed-tomography method for the measurement of subcutaneous body fat. This was observed when the data were analyzed for both correlational agreement and for graphical interpretation.Statistical analyses performed The relationships among skinfold, ultrasound, and computed-tomography measurements were analyzed by determining Pearson correlation coefficients. A graphical method described by Bland and Altman was also used to assess agreement among the three methods.Results Significant correlation coefficients were observed between skinfold calipers and computed tomography at all three abdominal sites (site 1, r = .60, P = .003; site 2, r = .70, P = .0001; site 3, r = .73, P = .0001). Ultrasound and computed-tomography methods only showed a significant correlation at site 3 (r = .54; P = .009). The graphical method revealed that the variation in the ultrasound measurements was much greater than that of the skinfold measurements when compared to computed-tomography values.Applications/conclusions The results of this study indicated that relative agreement in the measurement of subcutaneous body fat between skinfold and computed-tomography measurements was superior to that exhibited between ultrasound and computed-tomography measurements. This finding enhances the potential use of skinfold calipers in the clinical setting, particularly in view of the fact that measurement of subcutaneous body fat at different body sites is becoming increasingly important for the characterization of risk of certain disease states.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This coincides with the literature, as Harpenden is the most traditionally used model in scientific research, being considered the gold standard method [93,94].”
From Body Composition of Male Professional Soccer Players Using Different Measurement Methods: A Systematic Review and Meta-Analysis (2023) · cites this paper as [94]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Beckett, A. H., Rowland, M., & TURNER, P. (1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,917
Relation of Body Fat Distribution to Metabolic Complications of Obesity*
KISSEBAH, A. H., VYDELINGUM, N., MURRAY, R., EVANS, D. J., KALKHOFF, R. K., & ADAMS, P. W. (1982) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-54-2-254 · Cited by 1,909
Krotkiewski, M., Björntorp, P. A., Sjöström, L., & Smith, U. (1983) · Journal of Clinical Investigation · doi:10.1172/jci111040 · Cited by 1,475
Kvist, H., Chowdhury, B., Grangård, U., Tylén, U., & Sjöström, L. (1988) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/48.6.1351 · Cited by 794
Recent Advances in Obesity Research
Bray, G. A. (1979) · Cited by 610
Techniques for the measurement of visceral fat: a practical guide.
van der Kooy, K., & Seidell, J. C. (1993) · PubMed · Cited by 535
Ashwell, M., Cole, T. J., & Dixon, A. K. (1985) · BMJ · doi:10.1136/bmj.290.6483.1692 · Cited by 401
Evans, D. J., Hoffman, R. G., Kalkhoff, R. K., & Kissebah, A. H. (1984) · Metabolism · doi:10.1016/0026-0495(84)90164-1 · Cited by 389
Ferland, M., Després, J., Tremblay, A., Pinault, S., Nadeau, A., Moorjani, S., Lupien, P. J., Thériault, G., & Bouchard, C. (1989) · British Journal Of Nutrition · doi:10.1079/bjn19890104 · Cited by 349
Gillum, R. F. (1987) · Journal of Chronic Diseases · doi:10.1016/0021-9681(87)90175-5 · Cited by 219
Body fat distribution, plasma lipids, and lipoproteins.
Anderson, A. J., Sobocinski, K. A., Freedman, D. S., Barboriak, J. J., Rimm, A. A., & Gruchow, H. W. (1988) · Arteriosclerosis An Official Journal of the American Heart Association Inc · doi:10.1161/01.atv.8.1.88 · Cited by 165
Techniques for the measurement of body composition: a practical guide.
Jebb, S. A., & Elia, M. (1993) · PubMed · Cited by 155
Prediction of body fat by skinfold caliper: assumptions and cadaver evidence.
Martin, A. D., Ross, W. D., Drinkwater, D. T., & Clarys, J. P. (1985) · PubMed · Cited by 146
Booth, R. A. D., Goddard, B. A., & Paton, A. (1966) · British Journal Of Nutrition · doi:10.1079/bjn19660073 · Cited by 135
Use of anthropometric measures to assess weight loss
Bray, G. A., Greenway, F. L., Molitch, M. E., Dahms, W. T., Atkinson, R. L., & Hamilton, K. (1978) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/31.5.769 · Cited by 117
Ultrasound as an approach to assessing body composition
Fanelli, M. T., & Kuczmarski, R. J. (1984) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/39.5.703 · Cited by 113
Comparison of ultrasound and skinfold measurements in assessment of subcutaneous and total fatness
Borkan, G. A., Hults, D. E., Cardarelli, J. A., & Burrows, B. A. (1982) · American Journal of Physical Anthropology · doi:10.1002/ajpa.1330580309 · Cited by 105
Kuczmarski, R. J., Fanelli, M. T., & Koch, G. G. (1987) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/45.4.717 · Cited by 98
Black, D., Vora, J. P., Hayward, M., & Marks, R. (1988) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/9/1/005 · Cited by 34
Measurement of subcutaneous adipose tissue using ultrasound images
Ramirez, M. E. (1992) · American Journal of Physical Anthropology · doi:10.1002/ajpa.1330890308 · Cited by 32
Evaluation of a portable ultrasonoscope in assessing the body composition of college-age women
VOLZ, P. A., & Ostrove, S. M. (1984) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198401000-00020 · Cited by 28
Wertheimer, E. (1954) · PubMed · Cited by 9
Cited by
Sorted by citations
Nordander, C., Willner, J., Hansson, G.-Å., Larsson, B. K., Unge, J., Granquist, L., & Skerfving, S. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0819-1 · Cited by 216
Liu, K. H., Chan, E., Chan, J. C. N., Kong, W., Kong, M., & Chan, J. C. N. (2003) · International Journal of Obesity · doi:10.1038/sj.ijo.0802398 · Cited by 139
Using quantitative CT to assess adipose distribution in adult men with acquired hypogonadism.
Katznelson, L. J., Rosenthal, D. I., Rosol, M. S., Anderson, E. J., Hayden, D. L., Schoenfeld, D., & Klibanski, A. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.170.2.9456958 · Cited by 95
Reimers, C. D., Harder, T., & Saxe, H. (1998) · Journal of the Neurological Sciences · doi:10.1016/s0022-510x(98)00134-8 · Cited by 89
Gualtieri, P., Falcone, C., Romano, L., Macheda, S., Correale, P., Arciello, P., Polimeni, N., & LORENZO, A. D. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21134670 · Cited by 74
Metadata
- Authors
- Orphanidou, C., McCargar, L., Birmingham, C. L., Mathieson, J., & Goldner, E.
- Affiliations
- University of British Columbia (CA)
- St. Paul's Hospital (CA)
- Corresponding author
- McCargar, Linda
- ORCID
- Birmingham, C.Laird
- Venue
- Journal of the American Dietetic Association
- Publisher
- Elsevier BV
- Published
- 1994-08
- Volume
- 94
- Issue
- 8
- Pages
- 855-858
- ISSN
- 0002-8223 (ISSN-L)
- OpenAlex
- W2049343210
- Cited by
- 132
- References
- 24
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 1 · 2023: 14 · 2022: 5 · 2021: 2 · 2020: 5 · 2019: 7 · 2018: 2 · 2017: 1 · 2016: 3 · 2015: 7 · 2014: 1 · 2013: 4 · 2012: 5
- FWCI
- 0.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the American Dietetic Association (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Body Composition Measurement Techniques
- Health Sciences › Medicine › Surgery › Body Contouring and Surgery
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Keywords
- skinfold caliper, ultrasound, computed tomography, abdominal fat, measurement agreement, body composition, anthropometry, method comparison, Bland-Altman analysis
- MeSH terms
- Abdomen, Adipose Tissue, Adult, Aged, Aged, 80 and over, Anthropometry, Body Composition, Cross-Sectional Studies, Female, Humans, Male, Middle Aged, Pilot Projects, Skin, Skinfold Thickness, Tomography, X-Ray Computed, Ultrasonography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review