The DOI matches its Crossref record.
Hematocrit, plasma protein, plasma volume, and viscosity in early hypertensive disease
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Direct relationship between blood pressure and blood viscosity in normal and hypertensive subjects
Letcher, R. L., Chien, S., Pickering, T. G., Sealey, J. E., & Laragh, J. H. (1981) · The American Journal of Medicine · doi:10.1016/0002-9343(81)90827-5 · Cited by 352
de Simone, G., Devereux, R. B., Chien, S., Alderman, M. H., Atlas, S. A., & Laragh, J. H. (1990) · Circulation · doi:10.1161/01.cir.81.1.107 · Cited by 335
Autonomic imbalance, hypertension, and cardiovascular risk
BROOK, R. (2000) · American Journal of Hypertension · doi:10.1016/s0895-7061(00)00228-4 · Cited by 257
RAINE, A. (1988) · The Lancet · doi:10.1016/s0140-6736(88)90293-0 · Cited by 256
Abnormalities of Plasma Volume in Borderline Hypertension
Julius, S. (1971) · Archives of Internal Medicine · doi:10.1001/archinte.1971.00310130120021 · Cited by 157
Metadata
- Authors
- Tibblin, G., Bergentz, S.-E., Bjure, J., & Wilhelmsen, L.
- Venue
- American Heart Journal
- Publisher
- Elsevier BV
- Published
- 1966-08
- Volume
- 72
- Issue
- 2
- Pages
- 165-176
- ISSN
- 0002-8703 (ISSN-L)
- OpenAlex
- W2035037001
- Cited by
- 161
- References
- 0
- FWCI
- 6.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hematocrit, plasma protein, plasma volume, and viscosity in early hypertensive disease. https://app.cochat.ai/papers/10.1016/0002-8703(66)90440-6
- The paper
- Tibblin, G., Bergentz, S.-E., Bjure, J., & Wilhelmsen, L. (1966). Hematocrit, plasma protein, plasma volume, and viscosity in early hypertensive disease. American Heart Journal. https://doi.org/10.1016/0002-8703(66)90440-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.