Cited by 157Blood Pressure and Hypertension StudiesCardiovascular Health and Disease PreventionHemodynamic Monitoring and Therapy

Abnormalities of Plasma Volume in Borderline Hypertension

Julius, Stevo·1971·Archives of Internal Medicine

Abstract

Patients with borderline hypertension have decreased plasma volume. This is a reproducible finding. Decreased plasma volume is associated with increases of the hematocrit reading. Increased cardiac output and heart rates were observed in borderline hypertension, but this was not associated with the decrease of the plasma volume. However, the decreased plasma volume was correlated with increases of the blood pressure and of the total peripheral resistance. Since the decrease of plasma volume clearly relates to indices of "severity" of borderline hypertension (blood pressure and resistance), measurement of plasma volume may be important for understanding the natural history of the disease and for the assessment of an individual's risks.

Integrity signals

Registry

Crossref · 10.1001/archinte.1971.00310130120021

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Julius, S.
Corresponding author
Julius, Stevo
Venue
Archives of Internal Medicine
Published
1971-01-01
Volume
127
Issue
1
Pages
116
ISSN
0003-9926 (ISSN-L)
OpenAlex
W2059295172
Cited by
157
References
12
Citations by year
2025: 1 · 2022: 1 · 2018: 3 · 2017: 3 · 2016: 10 · 2015: 1 · 2013: 17 · 2012: 18
FWCI
6.49
Type
journal article
Language
en
Open access
closed
Locations
  • Archives of Internal Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
Keywords
borderline hypertension, plasma volume, hematocrit, cardiac output, heart rate, systemic vascular resistance, blood pressure, hypertension severity, cardiovascular risk assessment
MeSH terms
Adult, Age Factors, Analysis of Variance, Blood Pressure Determination, Blood Volume Determination, Body Weight, Cardiac Output, Heart Rate, Hematocrit, Humans, Hypertension, Male, Plasma Volume, Vascular Resistance

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review