Comparison of time- and frequency domain-based measures of cardiac parasympathetic activity in Holter recordings after myocardial infarction

Open access
Bigger, J.Thomas, Albrecht, Paul, Steinman, Richard C., Rolnitzky, Linda M., Fleiss, Joseph L., Cohen, Richard J. · 1989 · The American Journal of Cardiology
Cited by 153

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

The standard deviation of normal RR intervals predicts mortality after acute myocardial infarction independently of left ventricular function and ventricular arrhythmias. 1 Myers et al 2 suggested that this measure of heart period variability is a broad-band measure composed of high and low frequency components, and suggested that patients with malignant arrhythmias have reduced power in the high frequency band of the heart period or heart rate power spectrum. The high frequency band of the heart rate power spectrum reflects vagally mediated respiratory sinus arrhythmia. 3–5 Also, 2 time domain measures—the percent of absolute differences between successive normal RR intervals that exceed 50 ms (pNN50) and the root mean square successive difference (r-MSSD)—have been used as measures of tonic vagal activity. 6 The objective of this study was to determine the strength of association among 3 measures of tonic vagal activity: the high frequency band (0.15 to 0.50 Hz) in the heart period power spectrum, pNN50 and r-MSSD. We expected strong correlations among these 3 variables, and hoped that the correlations would be strong enough to permit their interchangeable use for assessing tonic vagal activity in long duration electrocardiographic recordings. We expected weaker correlations of these 3 measures with measures of total heart rate or heart period variability, such as the standard deviation of normal RR intervals or the total power in the heart period power spectrum.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0002-9149(89)90436-0

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 153

Metadata

Authors
Bigger, J. T., Albrecht, P., Steinman, R. C., Rolnitzky, L. M., Fleiss, J. L., & Cohen, R. J.
Venue
The American Journal of Cardiology
Publisher
Elsevier BV
Published
1989-09
Volume
64
Issue
8
Pages
536-538
ISSN
0002-9149 (ISSN-L)
OpenAlex
W2054340269
Cited by
153
References
4
FWCI
5.95
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of time- and frequency domain-based measures of cardiac parasympathetic activity in Holter recordings after myocardial infarction. https://app.cochat.ai/papers/10.1016/0002-9149(89)90436-0
The paper
Bigger, J. T., Albrecht, P., Steinman, R. C., Rolnitzky, L. M., Fleiss, J. L., & Cohen, R. J. (1989). Comparison of time- and frequency domain-based measures of cardiac parasympathetic activity in Holter recordings after myocardial infarction. The American Journal of Cardiology. https://doi.org/10.1016/0002-9149(89)90436-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.