Impact of heart rate and PR interval on Doppler indexes of left ventricular diastolic filling in an elderly cohort (the Framingham Heart Study)

Open access
Galderisi, Maurizio, Benjamin, Emelia J., Evans, Jane C., D'Agostino, Ralph B., Fuller, Deborah L., Lehman, Brigitta, Levy, Daniel · 1993 · The American Journal of Cardiology
Cited by 69

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The relations of heart rate and PR interval to Doppler-derived diastolic indexes were examined in 260 men (mean age 75 years) and 462 women (mean age 76 years) from the Framingham Heart Study. Subjects receiving any antihypertensive or cardiac medications were excluded from eligibility; those with mitral stenosis or prosthesis, pacemaker, atrial fibrillation, arrhythmia, left bundle branch block, congestive heart failure, previous myocardial infarction, and technically inadequate Doppler study were also excluded. Peak velocity of early (E) and late (A) diastolic left ventricular (LV) filling, ratio of peak velocities E/A, ratio of time velocity integrals E/A, and atrial filling fraction were studied by multivariable analyses adjusting for age, sex, blood pressure, heart rate and PR interval. Heart rate was a major determinant of all 5 Doppler indexes of diastolic filling; heart rate was inversely associated with peak velocity E, E/A, and time velocity integral E/A, and was directly associated with peak velocity A and atrial filling fraction. PR interval was inversely associated with time velocity integral E/A (p < 0.01) and directly associated with atrial filling fraction. The results were largely unaltered after further adjustment for LV wall thickness, LV end-diastolic diameter and left atrial diameter (in addition to age, sex and blood pressure). Heart rate and PR interval are independent contributors to Doppler-assessed LV diastolic filling in the elderly. The atrial contribution to LV filling depends on its timing in the cardiac cycle and on heart rate. Failure to account for heart rate and PR interval may lead to inappropriate assessment of Doppler diastolic filling.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0002-9149(93)90991-k

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 69

Metadata

Authors
Galderisi, M., Benjamin, E. J., Evans, J. C., D'Agostino, R. B., Fuller, D. L., Lehman, B., & Levy, D.
Venue
The American Journal of Cardiology
Publisher
Elsevier BV
Published
1993-11
Volume
72
Issue
15
Pages
1183-1187
ISSN
0002-9149 (ISSN-L)
OpenAlex
W2116564435
Cited by
69
References
1
FWCI
1.87
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of heart rate and PR interval on Doppler indexes of left ventricular diastolic filling in an elderly cohort (the Framingham Heart Study). https://app.cochat.ai/papers/10.1016/0002-9149(93)90991-k
The paper
Galderisi, M., Benjamin, E. J., Evans, J. C., D'Agostino, R. B., Fuller, D. L., Lehman, B., & Levy, D. (1993). Impact of heart rate and PR interval on Doppler indexes of left ventricular diastolic filling in an elderly cohort (the Framingham Heart Study). The American Journal of Cardiology. https://doi.org/10.1016/0002-9149(93)90991-k

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.