Objective We investigated the effects of thyroxine (T4) therapy on the cardiac function in subclinical hypothyroidism (SHT) by using the index of myocardial performance (IMP) and the conventional echocardiographic parameters.Methods Forty-five SHT patients (F/M:38/7, age 39.9+/-7.9) and 29 healthy subjects (F/M:25/4, age 38.3+/-8.6) were studied. Patients were randomly assigned, in a double-blind manner to receive T4 therapy (group I) or a placebo (group II) and for a period of up to 12 months, were followed up using thyroid function tests and both conventional and Doppler echocardiographic measurements.Results At the baseline, the SHT patients has a significantly higher isovolumic relaxation time (IRT) (98.3+/-23.7 vs. 81.7+/-14.7<0.01), IMP (0.52+/-0.06 vs. 0.42+/-0.05; P<0.001), A max (late mitral peak velocity) (83.4+/-12.6 vs. 74.3+/-13.5; P<0.01) and significantly lower (early mitral peak velocity) Emax/Amax ratio (1.19+/-0.18 vs. 1.34+/-0.17; P<0.01) than the individuals in the control group. In group I, the thyroid hormone profile became normalized after 1 year of L-T4 therapy, but there was no significant change in the left ventricular (LV) morphology or systolic function. After 1 year of follow-up, group I showed a significant reduction of MPI (0.53+/-0.05 vs. 0.42+/-0.07; P<0.001), Amax (84.2+/-13.7 vs. 74.5+/-11; P<0.001) and IRT (98.6+/-23.7 vs. 82.9+/- 23.3; P<0.001) along with a normalization of the E/A ratio (1.17+/-0.16 vs. 1.33+/-0.19; P<0.001). Conversely, no change was observed in group II.Conclusions An impairment of left ventricular diastolic function, which may be reversible with T4 therapy, was observed in the SHT patients, and IMP may be useful in the evaluation of LV myocardial dysfunction in these patients.

Integrity signals

Registry

Crossref · 10.1016/j.ijcard.2003.05.015

Cites

54 of 54 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Yazici, M., Gorgulu, S., Sertbas, Y., Erbilen, E., Albayrak, S., Yildiz, O., & Uyan, C.
Affiliations
Düzce Üniversitesi (TR)
Venue
International Journal of Cardiology
Publisher
Elsevier BV
Published
2004-06
Volume
95
Issue
2-3
Pages
135-143
ISSN
0167-5273 (ISSN-L)
OpenAlex
W2055238335
Cited by
99
References
54
Citations by year
2026: 1 · 2025: 1 · 2024: 3 · 2023: 7 · 2022: 2 · 2021: 2 · 2020: 9 · 2019: 4 · 2018: 6 · 2017: 1 · 2016: 2 · 2015: 5 · 2014: 6 · 2013: 12 · 2012: 5
FWCI
3.18
Type
journal article
Language
en
Open access
closed
Locations
  • International Journal of Cardiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Thyroid Disorders and Treatments
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hormonal and reproductive studies
Keywords
subclinical hypothyroidism, levothyroxine therapy, left ventricular function, isovolumic relaxation time, E/A ratio, left ventricular systolic function, left ventricular diastolic function, Doppler echocardiography, thyroid hormone replacement, left ventricular structure, thyroid function
MeSH terms
Adult, Analysis of Variance, Double-Blind Method, Female, Heart, Humans, Hypothyroidism, Male, Thyroxine, Echocardiography, Doppler, Ventricular Function, Left

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review