Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 214

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Amniotic fluid white blood cell count: A rapid and simple test to diagnose microbial invasion of the amniotic cavity and predict preterm delivery

Open access
Romero, Roberto, Quintero, Ruben, Nores, Jose, Avila, Cecilia, Mazor, au]Moshe, Hanaoka, Shuichi, Hagay, Zion, Merchant, Lydia, Hobbins, John C.·1991·American Journal of Obstetrics and Gynecology

Abstract

The purpose of this study was to determine the value of amniotic fluid white blood cell count in the diagnosis of microbial invasion of the amniotic cavity. Amniotic fluid was retrieved by amniocentesis from 195 patients with preterm labor and intact membranes. Fluid was cultured for aerobic and anaerobic bacteria, as well as for mycoplasmas. The prevalence of a positive amniotic fluid culture was 12.8% (25/195). Patients with a positive amniotic fluid culture had a significantly higher median amniotic fluid white blood cell count than did patients with a negative amniotic fluid culture (median, 6 cells/mm3; range, 0 to 11,000 cells/mm3 vs median, 320 cells/mm3; range, 1 to 4480 cells/mm3; p less than 0.0001). An amniotic fluid white blood cell count greater than or equal to 50 cells/mm3 had a sensitivity of 80% (20/25), a specificity of 87.64% (149/170), a positive predictive value of 48.78% (20/41), and a negative predictive value of 96.75% (149/154) in the detection of a positive amniotic fluid culture for microorganisms. Although the sensitivity of an amniotic fluid white blood cell count (greater than or equal to 50 cells/mm3) in the detection of microbial invasion of the amniotic cavity was greater than that of the Gram stain of amniotic fluid (80% [20/25] vs 48% [12/25]; p less than 0.05), the specificity was lower (87.64% [149/170] vs 98.8% [168/170]; p less than 0.05). However, 88% (15/17) of all patients with an amniotic fluid white blood cell count greater than or equal to 50 cells/mm3 and a negative amniotic fluid culture had a spontaneous preterm delivery. We conclude that the amniotic fluid white blood cell count is a sensitive, simple, and inexpensive test for the detection of microbial invasion of the amniotic cavity. An elevated amniotic fluid white blood cell count is a risk factor for preterm delivery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0002-9378(91)90423-o

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 214

Metadata

Authors
Romero, R., Quintero, R., Nores, J., Avila, C., Mazor, A., Hanaoka, S., Hagay, Z., Merchant, L., & Hobbins, J. C.
Venue
American Journal of Obstetrics and Gynecology
Publisher
Elsevier BV
Published
1991-10
Volume
165
Issue
4
Pages
821-830
ISSN
0002-9378 (ISSN-L)
OpenAlex
W2024768515
Cited by
214
References
1
FWCI
6.26
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Amniotic fluid white blood cell count: A rapid and simple test to diagnose microbial invasion of the amniotic cavity and predict preterm delivery. https://app.cochat.ai/papers/10.1016/0002-9378(91)90423-o
The paper
Romero, R., Quintero, R., Nores, J., Avila, C., Mazor, A., Hanaoka, S., Hagay, Z., Merchant, L., & Hobbins, J. C. (1991). Amniotic fluid white blood cell count: A rapid and simple test to diagnose microbial invasion of the amniotic cavity and predict preterm delivery. American Journal of Obstetrics and Gynecology. https://doi.org/10.1016/0002-9378(91)90423-o

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.