Cited by 160Neuroscience and Neural EngineeringMuscle activation and electromyography studiesVagus Nerve Stimulation Research

Stable long-term recordings from cat peripheral nerves

Stein, R.B., Nichols, T.R., Jhamandas, J., Davis, L., Charles, D.·1977·Brain Research

Abstract

A procedure has been developed for the stable long-term recording of nerve signals in unanesthetized mammals, which should have wide application in basic research on the nervous system and also in clinical areas such as the derivation of control signals for powered prostheses. Methods are fully described for constructing devices consisting of (1) Silastic nerve cuffs containing three or more electrodes, (2) coiled leads insulated with Silastic which extend from the cuffs to an integrated circuit socket, (3) a vitreous carbon transcutaneous connector which surrounds the integrated circuit socket and makes a good interface with the skin. Neural activity has been recorded from mammalian nerves for many months during normal behaviour. The peak-to-peak amplitude and latency of the recorded compound action potentials remain stable and may continue at a constant level more or less indefinitely. A tripolar recording configuration between a central lead and the two end leads, which are connected together, permits good rejection of EMG signals from surrounding muscles. The amplitude of single unit potentials increases as the square of the conduction velocity of the nerve fibre. Thus, the largest nerve fibres will dominate the signals recorded during behaviour. The reasons for premature termination of a few experiments are given together with methods for overcoming these problems. For example, platinum-iridium electrodes remain relatively stable, whereas silver wires tend to fracture af…

Integrity signals

Registry

Crossref · 10.1016/0006-8993(77)90233-5

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Chronically implanted tripolar cuff electrodes in animals can be used for long-term recording of both afferent and efferent nerve activity.

    “Research in animals with chronically implanted tripolar cuff electrodes showed that they can be used for long-term recording of both afferent and efferent nerve activity (Stein et al., 1977; Popovic et al., 1993; Hoffer and Kallesøe, 2001) .”
  • A tripolar electrode configuration is preferred to reduce noise pickup and provides a biophysically ideal way to use a differential amplifier to reject large bioelectric signals arising outside the cuff.

    “Tripolar (central active electrode vs. two reference electrodes near the ends of the cuff) electrode configuration is preferred to reduce noise pickup (Stein et al., 1977) ; it provides a biophysically ideal way to use a differential amplifier to reject almost completely the large bioelectric signals arising from outside the cuff (e.g., EMG).”

No citation lists for this paper

No citation lists for this paper yet — checked again daily.

References 14 · Cited by 160

Authors
Stein, R. B., Nichols, T. R., Jhamandas, J., Davis, L., & Charles, D.
Affiliations
University of Alberta (CA)
Venue
Brain Research
Publisher
Elsevier BV
Published
1977-06
Volume
128
Issue
1
Pages
21-38
ISSN
0006-8993 (ISSN-L)
OpenAlex
W2066512184
Cited by
160
References
14
Citations by year
2026: 1 · 2024: 1 · 2023: 1 · 2022: 3 · 2021: 5 · 2020: 1 · 2019: 2 · 2018: 4 · 2017: 4 · 2016: 4 · 2015: 5 · 2014: 1 · 2013: 9 · 2012: 1
FWCI
1.59
Type
journal article
Language
en
Open access
closed
Locations
  • Brain Research (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
Keywords
peripheral nerves, compound action potential, electrode stability, platinum-iridium electrodes, conduction velocity, powered prostheses, cats
MeSH terms
Action Potentials, Animals, Cats, Electrodes, Electromyography, Neurophysiology, Peripheral Nerves, Time Factors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review