The DOI matches its Crossref record.
Microvascular and tissue oxygen distribution
Abstract
Understanding of oxygen delivery by the microcirculation has been dominated by the unitary component analysis of Krogh and Erlangen focussed on oxygen transport mediated by single capillaries, oxygenation of tissue as a whole being extrapolated from findings on oxygen exchange in these vessels. This analysis is under revision since capillaries are not sole sources of oxygen. It is increasingly apparent that arterioles are a significant equivalent source, while venules may serve as sinks for capillary and arteriolar oxygen. As a consequence detailed descriptions of the architecture of the microcirculation based on the tissue cylinder conceptualization does not yield new information given the non-exclusive role of capillaries as purveyors of oxygen to tissue. In the present study we investigate how tissue is oxygenated directly from the arteriolar supply on the basis of current results with newly developed optical techniques for the measurement of local intra- and extravascular pO2 by phosphorescence decay. This methodology shows that tissue regions between arterioles and venules have essentially uniform tissue pO2. The only experimentally detectable gradients in pO2 are those present in the immediate vicinity of arterioles. Findings on vascular longitudinal gradients are used to devise a model that links convective and diffusive processes, showing how blood viscosity, blood oxygen-carrying capacity and the slope of the oxygen dissociation curve are linked in determining intravascular and tissue pO2. The integrated approach provides a numerical basis for interpreting consequences of alterations in transport properties of blood applicable to the field of blood substitutes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Blood Flow Regulation by S -Nitrosohemoglobin in the Physiological Oxygen Gradient
Stamler, J. S., Jia, L., Eu, J. P., McMahon, T. J., Demchenko, I. T., Bonaventura, J., Gernert, K., & Piantadosi, C. A. (1997) · Science · doi:10.1126/science.276.5321.2034 · Cited by 1,050
Riess, J. G. (2001) · Chemical Reviews · doi:10.1021/cr970143c · Cited by 773
Nitric Oxide and Mitochondrial Signaling: From Physiology to Pathophysiology
Erusalimsky, J. D., & Moncada, S. (2007) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.107.151167 · Cited by 336
Keeley, T. P., & Mann, G. E. (2019) · Physiological Reviews · doi:10.1152/physrev.00041.2017 · Cited by 329
Geometric control of vascular networks to enhance engineered tissue integration and function
Baranski, J. D., Chaturvedi, R. R., Stevens, K. R., Eyckmans, J., Carvalho, B., Solorzano, R. D., Yang, M. T., Miller, J. S., Bhatia, S. N., & Chen, C. S. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1217796110 · Cited by 267
Metadata
- Authors
- Intaglietta, M.
- Venue
- Cardiovascular Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-10
- Volume
- 32
- Issue
- 4
- Pages
- 632-643
- ISSN
- 0008-6363 (ISSN-L)
- OpenAlex
- W2046025881
- Cited by
- 293
- References
- 0
- FWCI
- 18.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microvascular and tissue oxygen distribution. https://app.cochat.ai/papers/10.1016/0008-6363(96)00110-1
- The paper
- Intaglietta, M. (1996). Microvascular and tissue oxygen distribution. Cardiovascular Research. https://doi.org/10.1016/0008-6363(96)00110-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.