Microvascular and tissue oxygen distribution
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Understanding of oxygen delivery by the microcirculation has been dominated by the unitary component analysis of Krogh and Erlangen focussed on oxygen transport mediated by single capillaries, oxygenation of tissue as a whole being extrapolated from findings on oxygen exchange in these vessels. This analysis is under revision since capillaries are not sole sources of oxygen. It is increasingly apparent that arterioles are a significant equivalent source, while venules may serve as sinks for capillary and arteriolar oxygen. As a consequence detailed descriptions of the architecture of the microcirculation based on the tissue cylinder conceptualization does not yield new information given the non-exclusive role of capillaries as purveyors of oxygen to tissue. In the present study we investigate how tissue is oxygenated directly from the arteriolar supply on the basis of current results with newly developed optical techniques for the measurement of local intra- and extravascular pO2 by phosphorescence decay. This methodology shows that tissue regions between arterioles and venules have essentially uniform tissue pO2. The only experimentally detectable gradients in pO2 are those present in the immediate vicinity of arterioles. Findings on vascular longitudinal gradients are used to devise a model that links convective and diffusive processes, showing how blood viscosity, blood oxygen-carrying capacity and the slope of the oxygen dissociation curve are linked in determining intravascular and tissue pO2. The integrated approach provides a numerical basis for interpreting consequences of alterations in transport properties of blood applicable to the field of blood substitutes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Krogh, A. (1919) · The Journal of Physiology · doi:10.1113/jphysiol.1919.sp001839 · Cited by 1,426
Determinants of tumor blood flow: a review.
Jain, R. K. (1988) · PubMed · Cited by 1,379
An optical method for measurement of dioxygen concentration based upon quenching of phosphorescence.
Vanderkooi, J. M., Maniara, G., Green, T. J., & Wilson, D. F. (1987) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)45596-2 · Cited by 592
Johnson, P. C. (1986) · Circulation Research · doi:10.1161/01.res.59.5.483 · Cited by 413
Theory of oxygen transport to tissue.
Popel, A. S. (1989) · PubMed · Cited by 406
A Microelectrode for Measuring Intracellular pH1
Nair, P. K., Spande, J. I., & Whalen, W. J. (1984) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4684-4895-5_85 · Cited by 255
Torres Filho, I. P., Leunig, M., Yuan, F., Intaglietta, M., & Jain, R. K. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.6.2081 · Cited by 189
Self-citationMonitoring of Tissue Perfusion and Cellular Function
Kessler, M., Höper, J., & Krumme, B. A. (1976) · Anesthesiology · doi:10.1097/00000542-197608000-00007 · Cited by 161
The resistance to oxygen transport in the capillaries relative to that in the surrounding tissue
Hellums, J. D. (1977) · Microvascular Research · doi:10.1016/0026-2862(77)90122-4 · Cited by 159
Microvessel PO2 measurements by phosphorescence decay method
Filho, I. P. T., & Intaglietta, M. (1993) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1993.265.4.h1434 · Cited by 153
Self-citationSimulation of intraluminal gas transport processes in the microcirculation
Hellums, J. D., Nair, P. K., Huang, N. S., & Ohshima, N. (1995) · Annals of Biomedical Engineering · doi:10.1007/bf02770991 · Cited by 150
Hemoglobin-based red cell substitutes
Winslow, R. M. (1991) · Medical Entomology and Zoology · Cited by 124
Shonat, R. D., Wilson, D. F., Riva, C. E., & Pawlowski, M. (1992) · Applied Optics · doi:10.1364/ao.31.003711 · Cited by 111
Messina, E. J., Sun, D., Koller, Á., Wolin, M. S., & Kaley, G. (1994) · Microvascular Research · doi:10.1006/mvre.1994.1046 · Cited by 110
Blood substitutes : physiological basis of efficacy
Winslow, R. M., Vandegriff, K. D., & Intaglietta, M. (1995) · Birkhäuser-Verlag eBooks · Cited by 108
Self-citationInfluence of Microvascular Architecture on Oxygen Exchange in Skeletal Muscle
Pittman, R. N. (1995) · Microcirculation · doi:10.3109/10739689509146755 · Cited by 103
Evidence of flowmotion induced changes in local tissue oxygenation.
Ag, T., & Intaglietta, M. (1993) · PubMed · Cited by 99
Self-citationMeasurement of percent oxyhemoglobin in the microvasculature
Pittman, R. N., & Duling, B. R. (1975) · Journal of Applied Physiology · doi:10.1152/jappl.1975.38.2.321 · Cited by 97
Systemic and subcutaneous microvascular oxygen tension in conscious Syrian golden hamsters
Kerger, H., Filho, I. P. T., Rivas, M., Winslow, R. M., & Intaglietta, M. (1995) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1995.268.2.h802 · Cited by 96
Self-citationPawlowski, M., & Wilson, D. F. (1992) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-3404-4_21 · Cited by 92
Rate of oxygen loss from arterioles is an order of magnitude higher than expected
Popel, A. S., Pittman, R. N., & Ellsworth, M. L. (1989) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1989.256.3.h921 · Cited by 90
Effect of hemodilution on oxygen transport in arteriolar networks of hamster striated muscle
Kuo, L., & Pittman, R. N. (1988) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1988.254.2.h331 · Cited by 90
pO2Measurements in Arteriolar Networks
Filho, I. P. T., Kerger, H., & Intaglietta, M. (1996) · Microvascular Research · doi:10.1006/mvre.1996.0021 · Cited by 87
Self-citationAnalysis of oxygen diffusion from arteriolar networks
Popel, A. S., & Gross, J. F. (1979) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1979.237.6.h681 · Cited by 82
Waschke, K. F., Krieter, H., Hagen, G., Albrecht, D. M., van Ackern, K., & Kuschinsky, W. (1994) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1994.109 · Cited by 80
Иванов, К. П., Deriĭ, A. N., Vovenko, E. P., Самойлов, М. О., & Semionov, D. G. (1982) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00582403 · Cited by 75
Vinogradov, S. A., & Wilson, D. F. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80688-5 · Cited by 71
Mirhashemi, S., Ertefai, S., Meßmer, K., & Intaglietta, M. (1987) · Microvascular Research · doi:10.1016/0026-2862(87)90062-8 · Cited by 70
Self-citationAxial drift of cells and partial plasma skimming in blood flowing through glass slits
Palmer, A. A. (1965) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1965.209.6.1115 · Cited by 60
A mathematical model of countercurrent exchange of oxygen between paired arterioles and venules
Sharan, M., & Popel, A. S. (1988) · Mathematical Biosciences · doi:10.1016/0025-5564(88)90022-3 · Cited by 43
Shonat, R. D., Richmond, K. N., & Johnson, P. C. (1995) · Review of Scientific Instruments · doi:10.1063/1.1146133 · Cited by 39
Regional differences in mechanism of action of oxygen on hamster arterioles
Jackson, W. F. (1993) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1993.265.2.h599 · Cited by 31
Effect of hemodilution on oxygen transport in arteriolar networks of hamster striated muscle
Kuo, L., & Pittman, R. N. (1988) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1988.254.1.1-b · Cited by 30
Tsai, A. G., & Intaglietta, M. (1989) · Microvascular Research · doi:10.1016/0026-2862(89)90049-6 · Cited by 22
Self-citation
Cited by
Blood Flow Regulation by S -Nitrosohemoglobin in the Physiological Oxygen Gradient
Stamler, J. S., Jia, L., Eu, J. P., McMahon, T. J., Demchenko, I. T., Bonaventura, J., Gernert, K., & Piantadosi, C. A. (1997) · Science · doi:10.1126/science.276.5321.2034 · Cited by 1,050
Riess, J. G. (2001) · Chemical Reviews · doi:10.1021/cr970143c · Cited by 773
Microcirculatory oxygenation and shunting in sepsis and shock
Ince, C., & Sinaasappel, M. (1999) · Critical Care Medicine · doi:10.1097/00003246-199907000-00031 · Cited by 542
Oxygen Gradients in the Microcirculation
TSAI, A. G., JOHNSON, P. C., & INTAGLIETTA, M. (2003) · Physiological Reviews · doi:10.1152/physrev.00034.2002 · Cited by 450
Self-citationCulver, J. P., Durduran, T., Furuya, D., Cheung, C., Greenberg, J. H., & Yodh, A. G. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000076703.71231.bb · Cited by 420
Metadata
- Authors
- Intaglietta, M.
- Venue
- Cardiovascular Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-10
- Volume
- 32
- Issue
- 4
- Pages
- 632-643
- ISSN
- 0008-6363 (ISSN-L)
- OpenAlex
- W2046025881
- Cited by
- 293
- References
- 34
- FWCI
- 18.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.