The DOI matches its Crossref record.
An optical method for measurement of dioxygen concentration based upon quenching of phosphorescence.
Open accessAbstract
An optical method for measuring oxygen concentrations in aqueous solutions is described. This method is based upon the oxygen-dependent quenching of phosphorescence. Phosphorescence excitation and emission spectra and lifetimes of some of the probe molecules suitable for measurement of oxygen in aqueous solutions are given. The probes include fluorescein derivatives, 4'5'-diiodofluorescein, eosin Y, 5(and 6)-carboxyeosin, erythrosin, and 5(and 6)-carboxyerythrosin as well as the Zn(II), Y(III), Sn(IV), Lu(III), and Pd(II) derivatives of meso-tetra-(4-sulfonatophenyl)-porphine, meso-tetra-(N-methyl-4-pyridyl)-porphine and coproporphyrin. The phosphorescence lifetimes of the given probes were found to depend upon the oxygen concentration by a simple Stern-Volmer relationship with a quenching constant of approximately 10(9) M-1 S-1. Binding of the molecules to bovine serum albumin decreased the quenching constant for oxygen by approximately an order of magnitude and also inhibited probe self-quenching, indicating that at the protein binding site the probes are somewhat protected from collision with quenchers. The use of this optical method for measuring oxygen is demonstrated for reactions catalyzed by glucose oxidase and by cytochrome c oxidase. It is shown that, using this method oxygen concentrations can be measured from approximately 250 microM (air saturation) down to the nanomolar range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Why is the partial oxygen pressure of human tissues a crucial parameter? Small molecules and hypoxia
Carreau, A., Hafny‐Rahbi, B. E., Matejuk, A., Grillon, C., & Kieda, C. (2011) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2011.01258.x · Cited by 1,246
Direct measurement of local oxygen concentration in the bone marrow of live animals
Spencer, J. A., Ferraro, F., Roussakis, E., Klein, A., Wu, J., Runnels, J. M., Zaher, W., Mortensen, L. J., Alt, C., Turcotte, R., et al. (2014) · Nature · doi:10.1038/nature13034 · Cited by 1,167
Keeley, T. P., & Mann, G. E. (2019) · Physiological Reviews · doi:10.1152/physrev.00041.2017 · Cited by 329
Liu, K. J., Gast, P., Moussavi, M., Norby, S. W., Vahidi, N., Walczak, T., Wu, M., & Swartz, H. M. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.12.5438 · Cited by 318
Organs-on-chip monitoring: sensors and other strategies
Kilic, T., Navaee, F., Stradolini, F., Renaud, P., & Carrara, S. (2018) · Microphysiological Systems · doi:10.21037/mps.2018.01.01 · Cited by 96
Metadata
- Authors
- Vanderkooi, J. M., Maniara, G., Green, T. J., & Wilson, D. F.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1987-04
- Volume
- 262
- Issue
- 12
- Pages
- 5476-5482
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W2097172537
- Cited by
- 592
- References
- 0
- FWCI
- 9.73
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An optical method for measurement of dioxygen concentration based upon quenching of phosphorescence. https://app.cochat.ai/papers/10.1016/s0021-9258(18)45596-2
- The paper
- Vanderkooi, J. M., Maniara, G., Green, T. J., & Wilson, D. F. (1987). An optical method for measurement of dioxygen concentration based upon quenching of phosphorescence. Journal of Biological Chemistry. https://doi.org/10.1016/s0021-9258(18)45596-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.