Corrosion of austenitic steels in molten sulphate deposits
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The maximum corrosion rate of the three austenitic steels at ~680°C is tentatively ascribed to decomposition of Fe2(SO4)3 to Fe2O3 near 700°C, which hinders diffusion of SO3 through the molten salt to the oxide/salt interface.
“This observation is tentatively ascribed to the decomposition of Fe2(SO4)3 to Fe2O3 at a temperature near 700 o C, hindering the diffusion of SO3 through the molten salt to the oxide/salt interface [89].”
From A review on molten sulfate salts induced hot corrosion (2021) · cites this paper as [89]
Three austenitic steels (AISI 316, AISI 347 and Esshete 1250) in a simulated coal fired boiler environment have a maximum corrosion rate at ~680°C in the temperature range 600-750°C.
“in a temperature range of 600 o C -750 o C and found that all these three stainless steels have a maximum corrosion rate at ~680 o C.”
From A review on molten sulfate salts induced hot corrosion (2021) · cites this paper as [89]
Cites
Mechanisms for the hot corrosion of nickel-base alloys
Goebel, J. A., Pettit, F. S., & Goward, G. W. (1973) · Metallurgical Transactions · doi:10.1007/bf02649626 · Cited by 420 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
A review on molten sulfate salts induced hot corrosion
Hu, S., Finklea, H., & Liu, X. (2021) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2021.03.013 · Cited by 183 · see citing works
Shi, L., Zhang, Y., & Shih, S. (1992) · Oxidation of Metals · doi:10.1007/bf00665661 · Cited by 13 · see citing works
- Authors
- Hendry, A., & Lees, D. J.
- Affiliations
- Newcastle University (GB)
- Venue
- Corrosion Science
- Publisher
- Elsevier BV
- Published
- 1980-01
- Volume
- 20
- Issue
- 3
- Pages
- 383-404
- ISSN
- 0010-938X (ISSN-L)
- OpenAlex
- W2092034387
- Cited by
- 41
- References
- 1
- Citations by year
- 2025: 2 · 2024: 2 · 2023: 2 · 2022: 2 · 2021: 2 · 2019: 1 · 2018: 2 · 2017: 1 · 2016: 2 · 2015: 1 · 2014: 1 · 2013: 2 · 2012: 1
- FWCI
- 5.75
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Corrosion Science (publishedVersion)
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › High-Temperature Coating Behaviors
- Physical Sciences › Materials Science › Materials Chemistry › Corrosion Behavior and Inhibition
- Physical Sciences › Engineering › Mechanical Engineering › High Temperature Alloys and Creep
- Keywords
- fireside corrosion, austenitic stainless steel, superheater tubes, coal-fired boilers, melting behavior, heat flux, corrosion rate prediction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review