The DOI matches its Crossref record.
Rapid and uniform electromagnetic heating of aqueous cryoprotectant solutions from cryogenic temperatures
Abstract
Devitrification (ice formation during warming) is one of the primary obstacles to successful organ vitrification (solidification without ice formation). The only feasible approach to overcoming either devitrification or its damaging effects in a large organ appears at present to be the use of some form of electromagnetic heating (EH) to achieve the required high heating rates. One complication of EH in this application is the need for warming within a steel pressure vessel. We have previously reported that resonant radiofrequency (RF) helical coils provide very uniform heating at ambient temperatures and low heating rates and can be modified for coaxial power transmission, which is necessary if only one cable is to penetrate through the wall of the pressure vessel. We now report our initial studies using a modified helical coil, high RF input power, and cryogenic aqueous cryoprotectant solutions [60% (w/v) solution of 4.37 M dimethylsulfoxide and 4.37 M acetamide in water and 50% (w/w) 1,2-propanediol]. We also describe the electronic equipment required for this type of research. Temperatures were monitored during high-power conditions with Luxtron fiberoptic probes. Thermometry was complicated by the use of catheters needed for probe insertion and guidance. The highest heating rates we observed using catheters occurred at temperatures ranging from about -70 to -40 degrees C, the temperature zone where devitrification usually appears in unstable solutions during slow warming.…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Dielectric/microwave rewarming (heating of dipolar molecules by electromagnetic (EM) waves) potential rewarming volumes can approach ~100 mL in CPA systems10, including rabbit kidneys (~50 mL)11.”
From Physical vitrification and nanowarming at liter-scale CPA volumes: toward organ cryopreservation (2025) · cites this paper as [10]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 15
- Allen, 1988, CDRH RF phantom for hyperthermia systems evaluations, Int. J. Hyperthermia, 4, 17, 10.3109/02656738809032046 · DOI
- Angell, 1980, Heat capacity changes in glass-forming aqueous solutions and the glass transition in vitreous water, J. Phys. Chem, 84, 268, 10.1021/j100440a009 · DOI
- Anhalt, 1990, The CDRH helix—An in vivo evaluation, Int. J. Hyperthermia, 6, 241, 10.3109/02656739009140819 · DOI
- Bonner, 1977, Heat capacities of urea and water in water and dimethylformamide, J. Amer. Chem. Soc, 99, 2898, 10.1021/ja00451a009 · DOI
- Boutron, 1979, Stability of amorphous state in the system water-1,2-propanediol, Cryobiology, 16, 557, 10.1016/0011-2240(79)90074-9 · DOI
- Fahy, 1981, Prospects for vitrification of whole organs, Cryobiology, 18, 617, 10.1016/0011-2240(81)90150-4 · DOI
- Fahy, 1987, Vitrification of multicellular systems and whole organs, Cryobiology, 24, 580, 10.1016/0011-2240(87)90152-0 · DOI
- Fahy, 1987, Some emerging principles underlying the physical properties, biological actions, and utility of vitrification solutions, Cryobiology, 24, 196, 10.1016/0011-2240(87)90023-X · DOI
- Fahy, 1984, Vitrification as an approach to cryopreservation, Cryobiology, 21, 407, 10.1016/0011-2240(84)90079-8 · DOI · Paper page
- Fahy, 1990, Physical problems with vitrification of large systems, Cryobiology, 27, 492, 10.1016/0011-2240(90)90038-6 · DOI · Paper page
- Kiyohara, 1975, Volumes and heat capacities of dimethylsulfoxide, acetone, and acetamide in water and of some electrolytes in these mixed aqueous solvents, Canad. J. chem, 53, 3263, 10.1139/v75-465 · DOI
- MacFarlane, 1981, Homogeneous nucleation and glass formation in cryoprotective systems at high pressures, Cryo-Letters, 2, 353
- Olsen, 1989, Simple nonperturbing temperature probe for microwave/radio frequency dosimetry, Bioelectromagnetics, 10, 209, 10.1002/bem.2250100210 · DOI
- Ruggera, 1984, Development of a family of RF helical coil applicators which produce transversely uniform axially distributed heating in cylindrical fat-muscle phantoms, IEEE Trans. Biomed. Eng, BME-31, 98, 10.1109/TBME.1984.325375 · DOI
- Waterman, 1985, The response of thermometer probes inserted into catheters, Med. Phys, 12, 368, 10.1118/1.595698 · DOI
Cited by
Sorted by citations
Physical vitrification and nanowarming at liter-scale CPA volumes: toward organ cryopreservation
Gangwar, L., Han, Z., Scheithauer, C., Namsrai, B.-E., Kantesaria, S., Goldstein, R., Etheridge, M. L., Finger, E. B., & Bischof, J. C. (2025) · Nature Communications · doi:10.1038/s41467-025-63483-2 · Cited by 26
Metadata
- Authors
- Ruggera, P. S., & Fahy, G. M.
- Venue
- Cryobiology
- Publisher
- Elsevier BV
- Published
- 1990-10
- Volume
- 27
- Issue
- 5
- Pages
- 465-478
- ISSN
- 0011-2240
- Cited by
- 43
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review