Cited by 26Organ Transplantation Techniques and Outcomesnanoparticles nucleation surface interactionsTransplantation: Methods and Outcomes

The DOI matches its Crossref record; 52 of the 53 references it cites were found in a registry or an index; 2 of the 47 sources its claims cite were checked for support.

Physical vitrification and nanowarming at liter-scale CPA volumes: toward organ cryopreservation

Open access

Published version of a preprint

Abstract

Organ banking via vitrification could transform transplantation, but has never been achieved at human organ scales. This study tested vitrification and rewarming in 0.5–3 L volumes using cryoprotective agents (CPAs): M22, VS55, and 40%EG + 0.6 M Sucrose. Ice formation and cracking was avoided through optimized convective cooling, and successful vitrification was confirmed via visual inspection, thermometry, and X-ray µCT. M22 and EG+sucrose vitrified at 0.5 L, but only M22 succeeded at 3 L; VS55 failed at all volumes. Porcine livers (~0.6–1 L total volume; ~0.23–0.75 L organ volume) were also vitrified using EG+sucrose, though not rewarmed. Future experiments are needed to optimize the protocol and achieve liver rewarming. Using nanowarming with iron-oxide nanoparticles and a newly developed 120 kW RF coil, uniform rewarming was achieved in up to 2 L volumes of M22 at ~88 °C/min. This work serves as a proof-of-concept that human organ scale vitrification and rewarming is physically possible, thereby enabling human organ banking in the future.

Overview

AI snapshot

Written from the paper’s full text.

TL;DR

This study demonstrates physical vitrification of cryoprotective agent volumes up to 3 L and uniform nanowarming up to 2 L, plus vitrification of porcine livers, as a proof-of-concept for human organ cryopreservation. M22 vitrified at all tested volumes, EG+sucrose up to 1 L, VS55 failed, and nanowarming achieved ~88 °C/min in 2 L.

Key findings

  • M22 vitrified successfully at 0.5, 1, and 3 L; 40%EG + 0.6 M sucrose vitrified up to 1 L; VS55 failed at all volumes, with achieved center cooling rates of ~1.4, ~1, and ~0.5 °C/min for 0.5, 1, and 3 L, respectively, below VS55’s ~2.5 °C/min critical cooling rate.
  • Porcine livers (~0.6–1 L total volume; ~0.23–0.75 L organ volume) perfused with 40%EG + 0.6 M sucrose were vitrified, with only small ice around the portal vein and fatty perihilar tissue; they were not rewarmed.
  • A 120 kW RF coil generated up to 35 kA/m at 360 kHz, uniform within 5% over a 20 cm axial and 6 cm radial region; 1 L and 2 L M22 volumes nanowarmed at ~172 °C/min and ~88 °C/min, respectively, with temperature differences <5 °C.
  • A 1 mL VMP sample with 100 mgFe/mL EMG308 reached ~1500 °C/min, reported as the fastest measured nanowarming rate; SAR increased ~1.5-fold at cryogenic versus room temperature.

Methods

  • Heat transfer was modeled in COMSOL 5.4 for 0.5, 1, and 3 L cryobags, then vitrification used controlled-rate freezer protocols with verification by visual inspection, fiber optic thermometry, and µCT.
  • Porcine livers (n = 5) from male Yorkshire pigs (9–30 kg) were perfused via the portal vein with 40%EG + 0.6 M sucrose using a step-loading protocol and vitrified in cryobags.
  • Nanowarming used M22 with iron-oxide nanoparticles in cryobags inside a custom 120 kW RF coil, with fiber optic temperature probes; SAR was measured by the time-rise method, and experiments had ≥3 replicates.

Limitations

  • Stated: no biological or functional assessment of organs was performed; no vitrified liver was nanowarmed because of the 120 kW RF coil diameter; perfusion protocols need optimization to minimize CPA toxicity and improve consistency.
  • Stated: the study assumed full CPA equilibration in tissue, but organ perfusion often equilibrates only to ~92–94%; long-term storage effects, physical aging, devitrification, and optimal storage conditions require further study.
  • Evident from the text: this is a physical proof-of-concept only, with no transplantation, viability, or toxicity outcomes; liver rewarming and human liver-scale (≥3 L) organ rewarming remain undemonstrated.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1038/s41467-025-63483-2

Cites

52 of 52 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

2 of 47 cited sources checked · 0 supported · 0 flagged · accuracy not yet measured

  • Interpretationreasoning

    The IONP required for a single human kidney is ~0.8-1.6 gFe when the estimated amount is multiplied by ~2-4 times the vascular volume to ensure complete perfusion loading.

    “This amount should be multiplied by ~2 to 4 times the vascular volume to ensure complete perfusion loading14,15, elevating the IONP required for a single kidney to ~0.8–1.6 gFe.”
    Quote in the paperSubstantial claim1 of 2 sources checked
    • cites [14] Sharma, A. et al. Vitrification and Nanowarming of Kidneys. Adv. Sci. 8, 2101691 (2021). source
    • cites [15] Han, Z. et al. Vitrification and nanowarming enable long-term organ cryopreservation and life-sustaining kidney transplantation in a rat model. Nat. Commun. 14, 3407 (2023). source

      The Methods section, “Loading of nanoparticles” (page unavailable), describes perfusing IONPs into rat kidneys at 10 mg Fe/mL for 4–5 minutes. It does not give a 2–4-times-vascular-volume loading rule or estimate 0.8–1.6 gFe for a human kidney, so the quantitative extrapolation is not supported by this source. (LLM, conf=0.83)

      Experimental — accuracy not yet measured
  • Premisecitation

    Nanowarming of volumes up to 80 mL CPA and 30 mL biological at rates up to 50-100 °C/min has been published.

    “So far, we and others have published on nanowarming of volumes up to 80 mL CPA mL and 30 mL biological nanowarming at rates up to 50–100 °C/min14–19 (see Table S1).”
    Quote in the paperSubstantial claim1 of 6 sources checked
    • cites [14] Sharma, A. et al. Vitrification and Nanowarming of Kidneys. Adv. Sci. 8, 2101691 (2021). source
    • cites [15] Han, Z. et al. Vitrification and nanowarming enable long-term organ cryopreservation and life-sustaining kidney transplantation in a rat model. Nat. Commun. 14, 3407 (2023). source

      The Results section, “Kidney nanowarming and post-nanowarming assessment” (page not supplied), reports nanowarming a rat kidney at 72.0 ± 8.0 °C/min, within the claimed rate range. The Methods section, “Nanowarming of kidneys” (page not supplied), describes an approximately 80 mL coil bore, not 80 mL of CPA; our copy does not establish a 30 mL biological sample either. Thus this paper supports the nanowarming rate and biological-organ example, but not the claimed volumes. (LLM, conf=0.88)

      Experimental — accuracy not yet measured
    • cites [16] Zhan, T. et al. Fe3O4 nanoparticles with carboxylic acid functionality for improving the structural integrity of whole vitrified rat kidneys. ACS Appl. Nano Mater. 4, 13552–13561 (2021). source
    • cites [17] Gao, Z. et al. Vitrification and rewarming of magnetic nanoparticle-loaded rat hearts. Adv. Mater. Technol. 7, 2100873 (2022). source
    • cites [18] Chiu-Lam, A. et al. Perfusion, cryopreservation, and nanowarming of whole hearts using colloidally stable magnetic cryopreservation agent solutions. Sci. Adv. 7, eabe3005 (2021). source
    • cites [19] Sharma, A. et al. Cryopreservation of whole rat livers by vitrification and nanowarming. Ann. Biomed. Eng. 51, 566–577 (2023). source
  • Findingown data

    SARV increased at cryogenic temperature by ~1.5 times compared to room temperature.

    “Lastly, we report that SARV increased at cryogenic temperature (by ~ 1.5 times) compared to room temperature (Fig. 6B).”
    Quote in the paperNot a substantial claim
  • Findingown data

    Porcine livers perfused with 40%EG + 0.6 M sucrose were vitrified, except for a small amount of ice around the portal vein and poorly vascularized perihilar/fatty tissue.

    “Porcine livers (~0.6–1 L total volume; ~0.23–0.75 L organ volume) were also vitrified using EG+sucrose, though not rewarmed.”
    • Also stated in: § Vitrification of a human-scale organ - porcine liver · hedged
      “The liver appeared vitrified based on visual inspection, except for a small amount of ice formed around the portal vein and fatty tissue (poorly vascularized perihilar tissue), which presumably did not equilibrate fully with the CPA.”
    Quote in the paperSubstantial claim
  • Findingown data

    The calibration showed a linear relationship between applied power and field strength for the 120 kW coil.

    “The calibration showed a linear relationship between applied power and field strength (Fig. 5C) for the 120 kW coil.”
    Quote in the paperNot a substantial claim
  • It may state two separate claims as one. 21
  • The quote only partly states this claim. 1
  • Probably not a substantial claim. 20
  • It may state two separate claims as one.

    Findingown data

    Modeling predicted the center cooling rate of the porcine liver as ~4 °C/min, exceeding the CCR (~1 °C/min) of 40%EG + 0.6 M sucrose.

    “Modeling predicted the center cooling rate of the liver as ~4 °C/min, which exceeds the CCR (~1 °C/min) of 40%EG + 0.6Msucrose, which further supports vitrification (see Fig. S6).”
    Quote in the paperSubstantial claim
    • Rests on an assumption: The critical cooling rate (CCR) of 40%EG + 0.6 M sucrose is ~1 °C/min.
  • It may state two separate claims as one.

    Findingown data

    Uniform nanowarming was achieved in 1 L and 2 L volumes of M22, with rewarming rates of ~172 °C/min for 1 L and ~88 °C/min for 2 L, and temperature differences <5 °C.

    “Using nanowarming with iron-oxide nanoparticles and a newly developed 120 kW RF coil, uniform rewarming was achieved in up to 2 L volumes of M22 at ~88 °C/min.”
    • Also stated in: § Liter scale nanowarming · plain
      “Samples were rewarmed to 0°C within ~1 min for 1 L and ~2 min for 2 L at rates of ~172 °C/min and ~88 °C/min, respectively (Fig. 7C).”
    • Also stated in: § Liter scale nanowarming · plain
      “In all cases, the measured temperature differences across the cryobag volume were negligible (~<5°C) (Fig. 7D).”
    Quote in the paperSubstantial claim
  • It may state two separate claims as one.

    Findingown data

    Effective cryobag sealing was beneficial in preventing open-surface ice formation and reducing the size of the system (LC).

    “Effective cryobag sealing was beneficial in preventing open-surface ice formation and reducing the size of the system (LC).”
    Quote in the paperSubstantial claim
  • It may state two separate claims as one.

    Findingown data

    Cooling rates decreased and temperature differences increased with increasing sample volume.

    “As before, the cooling rates decreased, and the temperature differences increased with increasing sample volume.”
    Quote in the paperSubstantial claim
  • It may state two separate claims as one.

    Findingown data

    μCT confirmed successful vitrification in M22 and 40%EG + 0.6 M sucrose but ice formation in VS55 at 0.5 L.

    “We further confirmed our visual findings using µCT, which showed successful vitrification in M22 and 40%EG + 0.6Msucrose but ice formation in VS55 at 0.5 L volumes (Fig. S13).”
    Quote in the paperSubstantial claim
  • The quote only partly states this claim.

    Findingown data

    Nanowarming of 100 mgFe/mL EMG308 IONPs in VMP CPA in a 1 mL cryovial achieved warming rates of ~1500 °C/min.

    “We achieved warming rates at ~1500 °C/min (Fig. S22).”
    • Also stated in: § Liter scale nanowarming · plain
      “As a final proof of principle, we nanowarmed a higher concentration of IONP (100 mgFe/mL EMG308) using VMP as the CPA (closely related to M22) in a 1 mL cryovial30.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [30] Fahy, G. M. et al. Improved vitrification solutions based on the predictability of vitrification solution toxicity. Cryobiology 48, 22–35 (2004). source
  • It may state two separate claims as one.

    Findingown data

    The maximum field strength and frequency output were comparable between the 15 kW and 120 kW systems.

    “Importantly, the maximum field strength and frequency output were comparable between the 15 kW and 120 kW systems.”
    Quote in the paperNot a substantial claim
  • It may state two separate claims as one.

    Findingreasoning

    A small organ such as an ovary can convectively cool at ~15 °C/min, whereas the center of a liver is only expected to cool at ~0.6 °C/min.

    “For instance, a small organ such as an ovary can convectively cool at ~15 °C/min, whereas the center of a liver is only expected to cool at ~0.6 °C/min (these calculations assume the organ is vitrified alone without any surrounding CPA, but LC could be adjusted for individual container geometries).”
    Quote in the paperSubstantial claim
  • It may state two separate claims as one.

    Findingown data

    Vacuum sealing with removal of surrounding CPA solution led to ice on superficial surfaces of the liver, potentially due to cryobag surface nucleation, so having a layer of CPA around the liver in the bag proved beneficial for successful vitrification.

    “Vacuum sealing with the removal of surrounding CPA solution led to ice on superficial surfaces of the liver, potentially due to cryobag surface nucleation, so having a layer of CPA around the liver in the bag proved beneficial for successful vitrification.”
    Quote in the paperSubstantial claim
  • It may state two separate claims as one.

    Findingown data

    For a human kidney, perfused IONP concentration of ~10 mgFe/mL will provide a rewarming rate of ~40 °C/min, which is safely above the CWR of M22.

    “Fig. 9 shows that for a human kidney, perfused IONP concentration of ~10 mgFe/mL will provide a rewarming rate of ~40 °C/min, which is safely above the CWR of M22.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim. The paper’s conclusions may not depend on it.

    Findingnone given

    Achievable convective rewarming rates may be higher (~2 times) for small, less vascularized organs (e.g., ovaries and testes).

    “achievable convective rates may be higher (~2 times) for small, less vascularized organs (e.g., ovaries and testes).”
    Quote in the paperNot a substantial claim
  • It may state two separate claims as one.

    Findingreasoning

    For 3 L, the calculated characteristic length LC is ~2.2 cm and the expected cooling rate in the CRF is <0.8 °C/min.

    “for 3 L we can calculate LC ~ 2.2 cm and the expected CR in the CRF to be <0.8 °C/min.”
    Quote in the paperSubstantial claim
  • It may state two separate claims as one.

    Study design and conductown data

    A 120 kW RF coil with a 2.5 L uniform field region was designed, built, and characterized.

    “we worked with AMF LifeSystems, LLC. to design, build, and characterize a 120 kW RF coil with a 2.5 L uniform field region.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim. The paper’s conclusions may not depend on it.

    Study design and conductcitation

    SAR was calculated using the time rise method described elsewhere.

    “SAR was then calculated using the time rise method described elsewhere26,52 (see supplementary SAR section, Fig. S19).”
    Quote in the paperNot a substantial claim0 of 2 sources checked
    • cites [26] Etheridge, M. & Bischof, J. Optimizing magnetic nanoparticle based thermal therapies within the physical limits of heating. Ann. Biomed. Eng. 41, 78–88 (2013). source
    • cites [52] Ring, H. L. et al. The impact of data selection and fitting on SAR estimation for magnetic nanoparticle heating. Int. J. Hyperth. 37, 100–107 (2020). source
  • Probably not a substantial claim. The paper’s conclusions may not depend on it.

    Study design and conductown data

    RF coil performance was characterized by measuring the spatial distribution across the full range of magnetic field values.

    “Performance was characterized by measuring the spatial distribution across the full range of magnetic field values.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim. The paper’s conclusions may not depend on it.

    Interpretationcitation

    Additional ice nucleation may have occurred during storage of VS55 just below Tg.

    “suggesting additional ice nucleation may have occurred during storage.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim. The paper’s conclusions may not depend on it.

    Study design and conductnone given

    Temperature probes were pre-calibrated for any offset in the cryogenic temperature range.

    “The probes were pre-calibrated for any offset in the cryogenic temperature range.”
    Quote in the paperNot a substantial claim
  • It may state two separate claims as one.

    Interpretationown data

    Higher rewarming rates will be possible at higher IONP concentrations or with higher heating nanoparticles.

    “Higher rewarming rates will also be possible at higher IONP concentrations or with higher heating nanoparticles.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds.

    Study design and conductnone given

    The custom-made cooler can hold samples at cryogenic temperatures in a vitrified state (<Tg).

    “The custom-made cooler can hold samples at cryogenic temperatures in a vitrified state (<Tg).”
    Quote in the paperNot a substantial claim
  • It may state two separate claims as one.

    Interpretationown data

    Experimental test points showing success of M22, EG+Sucrose, and failure of VS55 at various LC validate the first-order approximation.

    “The experimental test points (x) showing success of M22, EG+Sucrose, and failure of VS55 at various LC (0.5, 1, 3 L volumes) are also plotted in B, validating the first-order approximation.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim. The paper’s conclusions may not depend on it.

    Premisecitation

    Other nanomaterials, such as nanowires/nanobars, have shown ultra-rapid nanowarming heating rates up to ~1000 °C/min at much lower nanoparticle concentrations in proof-of-principle cryovial (<1 mL) samples.

    “other nanomaterials, such as nanowires/nanobars, have also shown ultra-rapid nanowarming heating rates up to ~1000 °C/min at much lower nanoparticle concentrations in proof of principle cryovial (<1 mL) samples (e.g., Cobalt Nickel nanowires in VS55)45.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [45] Shore, D. et al. Nanowarming using Au-tipped Co35Fe65 ferromagnetic nanowires. Nanoscale 11, 14607–14615 (2019). source
  • It may state two separate claims as one.

    Premisecitation

    To achieve cryopreservation of human organs through vitrification, 0.5−1 L volumes are anticipated for hearts and kidneys, while human livers may require ≥3 L.

    “To achieve cryopreservation of human organs through vitrification, we anticipate needing 0.5−1 Liter volumes for hearts and kidneys, while human livers may require ≥3 L20.”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [20] Hall, C., Lueshen, E. & Linninger, A. A. Interspecies scaling in pharmacokinetics: a novel whole-body physiologically based modeling framework to discover drug biodistribution mechanisms in vivo. J. Pharm. Sci. 101, 1221–1241 (2012). source
  • It may state two separate claims as one.

    Premisecitation

    Even under conditions where vitrification upon cooling was successful, even faster rates are required upon rewarming, leading to failures at the rabbit kidney scale.

    “Even under conditions where vitrification upon cooling was successful, even faster rates are required upon rewarming, leading to failures (ice formation and/or cracking) at the rabbit kidney scale6.”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [6] Manuchehrabadi, N. et al. Improved tissue cryopreservation using inductive heating of magnetic nanoparticles. Sci. Transl. Med. 9, eaah4586 (2017). source
  • Probably not a substantial claim. The paper’s conclusions may not depend on it.

    Study design and conductown data

    Modeled and experimentally measured magnetic field distributions were used to compare spatial uniformity between the 15 kW and 120 kW RF coils.

    “We used modeled as well as experimentally measured magnetic field distribution to compare spatial uniformity between the previously characterized 15 kW6 and the new 120 kW RF coils (Fig. S16).”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [6] Manuchehrabadi, N. et al. Improved tissue cryopreservation using inductive heating of magnetic nanoparticles. Sci. Transl. Med. 9, eaah4586 (2017). source
  • Probably not a substantial claim. The paper’s conclusions may not depend on it.

    Study design and conductown data

    The colloidal stability of sIONPs and EMG308 in M22 was monitored by dynamic light scattering.

    “The colloidal stability of sIONPs and EMG308 in M22 was monitored by dynamic light scattering (DLS, see Fig. S1).”
    Quote in the paperNot a substantial claim
  • It may state two separate claims as one.

    Interpretationreasoning

    The minimum CPA concentration for vitrification at 3 L is ~62% w/w, slightly lower than M22 (~66% w/w including carrier solution).

    “Hence, the minimum CPA concentration for vitrification would be ~62% w/w, which is slightly lower than M22 (~66%w/w which includes carrier solution)”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim. The paper’s conclusions may not depend on it.

    Premisecitation

    Storage of VS55 for 6 months just below Tg increased CWR from 50 to ~100 °C/min.

    “storage of VS55 for 6 months just below Tg increased CWR from 50 to ~100 °C/min40”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [40] Mehl, P. M. Nucleation and crystal growth in a vitrification solution tested for organ cryopreservation by vitrification. Cryobiology, 30. (1993) source
  • It may state two separate claims as one.

    Premisecitation

    VS83 (83% w/w CPA) has lower CCR and can be more easily vitrified than the CPAs chosen here.

    “Higher concentrations of CPAs such as VS83 (83% w/w CPA) have even lower CCR and can be more easily vitrified”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [35] Han, Z. et al. Model-guided design and optimization of CPA perfusion protocols for whole organ cryopreservation. Ann. Biomed. Eng. 51, 2216–2228 (2023). source
  • Probably not a substantial claim.

    Study design and conductreasoning

    The recommended protocols were designed so that the temperature difference within the glassy state is less than 20 °C to avoid fracture.

    “Further, the ∆T within the glassy state was designed to be less than 20 °C, to avoid fracture.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim.

    Premisecitation

    A temperature difference <20 °C in the brittle glassy phase is an allowable limit.

    “After annealing, the system was cooled slowly (<1 °C/min) to −150 °C for storage to minimize thermal stress, keeping the temperature difference (<20 °C) in the brittle glassy phase21,25.”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites [21] Gangwar, L. et al. Perspective: A Guide to Successful ml to L Scale Vitrification and Rewarming. CryoLetters 43, 303–315 (2022). source
    • cites [25] Steif, P. S., Palastro, M. C. & Rabin, Y. The effect of temperature gradients on stress development during cryopreservation via vitrification. Cell Preserv. Technol. 5, 104–115 (2007). source
  • Probably not a substantial claim. The paper’s conclusions may not depend on it.

    Study design and conductnone given

    The University of Minnesota's IACUC approved this study.

    “The University of Minnesota’s Institutional Animal Care and Use Committee (IACUC) approved this study.”
    • Also stated in: § Ethical declaration · plain
      “The Institutional IACUC committee from the University of Minnesota (protocol #2111A39564) approved all animal studies.”
    Quote in the paperNot a substantial claim
  • It may state two separate claims as one.

    Premisecitation

    For long-term storage of human organ-scale vitrified samples, physical aging of the glass can elevate Tg, decrease Td, and increase heat release at the glass transition during rewarming.

    “For long-term storage (days to months to years) of human organ-scale vitrified samples, physical aging of the glass can also elevate Tg, decrease Td (devitrification temperature), and increase heat release at the glass transition during rewarming from the vitrified state41,42.”
    Quote in the paperNot a substantial claim0 of 2 sources checked
    • cites [41] Chang, Z. H. & Baust, J. G. Physical aging of glassy state: DSC study of vitrified glycerol systems. Cryobiology 28, 87–95 (1991). source
    • cites [42] Struik, L. C. E. Physical aging in plastics and other glassy materials. Polym. Eng. Sci. 17, 165–173 (1977). source
  • It may state two separate claims as one.

    Premisecitation

    There are currently no volumetric means of cooling human organs, so convective cooling will be directly impacted by the size of the system, with the cooling rate at the center decreasing as size increases.

    “There are currently no volumetric means of cooling human organs, so convective cooling will be directly impacted by the size of the system, with the cooling rate at the center of the sample decreasing as the size of the system increases21.”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [21] Gangwar, L. et al. Perspective: A Guide to Successful ml to L Scale Vitrification and Rewarming. CryoLetters 43, 303–315 (2022). source
  • Probably not a substantial claim.

    Study design and conductnone given

    The recommended annealing and glassy region cooling rate protocols were designed to be faster than the CCR of the noted CPAs between the melt and glass transitions.

    “These protocols were designed to be faster than the CCR of the noted CPAs between the melt and glass transitions.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim.

    Study design and conductnone given

    A total of ≥3 replicates were conducted for all cooling, nanowarming, and SAR experiments.

    “A total of ≥3 replicates are conducted for all the cooling, nanowarming, and SAR experiments.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim.

    Study design and conductown data

    Microcomputed tomography (μCT) was used to verify physical vitrification.

    “Microcomputed tomography (µCT) was used to verify physical vitrification (Fig. S13, S15).”
    Quote in the paperSubstantial claim
  • It may state two separate claims as one.

    Interpretationcitation

    This may lead to insufficient cooling rates and/or physical fractures/cracking due to thermal gradients in the vitrified state if a proper cooling protocol is not employed.

    “This may lead to insufficient cooling rates and/or physical fractures/cracking due to thermal gradients in the vitrified state22 if a proper cooling protocol is not employed.”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [22] Rabin, Y. et al. Fracture formation in vitrified thin films of cryoprotectants. Cryobiology 53, 75–95 (2006). source
  • Probably not a substantial claim. The paper’s conclusions may not depend on it.

    Interpretationreasoning

    M22 might be more prone to fractures from thermal stress because it has a greater thermal expansion coefficient and polymers that may be more thermally expansive.

    “which could mean that M22 (which has polymers that may be more thermally expansive44) might be more prone to fractures from thermal stress.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [44] Holliday, L. & Robinson, J. The thermal expansion of composites based on polymers. J. Mater. Sci. 8, 301–311 (1973). source
    • Rests on an assumption: CPA constituents (polymers, sugars, salts, etc.) can impact stability in the brittle (glassy) state.
  • Probably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds.

    Interpretationreasoning

    A lack of uniformity during convective rewarming may still lead to cracking in small, less vascularized organs.

    “However, a lack of uniformity during convective rewarming may still lead to cracking in these cases.”
    Quote in the paperNot a substantial claim
    • Rests on an assumption: Cracking is a major mode of physical injury during organ vitrification.
  • Probably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds.

    Interpretationreasoning

    Nanowires/nanobars may be limited to external heating due to their aspect ratio, size, and biocompatibility concerns.

    “Still, these may be limited to external heating due to their aspect ratio, size, and concerns regarding biocompatibility.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim. The paper’s conclusions may not depend on it. It may state two separate claims as one.

    Study design and conductnone given

    Replicates were performed on different days with distinct samples for livers and the same samples on different days for CPA experiments.

    “Replicates were performed on different days with distinct samples for livers and the same samples on different days for CPA experiments.”
    Quote in the paperNot a substantial claim
41 of 41
  • The paper relies on this without support.

    Neither successful vitrification nor rewarming has been demonstrated in the literature at human organ scales (0.5–3 L).

    “However, neither successful vitrification nor rewarming has been demonstrated in the literature at these scales.”
  • The paper relies on this without support.

    Capillary spacing is relatively conserved across organs and tissues, and uniformity and heating rate depend primarily on IONP concentration, magnetic field strength distribution, and frequency.

    “Since capillary spacing is relatively conserved across organs and tissues, uniformity and heating rate depend primarily on the concentration of IONPs, distribution of the magnetic field strength, and frequency.”
  • The authors state this as an assumption.

    The thermal properties of M22 are a reasonable approximation for the other CPAs (VS55 and 40%EG + 0.6 M sucrose).

    “Limited data on CPA thermal properties are available, hence we assume them to be that of M22 (listed in Table S2)23, which should be a reasonable approximation for each of the other CPAs.”
  • The paper relies on this without support.

    Convection within the CPA itself is neglected due to the high viscosity of CPAs at subzero temperatures.

    “Convection within the CPA itself is neglected due to the high viscosity of CPAs at subzero temperatures.”
  • The paper relies on this without support.

    The critical cooling rate (CCR) of M22 is ~0.1 °C/min.

    “Mean cooling rates are greater than the CCR of M22 (~0.1 °C/min).”
  • The paper relies on this without support.

    The critical cooling rate (CCR) of VS55 is ~2.5 °C/min.

    “This was expected as the achieved cooling rate for these three volumes (0.5 L~1.4 °C/min, 1 L~1 °C/min, 3 L~0.5 °C/min) were lower than the CCR of VS55 (~2.5 °C/min).”
  • The paper relies on this without support.

    The critical cooling rate (CCR) of 40%EG + 0.6 M sucrose is ~1 °C/min.

    “Modeling predicted the center cooling rate of the liver as ~4 °C/min, which exceeds the CCR (~1 °C/min) of 40%EG + 0.6Msucrose, which further supports vitrification (see Fig. S6).”
  • The paper relies on this without support.

    The critical warming rate (CWR) of M22 is ~0.4 °C/min.

    “Average rewarming rates are greater than the CWR of M22 (~0.4 °C/min).”
  • The authors state this as an assumption.

    IONP distributions are practically uniform through vascular perfusion to the capillary beds.

    “As noted earlier, uniformity in rewarming will depend on the uniformity of the applied field, assuming practically uniform IONP distributions (i.e., through vascular perfusion to the capillary beds).”
  • The paper relies on this without support.

    Heat rapidly diffuses across intercapillary distances given the timescales of rewarming.

    “as the heat rapidly diffuses across intercapillary distances.”
  • The authors state this as an assumption.

    Organs can be approximated as ellipsoidal shapes for LC calculation.

    “LC is calculated for various organs assuming ellipsoidal shape, and minimum cooing rate occurs at the center of geometry.”
  • The authors state this as an assumption.

    The minimum cooling rate occurs at the center of the geometry.

    “LC is calculated for various organs assuming ellipsoidal shape, and minimum cooing rate occurs at the center of geometry.”
  • The paper relies on this without support.

    Cracking is a major mode of physical injury during organ vitrification.

    “The other major mode of physical injury during organ vitrification is cracking.”
  • The paper relies on this without support.

    CPA constituents (polymers, sugars, salts, etc.) can impact stability in the brittle (glassy) state.

    “Further, CPA constituents (polymers, sugars, salts, etc.) can also impact stability in the brittle (i.e., glassy) state.”
  • The authors state this as an assumption.

    CPA would fully equilibrate in tissue.

    “we assumed that CPA would fully equilibrate in tissue”
15 of 15

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

  • CPA replicates described as both distinct and reused samples

    Minor

    The Fig. 7 legend describes the M22 nanowarming experiments as using distinct samples, whereas the data-analysis section says CPA experiments reused the same samples on different days.

1 of 1

Citations

Cites

Flagged first, then by citations

1 of the 53 references couldn’t be matched to a known paper.

Research works printed but not linked: 1

  1. Incropera, F. P., et al., Fundamentals of heat and mass transfer. Vol. 6. Wiley New York. (1996)

Cited by

Sorted by citations

Metadata

Authors
Gangwar, L., Han, Z., Scheithauer, C., Namsrai, B.-E., Kantesaria, S., Goldstein, R., Etheridge, M. L., Finger, E. B., & Bischof, J. C.
Affiliations
University of Minnesota (US)
Corresponding author
  • Finger, Erik B.
  • Bischof, John C.
Venue
Nature Communications
Published
2025-09-26
Volume
16
Issue
1
Pages
8511-8511
ISSN
2041-1723 (ISSN-L)
OpenAlex
W4414543818
Cited by
26
References
53
Citations by year
2026: 20 · 2025: 5
FWCI
17.51
Type
journal article
Language
en
Open access
Locations
  • Nature Communications (publishedVersion, cc-by-nc-nd)
  • bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed Central (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • U.S. Department of Health & Human Services | National Institutes of Health (R01DK117425, R01HL135046, R01DK132211)
  • National Science Foundation (EEC 1941543)
Topics
  • Health Sciences › Medicine › Surgery › Organ Transplantation Techniques and Outcomes
  • Physical Sciences › Chemistry › Physical and Theoretical Chemistry › nanoparticles nucleation surface interactions
  • Health Sciences › Medicine › Surgery › Transplantation: Methods and Outcomes
Keywords
organ cryopreservation, organ banking, cryoprotectants, nanowarming, RF heating, convective cooling, critical cooling rate, porcine liver, iron oxide nanoparticles, M22, organ perfusion

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review