The DOI matches its Crossref record.
Pulse method for simultaneous measurement of electric thermopower and heat conductivity at low temperatures
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the pulsed power technique, a small temperature gradient ΔT = Th - Tc (usually ~0.3 K) is created between the heat source and the heat sink, which can be measured by a calibrated Au-Fe chromel thermocouple.
“A small temperature gradient ∆𝑇 = 𝑇 ℎ -𝑇 𝑐 (usually ~0.3 K) is created between the heat source and the heat sink, which can be measured by a calibrated Au-Fe chromel thermocouple [38].”
From Measurement Techniques for Thermal Conductivity and Interfacial Thermal Conductance of Bulk and Thin Film Materials (2016) · cites this paper as [38]
The measurement uncertainty reported by Maldonado for the pulsed power technique is less than 3%.
“The measurement uncertainty reported by Maldonado is less than 3% [38].”
From Measurement Techniques for Thermal Conductivity and Interfacial Thermal Conductance of Bulk and Thin Film Materials (2016) · cites this paper as [38]
The pulsed power technique was first introduced by Maldonado to measure both thermal conductivity and thermoelectric power.
“Pulsed power technique was first introduced by Maldonado to measure both thermal conductivity and thermoelectric power [38].”
From Measurement Techniques for Thermal Conductivity and Interfacial Thermal Conductance of Bulk and Thin Film Materials (2016) · cites this paper as [38]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 7
- Hohn, 1992, Physica C, 191, 354, 10.1016/0921-4534(92)90930-B · DOI
- Yu, 1988, Phys Rev B, 37, 7963, 10.1103/PhysRevB.37.7963 · DOI
- Roberts, 1977, Phil Mag, 36, 91, 10.1080/00318087708244450 · DOI
- Roberts, 1981, Phil Mag, 43, 1125, 10.1080/01418638108222579 · DOI
- Osborne, 1967, Rev Sci Instrum, 38, 159, 10.1063/1.1771348 · DOI
- Cude, 1971, Cryogenics, 11, 394, 10.1016/0011-2275(71)90039-7 · DOI
- Jayasuriya, 1982, J Phys E: Sci Instrum, 15, 885, 10.1088/0022-3735/15/9/005 · DOI
Cited by
Sorted by citations
Zhao, D., Qian, X., Gu, X., Jajja, S. A., & Yang, R. (2016) · Journal of Electronic Packaging · doi:10.1115/1.4034605 · Cited by 559
Low Temperature Thermal Properties of Nanodiamond Ceramics
Szewczyk, D., & Ramos, M. A. (2022) · Crystals · doi:10.3390/cryst12121774 · Cited by 5
Metadata
- Authors
- Maldonado, O.
- Venue
- Cryogenics
- Publisher
- Elsevier BV
- Published
- 1992-01
- Volume
- 32
- Issue
- 10
- Pages
- 908-912
- ISSN
- 0011-2275
- Cited by
- 99
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review