The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Tendon reflex variability and method of stimulation
Abstract
Human tendon reflexes show large fluctuations, even when accurate mechanical instruments are used for stimulation. To examine the contribution of stimulus factors to reflex variability two methods of stimulation were compared in healthy subjects. One method consisted of a normal hand-held reflex hammer, with a transducer to measure stimulus intensity. The results with this hammer, both after maximal stimuli and after stimuli over a wide range of intensities, showed a similar variability of reflexes as with a more accurate instrumental stimulator. In previous studies in human subjects an equal or larger variability of reflexes was found. It is concluded that for many applications a simple hand-held reflex hammer gives equally reliable results as more complicated instrumental stimulators.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A custom-built pneumatic tendon tapper (Figure 1A) was used to keep the amplitude, pressure, and location of the taps constant due to a demonstrated relationship between stimulus strength and reflex amplitude [22,23].”
In the citing paper
“However, concerns regarding its consistency have been raised due to the fact that it shows wide variation among human subjects4, 5).”
From Clinical availability of the deep tendon reflex test using a novel apparatus in healthy subjects (2015) · cites this paper as [4]
In the citing paper
“There was also evidence suggesting that tendon taps produced by the instrumented hammer were unpleasant to the subjects [20].”
From The Validity and Reliability of Motion Analysis in Patellar Tendon Reflex Assessment (2013) · cites this paper as [20]
In the citing paper
“According to a study on the effects of reflex stimulus to reflex responses by Stam and Tan (1987), reflex response could be affected by various factors, such as tapping force, direction and location of the impact.”
From The Validity and Reliability of Motion Analysis in Patellar Tendon Reflex Assessment (2013) · cites this paper as Stam and Tan (1987)
In the citing paper
“The variation of patellar tendon reflex in healthy subjects remained high as found in earlier studies.”
From Motion Analysis of Normal Patellar Tendon Reflex (2013) · cites this paper as [6]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The afferent volleys responsible for spinal proprioceptive reflexes in man
Burke, D., Gandevia, S. C., & McKeon, B. (1983) · The Journal of Physiology · doi:10.1113/jphysiol.1983.sp014732 · Cited by 274
Rudomin, P., & Dutton, H. (1969) · Journal of Neurophysiology · doi:10.1152/jn.1969.32.2.140 · Cited by 80
Lombard, W. P. (1887) · The American Journal of Psychology · doi:10.2307/1411231 · Cited by 63
Dietrichson, P., & Sörbye, R. (1971) · Acta Neurologica Scandinavica · doi:10.1111/j.1600-0404.1971.tb07461.x · Cited by 51
Hunt, C. C. (1955) · The Journal of General Physiology · doi:10.1085/jgp.38.6.801 · Cited by 34
Dimitrijevic, M. R., & Nathan, P. W. (1973) · Brain · doi:10.1093/brain/96.2.337 · Cited by 27
A simple measurement hammer for quantitative reflex studies
Stam, J., & van Leeuwen, J. R. (1984) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(84)90114-7 · Cited by 14
Self-citationPHYSIOLOGICAL STUDIES ON THE PATELLAR REFLEX
PEREIRA, J. R. (1925) · Brain · doi:10.1093/brain/48.2.255 · Cited by 5
Mechanical impulse system for myotatic reflex investigation
Vermarien, H., Maes, L., & Vereecke, F. (1984) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447707 · Cited by 3
An apparatus for isometric study of the human knee jerk.
Davis, C., & Beale, D. K. (1970) · Journal of Applied Physiology · doi:10.1152/jappl.1970.28.5.705 · Cited by 3
Research works printed but not linked: 2
- Simons, 1972, Quantitative variations in the force of quadriceps responses to serial patellar taps in normal man, Amer. J. phys. Med., 51, 240
- Simons, 1971, Automated system for the measurement of reflex responses to patellar taps in man, Amer. J. phys. Med., 50, 72
Cited by
Voerman, G., Gregorič, M., & Hermens, H. (2005) · Disability and Rehabilitation · doi:10.1080/09638280400014600 · Cited by 201
“Other studies indicated a considerable inter-individual and intraindividual variation in T-value amplitudes, making comparison between subject populations hard [222,234,253,254].”
BackgroundParaspinal muscle reflex dynamics
Granata, K. P., Slota, G. P., & Bennett, B. C. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00249-5 · Cited by 124
Schmit, B. D., Dewald, J. P. A., & Rymer, W. Z. (2000) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(00)90070-4 · Cited by 124
Sensorimotor Manipulations of the Balance Control Loop–Beyond Imposed External Perturbations
Rasman, B. G., Forbes, P. A., Tisserand, R., & Blouin, J. (2018) · Frontiers in Neurology · doi:10.3389/fneur.2018.00899 · Cited by 107
Reliability of Biomechanical Spasticity Measurements at the Elbow of People Poststroke
Starsky, A. J., Sangani, S. G., McGuire, J. R., Logan, B. R., & Schmit, B. D. (2005) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2005.03.015 · Cited by 89
Metadata
- Authors
- Stam, J., & Tan, K. M.
- Affiliations
- Amsterdam UMC Location University of Amsterdam (NL)
- Corresponding author
- Stam, J.
- ORCID
- Stam, J.
- Venue
- Electroencephalography and Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 1987-11
- Volume
- 67
- Issue
- 5
- Pages
- 463-467
- ISSN
- 0013-4694 (ISSN-L)
- OpenAlex
- W1973958968
- Cited by
- 64
- References
- 11
- Citations by year
- 2026: 1 · 2024: 1 · 2023: 1 · 2021: 1 · 2020: 4 · 2019: 1 · 2018: 1 · 2017: 1 · 2016: 2 · 2015: 3 · 2013: 6 · 2012: 1
- FWCI
- 1.41
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Electroencephalography and Clinical Neurophysiology (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Peripheral Nerve Disorders
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Keywords
- deep tendon reflexes, stimulus intensity, mechanical stimulation
- MeSH terms
- Adult, Humans, Physical Stimulation, Reflex, Stretch
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tendon reflex variability and method of stimulation. https://app.cochat.ai/papers/10.1016/0013-4694(87)90010-1
- The paper
- Stam, J., & Tan, K. M. (1987). Tendon reflex variability and method of stimulation. Electroencephalography and Clinical Neurophysiology. https://doi.org/10.1016/0013-4694(87)90010-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.