Student or educator? Sign up with your school email and get 6 months of Pro free.

The DOI matches its Crossref record; 25 of the 26 references it cites were found in a registry or an index; none of the 20 sources its claims cite is checked for support yet.

The Validity and Reliability of Motion Analysis in Patellar Tendon Reflex Assessment

Open access
Tham, Lai Kuan, Abu Osman, Noor Azuan, Wan Abas, Wan Abu Bakar, Lim, Kheng Seang·2013·PLoS ONE

Abstract

BACKGROUND: The deep tendon reflex assessments that are essential to the accurate diagnosis of neurological or neuromuscular disorders are conducted subjectively in clinical neurology. Our aim was to assess deep tendon reflexes objectively with a new reflex quantification method. METHODOLOGY/PRINCIPAL FINDINGS: The present study used a motion analysis technique to collect quantitative measurements for both the input and output of normal patellar tendon reflex. Reflex responses were measured as knee angles. The patellar tendon reflexes of 100 healthy subjects were examined using 6 levels of tendon taps, where all the assessments were captured using motion capture system. A linear relationship was found between the experimental maximum tapping velocity and tapping angle (coefficient of determination = 0.989), which was consistent with the theoretical values. Tapping velocities were predictable according to tapping angles. The findings proved the reproducibility of tapping method in producing consistent input. The reflex amplitude was consistent between two randomly assigned groups, and linearly proportionate to the tapping velocity. CONCLUSIONS/SIGNIFICANCE: The findings on reflex amplitude indicate that motion analysis is a valid and reliable method of assessing and measuring deep tendon reflexes.

Overview

CoChat Summary

TL;DR

The study assessed whether motion analysis can objectively quantify patellar tendon reflex input and output in 100 healthy adults. It reports that tapping angle predicts maximum tapping velocity and that reflex amplitude is consistent across random groups and linearly related to tapping velocity, supporting validity and reliability.

Key findings

  • A linear relationship was found between experimental maximum tapping velocity and tapping angle, with a coefficient of determination of 0.989; one-sample t-tests found no significant differences between experimental and theoretical maximum velocity at all tapping angles.
  • Reflex amplitude increased with tapping angle, was significantly lower for 15°, 30°, and 45°, and showed no significant differences for 60° vs 75° and 75° vs 90°; the authors suggest 45° or 60° as the optimum tapping angle.
  • Reflex amplitude was linearly related to tapping input by y = 4.9x–1.8, with a Pearson correlation coefficient of 0.501 (P<0.001).
  • Comparisons of reflex amplitude between two random groups of 50 subjects each found no significant difference for all tapping angles.

Methods

  • One hundred healthy subjects (50 males, 50 females) aged 21–32 years with no history or recent record of neurological disorders were examined; subjects with neurological disorders that might exhibit abnormal reflex responses were excluded.
  • Patellar tendon reflexes were captured with Vicon Nexus 1.6 at 50 Hz using 16 lower-body reflective markers and a Queen Square reflex hammer with 3 markers and a protractor; subjects sat upright with legs dangling and body movements were not limited.
  • Each side was tapped at 15°, 30°, 45°, 60°, 75°, and 90°, with 5 taps per angle and the best response documented; analyses included one-sample t-tests, linear regression, student t-tests, correlation, and paired t-tests, with P<0.05 considered significant.

Limitations

  • The paper states that patellar tendons were tapped sequentially from 15° to 90°, not in random order, which might contribute to the plateau of reflex response at higher angles; random reflex input is suggested for future work.
  • The paper states that the marker-and-camera setup limits usefulness in daily clinical practice, though it can be set up in a clinic or ward for clinical study.
  • Evident from the text: the sample was restricted to healthy adults aged 21–32 years without neurological disorders, so findings may not generalize to patients with neurological or neuromuscular disorders or to other age groups.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0055702

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Representative knee angle of a patellar tendon reflex test. Time 0 is the time the reflex hammer struck the patellar tendon. Reflex amplitude is measured as the offset of knee angle from the original position.
Figure 1 Representative knee angle of a patellar tendon reflex test. Time 0 is the time the reflex hammer struck the patellar tendon. Reflex amplitude is measured as the offset of knee angle from the original position.CC BY · PubMed Central
Figure 2 Representative relationship between the tapping angle and the experimental maximum tapping velocity.
Figure 2 Representative relationship between the tapping angle and the experimental maximum tapping velocity.CC BY · PubMed Central
Figure 3 Mean values of patellar tendon reflex amplitudes according to tapping angle (± standard error). The reflex amplitude increased gradually with the increment of tapping angle. * denotes statistical significance difference compared to tapping angle of 15°. # denotes statistical significance difference compared to tapping angle of 30°. $ denotes statistical significance difference compared to tapping angle of 45°. ¤ denotes statistical significance difference compared to tapping angle of 60°. ¢ denotes statistical significance difference compared to tapping angle of 75°. ¥ denotes statistical significance difference compared to tapping angle of 90°. Symbols (¤, ¥) in bold indicates statistical significance difference at P<0.01, symbols not in bold indicates statistical significance difference at P<0.001.
Figure 3 Mean values of patellar tendon reflex amplitudes according to tapping angle (± standard error). The reflex amplitude increased gradually with the increment of tapping angle. * denotes statistical significance difference compared to tapping angle of 15°. # denotes statistical significance difference compared to tapping angle of 30°. $ denotes statistical significance difference compared to tapping angle of 45°. ¤ denotes statistical significance difference compared to tapping angle of 60°. ¢ denotes statistical significance difference compared to tapping angle of 75°. ¥ denotes statistical significance difference compared to tapping angle of 90°. Symbols (¤, ¥) in bold indicates statistical significance difference at P<0.01, symbols not in bold indicates statistical significance difference at P<0.001.CC BY · PubMed Central
Figure 4 Reflex amplitude of random groups in mean (± standard error) according to tapping angle.
Figure 4 Reflex amplitude of random groups in mean (± standard error) according to tapping angle.CC BY · PubMed Central

Verification

Claims the paper makes

0 Valid · 0 Not valid · 15 Not checked · 28 Own results and interpretations

21 more claims

Create a free account to see all 43 claims and every source verdict.

See all claims — free account
  • It may state two separate claims as one. 11
  • Probably not a substantial claim. 12

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

10 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Show all 26 references

Cited by

See all 33

Metadata

Authors
Tham, L. K., Abu Osman, N. A., Wan Abas, W. A. B., & Lim, K. S.
Affiliations
University of Malaya (MY)
Corresponding author
Tham, Lai Kuan
Venue
PLoS ONE
Published
2013-02-07
Volume
8
Issue
2
Pages
e55702
ISSN
1932-6203 (ISSN-L)
OpenAlex
W1968567484
Cited by
32
References
26
Citations by year
2026: 2 · 2025: 1 · 2024: 4 · 2023: 1 · 2021: 6 · 2020: 2 · 2019: 1 · 2018: 1 · 2017: 1 · 2016: 2 · 2015: 6 · 2014: 1 · 2013: 4
FWCI
2.37
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • The University of Malaya Research Repository (University of Malaya) (acceptedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
  • Health Sciences › Medicine › Clinical Neurology › Peripheral Nerve Disorders
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
patellar reflex, deep tendon reflexes, motion analysis, knee joint angle, reflex amplitude, neuromuscular disorders, reproducibility
MeSH terms
Humans, Motion, Reference Values, Patellar Ligament

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-09-30, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-09-30 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Validity and Reliability of Motion Analysis in Patellar Tendon Reflex Assessment. https://app.cochat.ai/papers/10.1371/journal.pone.0055702
The paper
Tham, L. K., Abu Osman, N. A., Wan Abas, W. A. B., & Lim, K. S. (2013). The Validity and Reliability of Motion Analysis in Patellar Tendon Reflex Assessment. PLoS ONE. https://doi.org/10.1371/journal.pone.0055702

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.