The DOI matches its Crossref record; 25 of the 26 references it cites were found in a registry or an index; none of the 20 sources its claims cite is checked for support yet.
The Validity and Reliability of Motion Analysis in Patellar Tendon Reflex Assessment
Open accessAbstract
BACKGROUND: The deep tendon reflex assessments that are essential to the accurate diagnosis of neurological or neuromuscular disorders are conducted subjectively in clinical neurology. Our aim was to assess deep tendon reflexes objectively with a new reflex quantification method. METHODOLOGY/PRINCIPAL FINDINGS: The present study used a motion analysis technique to collect quantitative measurements for both the input and output of normal patellar tendon reflex. Reflex responses were measured as knee angles. The patellar tendon reflexes of 100 healthy subjects were examined using 6 levels of tendon taps, where all the assessments were captured using motion capture system. A linear relationship was found between the experimental maximum tapping velocity and tapping angle (coefficient of determination = 0.989), which was consistent with the theoretical values. Tapping velocities were predictable according to tapping angles. The findings proved the reproducibility of tapping method in producing consistent input. The reflex amplitude was consistent between two randomly assigned groups, and linearly proportionate to the tapping velocity. CONCLUSIONS/SIGNIFICANCE: The findings on reflex amplitude indicate that motion analysis is a valid and reliable method of assessing and measuring deep tendon reflexes.
Overview
CoChat Summary
TL;DR
The study assessed whether motion analysis can objectively quantify patellar tendon reflex input and output in 100 healthy adults. It reports that tapping angle predicts maximum tapping velocity and that reflex amplitude is consistent across random groups and linearly related to tapping velocity, supporting validity and reliability.
Key findings
- A linear relationship was found between experimental maximum tapping velocity and tapping angle, with a coefficient of determination of 0.989; one-sample t-tests found no significant differences between experimental and theoretical maximum velocity at all tapping angles.
- Reflex amplitude increased with tapping angle, was significantly lower for 15°, 30°, and 45°, and showed no significant differences for 60° vs 75° and 75° vs 90°; the authors suggest 45° or 60° as the optimum tapping angle.
- Reflex amplitude was linearly related to tapping input by y = 4.9x–1.8, with a Pearson correlation coefficient of 0.501 (P<0.001).
- Comparisons of reflex amplitude between two random groups of 50 subjects each found no significant difference for all tapping angles.
Methods
- One hundred healthy subjects (50 males, 50 females) aged 21–32 years with no history or recent record of neurological disorders were examined; subjects with neurological disorders that might exhibit abnormal reflex responses were excluded.
- Patellar tendon reflexes were captured with Vicon Nexus 1.6 at 50 Hz using 16 lower-body reflective markers and a Queen Square reflex hammer with 3 markers and a protractor; subjects sat upright with legs dangling and body movements were not limited.
- Each side was tapped at 15°, 30°, 45°, 60°, 75°, and 90°, with 5 taps per angle and the best response documented; analyses included one-sample t-tests, linear regression, student t-tests, correlation, and paired t-tests, with P<0.05 considered significant.
Limitations
- The paper states that patellar tendons were tapped sequentially from 15° to 90°, not in random order, which might contribute to the plateau of reflex response at higher angles; random reflex input is suggested for future work.
- The paper states that the marker-and-camera setup limits usefulness in daily clinical practice, though it can be set up in a clinic or ward for clinical study.
- Evident from the text: the sample was restricted to healthy adults aged 21–32 years without neurological disorders, so findings may not generalize to patients with neurological or neuromuscular disorders or to other age groups.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
0 Valid · 0 Not valid · 15 Not checked · 28 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The correlation between the tapping input and reflex amplitude was strong (Pearson’s correlation coefficient was 0.501, P value <0.001).”
§ The Validity and Reliability of Motion Analysis in Patellar Tendon Reflex Assessment > Results
boostedstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on 2 assumptions not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“and linearly proportionate to the tapping velocity.”
- Also stated in: § Results · plain
“The reflex amplitude was linearly related to the tapping input with an equation of y = 4.9x–1.8”
§ The Validity and Reliability of Motion Analysis in Patellar Tendon Reflex Assessment > Abstract > Methodology/Principal Findings
plainstates an associationn = 100- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on 2 assumptions not shown here.
- Also stated in: § Results · plain
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“In general, reflex amplitude increased as the tapping angle increased.”
§ The Validity and Reliability of Motion Analysis in Patellar Tendon Reflex Assessment > Results
hedgedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on 3 assumptions not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“A linear relationship was found between the experimental maximum tapping velocity and tapping angle (coefficient of determination = 0.989)”
- Also stated in: § Results · boosted
“A linear relationship between the tapping angle and the experimental maximum tapping velocity is demonstrated in Figure 2, with coefficient of determination close to 1 (r 2 value of 0.989).”
§ The Validity and Reliability of Motion Analysis in Patellar Tendon Reflex Assessment > Abstract > Methodology/Principal Findings
boostedstates an associationn = 100- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § Results · boosted
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The one sample t-test found no significant differences between experimental and theoretical maximum velocity at all tapping angles.”
§ The Validity and Reliability of Motion Analysis in Patellar Tendon Reflex Assessment > Results
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
21 more claims
Create a free account to see all 43 claims and every source verdict.
- It may state two separate claims as one. 11
- Probably not a substantial claim. 12
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“In contrast, Tham et al.8) reported that an appropriate tendon reflex was only induced if a tapping angle of > 60° was used.”
From Clinical availability of the deep tendon reflex test using a novel apparatus in healthy subjects (2015) · cites this paper as [8]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In more recent studies, quantitative trials of the DTR test have been carried out using motion analysis, which examines angular velocity and acceleration of the relative joints8, 11).”
From Clinical availability of the deep tendon reflex test using a novel apparatus in healthy subjects (2015) · cites this paper as [8]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Consistent with our study, the authors found that the amplitude of the response increased linearly in accordance with increased percussion angle, and a concomitant motion analysis confirmed the high reliability of the DTR data8).”
From Clinical availability of the deep tendon reflex test using a novel apparatus in healthy subjects (2015) · cites this paper as [8]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Moreover, the previous studies lacked accurate and standardized yet convenient methods to quantify the reflex response for large-sized populations [10], which is possible with the motion analysis technique [22].”
From Influence of Age on Patellar Tendon Reflex Response (2013) · cites this paper as [22]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Many previous studies have sought to identify quantitative and objective measures for the DTR test6,7,8).”
From Clinical availability of the deep tendon reflex test using a novel apparatus in healthy subjects (2015) · cites this paper as [8]
10 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216 · cited 1×
“A total of 16 reflective markers (14 mm diameter) were attached to the lower body of the subjects following the Plug-in-Gait Marker Placement [24].”
A gait analysis data collection and reduction technique
Davis, R. B., Õunpuu, S., Tyburski, D., & Gage, J. R. (1991) · Human Movement Science · doi:10.1016/0167-9457(91)90046-z · Cited by 3,086 · cited 1×
“Motion capture systems are commonly used to analyze the joint kinematics and kinetics of human locomotion [22].”
Manschot, S., van Passel, L., Buskens, E., Algra, A., & van Gijn, J. (1998) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.64.2.253 · Cited by 86 · cited 1×
“Clinical evaluation on tendon reflex is qualitative and subjective, leading to great variation in the assessments [10].”
Normal values of patellar and ankle tendon reflex latencies
Frijns, C. J. M., Laman, D. M., van Duijn, M. A. J., & van Duijn, H. (1997) · Clinical Neurology and Neurosurgery · doi:10.1016/s0303-8467(96)00593-8 · Cited by 78 · cited 1×
“parameters than some previously developed reflex quantification systems which involved sensors or EMG that provided few measures of tendon reflex [3,15,17].”
Electrodiagnosis of polyneuropathy
Johnsen, B., & Fuglsang‐Frederiksen, A. (2000) · Neurophysiologie Clinique · doi:10.1016/s0987-7053(00)00237-9 · Cited by 66
Tendon reflex variability and method of stimulation
Stam, J., & Tan, K. M. (1987) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(87)90010-1 · Cited by 64 · cited 2×
“There was also evidence suggesting that tendon taps produced by the instrumented hammer were unpleasant to the subjects [20].”
Biceps femoris tendon jerk reflexes are enhanced at the end of the swing phase in humans
de Crommert, H. W. A. A. V., Faist, M., Berger, W., & Duysens, J. (1996) · Brain Research · doi:10.1016/0006-8993(96)00885-2 · Cited by 56
System identification of tendon reflex dynamics
Zhang, L.-Q., Huang, H., Sliwa, J. A., & Rymer, W. Z. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.769410 · Cited by 53 · cited 9×
“The proposed method is simple and does not necessitate complicated setups compared to systems that are tethered or fixed to static or bulky structures [12,13,19].”
InfluentialMeasurement of tendon reflexes by surface electromyography in normal subjects
Stam, J., & van Crevel, H. (1989) · Journal of Neurology · doi:10.1007/bf00314505 · Cited by 51 · cited 2×
“Surface electromyography (SEMG) is most commonly applied as the method to quantify reflex responses [3,13–16].”
Kinematic quantitation of the patellar tendon reflex using a tri-axial accelerometer
Mamizuka, N., Sakane, M., Kaneoka, K., Hori, N., & Ochiai, N. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.10.003 · Cited by 47 · cited 5×
“Instrumented hammer involved those of Stam and van Crevel (1989), attaching an ordinary reflex hammer to a piezo-electric transducer, and of Mamizuka et al. (2007), who collected quantitative input data by placing a force sensor at the hammer tip.”
Influential
Cited by
Lemoyne, R. C., Kerr, W. T., Zanjani, K., & Mastroianni, T. (2013) · Journal of Medical Imaging and Health Informatics · doi:10.1166/jmihi.2014.1219 · Cited by 37
“Multiple forces settings for quantified reflex input were derived from a reflex hammer attached to a protractor [26,27].”
MethodInfluence of Age on Patellar Tendon Reflex Response
Chandrasekhar, A., Abu Osman, N. A., Tham, L. K., Lim, K. S., & Wan Abas, W. A. B. (2013) · PLoS ONE · doi:10.1371/journal.pone.0080799 · Cited by 31
“ensured to be at the same level as the tendon before being released from a particular angle measured by the attached set-square [22,23], as shown in Figure 2.”
BackgroundMethodResultInfluentialSelf-citationLemoyne, R. C., & Mastroianni, T. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944415 · Cited by 29
Tsuji, H., Misawa, H., Takigawa, T., Tetsunaga, T., Yamane, K., Oda, Y., & Ozaki, T. (2021) · Scientific Reports · doi:10.1038/s41598-021-81874-5 · Cited by 16
Classification and Assessment of the Patelar Reflex Response through Biomechanical Measures
Salazar-Muñoz, Y., López-Pérez, G. A., García-Caballero, B. E., Muñoz-Rios, R., Ruano-Calderón, L. A., & Trujillo, L. (2019) · Journal of Healthcare Engineering · doi:10.1155/2019/1614963 · Cited by 8
“Some work has attempted to quantify the test by performing motion analysis [15] in cerebral palsy children [16] and also proposed a new iPhone application to measure the reflex response [17].”
Background
Metadata
- Authors
- Tham, L. K., Abu Osman, N. A., Wan Abas, W. A. B., & Lim, K. S.
- Affiliations
- University of Malaya (MY)
- Corresponding author
- Tham, Lai Kuan
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2013-02-07
- Volume
- 8
- Issue
- 2
- Pages
- e55702
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC3567131
- OpenAlex
- W1968567484
- Cited by
- 32
- References
- 26
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 4 · 2023: 1 · 2021: 6 · 2020: 2 · 2019: 1 · 2018: 1 · 2017: 1 · 2016: 2 · 2015: 6 · 2014: 1 · 2013: 4
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- The University of Malaya Research Repository (University of Malaya) (acceptedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Health Sciences › Medicine › Clinical Neurology › Peripheral Nerve Disorders
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- patellar reflex, deep tendon reflexes, motion analysis, knee joint angle, reflex amplitude, neuromuscular disorders, reproducibility
- MeSH terms
- Humans, Motion, Reference Values, Patellar Ligament
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-09-30, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-09-30 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Validity and Reliability of Motion Analysis in Patellar Tendon Reflex Assessment. https://app.cochat.ai/papers/10.1371/journal.pone.0055702
- The paper
- Tham, L. K., Abu Osman, N. A., Wan Abas, W. A. B., & Lim, K. S. (2013). The Validity and Reliability of Motion Analysis in Patellar Tendon Reflex Assessment. PLoS ONE. https://doi.org/10.1371/journal.pone.0055702
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.