A new statistic for steady-state evoked potentials
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Steady-state evoked potentials are often characterized by the amplitude and phase of the Fourier component at one or more frequencies of interest. We introduce a new statistic for the evaluation of these Fourier components. This statistic, denoted T2circ, is based on the same physiologic assumptions concerning the sources of variability of a Fourier component that are made in the use of the Rayleigh phase-coherence statistic as well as the standard T2 statistic (Hotelling 1931) for multivariate data. However, the T2circ statistic also exploits the relationship between the real and imaginary components of Fourier estimates, which is not exploited by T2, and utilizes amplitude information, which is ignored by the Rayleigh criterion. For these reasons, the T2circ statistic is more efficient than previously used criteria for detection and quantitation of steady-state responses, both in principle and in practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biometry: The Principles and Practice of Statistics in Biological Research
Sokal, R. R., & Rohlf, F. J. (1969) · Cited by 20,963
Biometry: The Principles and Practice of Statistics in Biological Research
Campbell, R. C., Sokal, R. R., & Rohlf, F. J. (1970) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2343822 · Cited by 3,955
Introduction to Multivariate Statistical Analysis.
Madow, W. G., & Anderson, T. W. (1959) · The American Mathematical Monthly · doi:10.2307/2308777 · Cited by 3,878
Statistics of Directional Data.
Gokhale, D. V., & Mardia, K. V. (1973) · Biometrics · doi:10.2307/2529189 · Cited by 2,442
Statistics of Directional Data
Watson, G. S. (1973) · Technometrics · doi:10.1080/00401706.1973.10489127 · Cited by 1,499
The Generalization of Student's Ratio
Hotelling, H. (1931) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177732979 · Cited by 1,492
The Generalization of Student’s Ratio
Hotelling, H. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-0919-5_4 · Cited by 1,083
Some characteristics of average steady-state and transient responses evoked by modulated light
Regan, D. (1966) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(66)90088-5 · Cited by 524
Spatial frequency sweep VEP: Visual acuity during the first year of life
Norcia, A. M., & Tyler, C. W. (1985) · Vision Research · doi:10.1016/0042-6989(85)90217-2 · Cited by 422
Regan, D. (1989) · Medical Entomology and Zoology · Cited by 366
Kupersmith, M. J. (1989) · American Journal of Ophthalmology · doi:10.1016/0002-9394(89)90137-2 · Cited by 254
The (±) Reference: Accuracy of Estimated Mean Components in Average Response Studies
Schimmel, H. (1967) · Science · doi:10.1126/science.157.3784.92 · Cited by 214
Human visual responses to sinusoidally modulated light
van der Tweel, L. H., & Verduyn Lunel, H. F. E. (1965) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(65)90076-3 · Cited by 206
Rapid objective refraction using evoked brain potentials.
Regan, D. M. (1973) · PubMed · Cited by 143
Reliability estimates for steady-state evoked potentials
Picton, T. W., Vajsar, J., Rodriguez, R. A., & Campbell, K. B. (1987) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(87)90039-6 · Cited by 129
Auditory steady-state responses: threshold prediction using phase coherence
Stapells, D. R., Makeig, S., & Galambos, R. (1987) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(87)90024-1 · Cited by 123
Receptive field mechanisms of cat X and Y retinal ganglion cells.
Victor, J. D., & Shapley, R. M. (1979) · The Journal of General Physiology · doi:10.1085/jgp.74.2.275 · Cited by 94
Self-citationRetinal ganglion cell response to sinusoidal light stimulation.
Hughes, G. W., & Maffei, L. (1966) · Journal of Neurophysiology · doi:10.1152/jn.1966.29.3.333 · Cited by 88
THE ANALYSIS OF STEADY STATE EVOKED POTENTIALS REVISITED
Strasburger, H. (1987) · GoeScholar The Publication Server of the Georg-August-Universität Göttingen (Georg-August-Universität Göttingen) · Cited by 45
Cited by
The steady-state visual evoked potential in vision research: A review
Norcia, A. M., Appelbaum, L. G., Ales, J. M., Cottereau, B. R., & Rossion, B. (2015) · Journal of Vision · doi:10.1167/15.6.4 · Cited by 1,234
Steady-state visually evoked potentials: Focus on essential paradigms and future perspectives
Vialatte, F.-B., Maurice, M., Dauwels, J., & Cichocki, A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.11.005 · Cited by 1,066
Human auditory steady-state responses: Respuestas auditivas de estado estable en humanos
Picton, T. W., John, M. S., Dimitrijevic, A., & Purcell, D. (2003) · International Journal of Audiology · doi:10.3109/14992020309101316 · Cited by 846
Collinear stimuli regulate visual responses depending on cell's contrast threshold
Polat, U., Mizobe, K., Pettet, M. W., Kasamatsu, T., & Norcia, A. M. (1998) · Nature · doi:10.1038/35372 · Cited by 598
Multiple Channel Detection of Steady-State Visual Evoked Potentials for Brain-Computer Interfaces
Friman, O., Volosyak, I., & Graser, A. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889160 · Cited by 541
Metadata
- Authors
- Victor, J. D., & Mast, J.
- Venue
- Electroencephalography and Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 1991-05
- Volume
- 78
- Issue
- 5
- Pages
- 378-388
- ISSN
- 0013-4694 (ISSN-L)
- OpenAlex
- W1972771533
- Cited by
- 315
- References
- 19
- FWCI
- 2.49
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.