The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Human auditory steady-state responses: Respuestas auditivas de estado estable en humanos
Abstract
Steady-state evoked potentials can be recorded from the human scalp in response to auditory stimuli presented at rates between 1 and 200 Hz or by periodic modulations of the amplitude and/or frequency of a continuous tone. Responses can be objectively detected using frequency-based analyses. In waking subjects, the responses are particularly prominent at rates near 40 Hz. Responses evoked by more rapidly presented stimuli are less affected by changes in arousal and can be evoked by multiple simultaneous stimuli without significant loss of amplitude. Response amplitude increases as the depth of modulation or the intensity increases. The phase delay of the response increases as the intensity or the carrier frequency decreases. Auditory steady-state responses are generated throughout the auditory nervous system, with cortical regions contributing more than brainstem generators to responses at lower modulation frequencies. These responses are useful for objectively evaluating auditory thresholds, assessing suprathreshold hearing, and monitoring the state of arousal during anesthesia.Los potenciales evocados de estado estable pueden registrarse del cráneo humano en respuesta a estímulos auditivos presentados a tasas de 1 y 200 Hz o por modulaciones periódicas de la amplitud y/o de la frecuencia de un tono continue Las respuestas pueden ser detectadas objetivamente por medio de un análisis frecuencial En sujetos en estado de alerta las respuestas son particularmente prominentes con tasas de estimulación cercanas a 40 Hz. Las respuestas evocadas por estímulos presentados a tasa más rápida resultan menos afectadas por cambios del estado de conciencia y pueden ser evocados por estímulos múltiples simultáneos sin una pérdida significativa de la amplitud. La amplitud de la respuesta aumenta conforme la profundidad de la modulación o de la intensidad aumenta. El retraso de fase de la respuesta aumenta conforme la intensidad de la frecuencia portadora aumenta. Las respuestas auditivas de estado estable se generan a todo lo largo del sistema nervioso auditivo; las regiones corticales contribuyen más que los generadores del tallo cerebral en las respuestas de frecuencias más bajas. Estas respuestas son útiles para evaluar objetivamente los umbrales de audición y permiten también evaluar la audición supraliminar y monitorizar el estado de conciencia durante la anestesia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An algorithm for the machine calculation of complex Fourier series
Cooley, J. W., & Tukey, J. W. (1965) · Mathematics of Computation · doi:10.1090/s0025-5718-1965-0178586-1 · Cited by 13,154
Representation of the temporal envelope of sounds in the human brain
Giraud, A.-L., Lorenzi, C., Ashburner, J., Wable, J., Johnsrude, I., Frackowiak, R., & Kleinschmidt, A. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.3.1588 · Cited by 353
Ketamine increases the amplitude of the 40-Hz auditory steady-state response in humans
Plourde, G., Baribeau, J., & Bonhomme, V (1997) · British Journal of Anaesthesia · doi:10.1093/bja/78.5.524 · Cited by 121
Cited by
Hearing Impairment and Cognitive Energy: The Framework for Understanding Effortful Listening (FUEL)
Pichora-Fuller, M. K., Kramer, S. E., Eckert, M. A., Edwards, B., Hornsby, B. W. Y., Humes, L. E., Lemke, U., Lunner, T., Matthen, M., Mackersie, C. L., et al. (2016) · Ear & Hearing · doi:10.1097/aud.0000000000000312 · Cited by 1,318
Thut, G., Schyns, P. G., & Gross, J. (2011) · Frontiers in Psychology · doi:10.3389/fpsyg.2011.00170 · Cited by 560
Visual and Auditory Brain–Computer Interfaces
Gao, S., Wang, Y., Gao, X., & Hong, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2300164 · Cited by 449
Envelope and spectral frequency-following responses to vowel sounds
Aiken, S. J., & Picton, T. W. (2008) · Hearing Research · doi:10.1016/j.heares.2008.08.004 · Cited by 356
Self-citationIndividual Differences Reveal Correlates of Hidden Hearing Deficits
Bharadwaj, H. M., Masud, S., Mehraei, G., Verhulst, S., & Shinn-Cunningham, B. G. (2015) · The Journal of Neuroscience · doi:10.1523/jneurosci.3915-14.2015 · Cited by 314
Metadata
- Authors
- Picton, T. W., John, M. S., Dimitrijevic, A., & Purcell, D.
- Venue
- International Journal of Audiology
- Publisher
- Informa UK Limited
- Published
- 2003-01
- Volume
- 42
- Issue
- 4
- Pages
- 177-219
- ISSN
- 1499-2027 (ISSN-L)
- 1708-8186
- OpenAlex
- W1976359337
- Cited by
- 846
- References
- 3
- FWCI
- 10.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Human auditory steady-state responses: Respuestas auditivas de estado estable en humanos. https://app.cochat.ai/papers/10.3109/14992020309101316
- The paper
- Picton, T. W., John, M. S., Dimitrijevic, A., & Purcell, D. (2003). Human auditory steady-state responses: Respuestas auditivas de estado estable en humanos. International Journal of Audiology. https://doi.org/10.3109/14992020309101316
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.