Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.

Neuromagnetic source imaging with FOCUSS: a recursive weighted minimum norm algorithm

Gorodnitsky, Irina F., George, John S., Rao, Bhaskar D. · 1995 · Electroencephalography and Clinical Neurophysiology

Abstract

The paper describes a new algorithm for tomographic source reconstruction in neural electromagnetic inverse problems. Termed FOCUSS (FOCal Underdetermined System Solution), this algorithm combines the desired features of the two major approaches to electromagnetic inverse procedures. Like multiple current dipole modeling methods, FOCUSS produces high resolution solutions appropriate for the highly localized sources often encountered in electromagnetic imaging. Like linear estimation methods, FOCUSS allows current sources to assume arbitrary shapes and it preserves the generality and ease of application characteristic of this group of methods. It stands apart from standard signal processing techniques because, as an initialization-dependent algorithm, it accommodates the non-unique set of feasible solutions that arise from the neuroelectric source constraints. FOCUSS is based on recursive, weighted norm minimization. The consequence of the repeated weighting procedure is, in effect, to concentrate the solution in the minimal active regions that are essential for accurately reproducing the measurements. The FOCUSS algorithm is introduced and its properties are illustrated in the context of a number of simulations, first using exact measurements in 2- and 3-D problems, and then in the presence of noise and modeling errors. The results suggest that FOCUSS is a powerful algorithm with considerable utility for tomographic current estimation.

Overview

Integrity signals

Registry

Crossref · 10.1016/0013-4694(95)00107-a

Cites

49 of 49 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 49 references

Research works printed but not linked: 3

  1. Gorodnitsky, 1994, Analysis of regularization error in Tikhonov regularization and truncated singular value decomposition methods, Vol. 1
  2. Gorodnitsky, 1992, Weighted linear estimator procedures for neuromagnetic source reconstruction, J. Neuroimaging, 1, 54
  3. Van Veen, 1992, Localization of intracerebral sources of elecrical activity via linearly constrained minimum variance spatial filtering, Vol. 1, 157

Cited by

See all 567

Metadata

Authors
Gorodnitsky, I. F., George, J. S., & Rao, B. D.
Affiliations
  • University of California San Diego (US)
  • Los Alamos National Laboratory (US)
Corresponding author
Gorodnitsky, Irina F.
Venue
Electroencephalography and Clinical Neurophysiology
Publisher
Elsevier BV
Published
1995-10
Volume
95
Issue
4
Pages
231-251
ISSN
0013-4694 (ISSN-L)
OpenAlex
W2065919982
Cited by
567
References
49
Citations by year
2026: 1 · 2025: 15 · 2024: 10 · 2023: 12 · 2022: 14 · 2021: 18 · 2020: 26 · 2019: 12 · 2018: 19 · 2017: 28 · 2016: 20 · 2015: 34 · 2014: 19 · 2013: 22 · 2012: 20
FWCI
3.39
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • Electroencephalography and Clinical Neurophysiology (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health (5r01ey008610-10)
  • National Eye Institute (EY08610)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
  • Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Bioimpedance Tomography
Keywords
FOCUSS, electromagnetic inverse problems, linear estimation, underdetermined systems, source localization
MeSH terms
Algorithms, Brain Mapping, Humans, Image Processing, Computer-Assisted, Models, Neurological, Magnetoencephalography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Neuromagnetic source imaging with FOCUSS: a recursive weighted minimum norm algorithm. https://app.cochat.ai/papers/10.1016/0013-4694(95)00107-a
The paper
Gorodnitsky, I. F., George, J. S., & Rao, B. D. (1995). Neuromagnetic source imaging with FOCUSS: a recursive weighted minimum norm algorithm. Electroencephalography and Clinical Neurophysiology. https://doi.org/10.1016/0013-4694(95)00107-a

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.