Light transmission of the cornea in whole human eyes
Abstract
The transmission of the cornea for light in the wavelength range 450-1000 nm was measured in steps of 50 nm by means of a photodiode implanted into the anterior chamber of whole human donor eyes. In the range from 450 nm up to 600 nm the percentage transmission was found to increase with wavelength from 80% up to 94%. In the range from 60 nm up to 1000 nm the percentage transmission was between 95% and 98%. The corneal transmission for donors younger than 45 yr (n = 3, 22-43 yr) did not differ significantly from that of donors older than 45 yr (n = 5, 67-87 yr) at any wavelength.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Between 600 nm and 1000 nm, transmission values above 95% were recorded in the human cornea.
“but, unlike Boettner and Wolter (1962), between 600 nm and 1000 nm, transmission values above 95% were recorded.”
From Corneal structure and transparency (2015) · cites this paper as Beems and Van Best, 1990
Cited by
Sorted by citations
Corneal structure and transparency
Meek, K. M., & Knupp, C. (2015) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.07.001 · Cited by 853 · see citing works
- Authors
- Beems, E. M., & Van Best, J. A.
- Affiliations
- Leiden University Medical Center (NL)
- Venue
- Experimental Eye Research
- Publisher
- Elsevier BV
- Published
- 1990-04
- Volume
- 50
- Issue
- 4
- Pages
- 393-395
- ISSN
- 0014-4835 (ISSN-L)
- OpenAlex
- W2083294787
- Cited by
- 108
- References
- 0
- Citations by year
- 2026: 8 · 2025: 6 · 2024: 7 · 2023: 5 · 2022: 4 · 2021: 8 · 2020: 3 · 2019: 3 · 2018: 1 · 2017: 1 · 2016: 6 · 2015: 9 · 2014: 7 · 2013: 2 · 2012: 5
- FWCI
- 0.44
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Experimental Eye Research (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal surgery and disorders
- Health Sciences › Medicine › Ophthalmology › Ocular and Laser Science Research
- Health Sciences › Medicine › Epidemiology › Ophthalmology and Visual Impairment Studies
- Keywords
- cornea, human donor eyes, wavelength dependence, UV transmission, age effects, anterior chamber
- MeSH terms
- Adult, Age Factors, Aged, Aged, 80 and over, Cornea, Humans, Light, Middle Aged, Spectrophotometry, Optics and Photonics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review