A portal‐arterial glucose concentration gradient as a signal for an insulin‐dependent net glucose uptake in perfused rat liver
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Since in the usual perfusion of isolated rat liver via the portal vein an insulin‐dependent increase of hepatic glucose uptake could not be demonstrated, the possibility was considered that hepatic glucose uptake might not be a function of the absolute concentration of this substrate but of its concentration gradient between the portal vein and the hepatic artery. Therefore a new method was established for the simultaneous perfusion of isolated rat liver via both the hepatic artery (20–35% flow) and the portal vein (80–6596 flow). When glucose was offered in a concentration gradient, 9.5 mM in the portal vein and 6 mM in the hepatic artery, insulin given via both vessels caused a shift from net glucose release to uptake. This insulin‐dependent shift was not observed when glucose was offered without a gradient or with an inverse gradient, 6 mM in the portal vein and 9.5 mM in the hepatic artery. Using a portal‐arterial glucose gradient as a signal the liver might be able to differentiate between endogenous and exogenous glucose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functional Hepatocellular Heterogeneity
Jungermann, K., & Katz, N. (1982) · Hepatology · doi:10.1002/hep.1840020316 · Cited by 370
Self-citationForearm Glucose Uptake During the Oral Glucose Tolerance Test in Normal Subjects
Jackson, R. A., Peters, N., Advani, U., Perry, G., Rogers, J., Brough, W. H., & Pilkington, T. R. E. (1973) · Diabetes · doi:10.2337/diab.22.6.442 · Cited by 139
Cited by
Metabolic zonation of the liver: Regulation and implications for liver function
Gebhardt, R. (1992) · Pharmacology & Therapeutics · doi:10.1016/0163-7258(92)90055-5 · Cited by 607
Hepatic glucose uptake, gluconeogenesis and the regulation of glycogen synthesis.
Radziuk, J., & Pye, S. (2001) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.217 · Cited by 267
Burcelin, R., Da Costa, A., Drucker, D., & Thorens, B. (2001) · Diabetes · doi:10.2337/diabetes.50.8.1720 · Cited by 250
The role of the autonomic nervous liver innervation in the control of energy metabolism
Yi, C.-X., la Fleur, S. E., Fliers, E., & Kalsbeek, A. (2010) · Biochimica et Biophysica Acta (BBA) - Molecular Basis of Disease · doi:10.1016/j.bbadis.2010.01.006 · Cited by 228
Glucose sensing by the hepatoportal sensor is GLUT2-dependent: in vivo analysis in GLUT2-null mice.
Burcelin, R., Dolci, W., & Thorens, B. (2000) · Diabetes · doi:10.2337/diabetes.49.10.1643 · Cited by 209
Metadata
- Authors
- Gardemann, A., Strulik, H., & Jungermann, K.
- Venue
- FEBS Letters
- Publisher
- Wiley
- Published
- 1986-07-07
- Volume
- 202
- Issue
- 2
- Pages
- 255-259
- ISSN
- 0014-5793 (ISSN-L)
- 1873-3468
- OpenAlex
- W1988232252
- Cited by
- 92
- References
- 2
- FWCI
- 1.93
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.