CoChat

The primary oxygen sensor of the cat carotid body is cytochrome a3 of the mitochondrial respiratory chain

Open access
Wilson, David F., Mokashi, Anil, Chugh, Deepak, Vinogradov, Sergei, Osanai, Shinobu, Lahiri, Sukhamay · 1994 · FEBS Letters
Cited by 122

The DOI matches its Crossref record.

Abstract

Carbon monoxide was shown to be competitive with O 2 in oxygen sensing by perfused carotid bodies isolated from cats, afferent electrical activity increasing with either decreasing O 2 or increasing CO. The CO‐induced increase in afferent activity was fully reversed by bright light. At submaximal light intensities the extent of reversal, after correcting to equal light intensity of light quanta at each wavelength, was maximal for light of 432 ± 2 and 590 ± 2 nm, with a ratio (432/590) of approximately 6. This spectrum is characteristic of the CO compound of mitochondrial cytochrome a 3. The photo‐reversible inhibition of oxygen sensing activity by CO accounts for at least 80% of the oxygen chemosensory activity of the carotid body.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0014-5793(94)00887-6

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 122

Metadata

Authors
Wilson, D. F., Mokashi, A., Chugh, D., Vinogradov, S., Osanai, S., & Lahiri, S.
Venue
FEBS Letters
Publisher
Wiley
Published
1994-09-12
Volume
351
Issue
3
Pages
370-374
ISSN
  • 0014-5793 (ISSN-L)
  • 1873-3468
OpenAlex
W2068628705
Cited by
122
References
0
FWCI
3.08
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The primary oxygen sensor of the cat carotid body is cytochrome a3 of the mitochondrial respiratory chain. https://app.cochat.ai/papers/10.1016/0014-5793(94)00887-6
The paper
Wilson, D. F., Mokashi, A., Chugh, D., Vinogradov, S., Osanai, S., & Lahiri, S. (1994). The primary oxygen sensor of the cat carotid body is cytochrome a3 of the mitochondrial respiratory chain. FEBS Letters. https://doi.org/10.1016/0014-5793(94)00887-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.