The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Laser-induced fluorescence spectroscopy of human colonic mucosa
Open accessAbstract
To evaluate the potential of laser-induced fluorescence spectroscopy for the detection of premalignant lesions of the gastrointestinal tract, the hypothesis that adenomatous transformation of colonic mucosa results in an alteration of laser-induced fluorescence that enables its differentiation from normal or hyperplastic tissue was tested. A fiberoptic catheter coupled to a helium-cadmium laser (325 nm) and an optical multichannel analyzer were used to obtain fluorescence spectra (350-600 nm) from 35 normal colonic specimens and 35 resected adenomatous polyps. A score based on six wavelengths was derived by stepwise multivariate linear regression analysis of the spectra. The mean score (+/- SEM) was + 0.86 +/- 0.06 for normal mucosa and -0.86 +/- 0.06 for adenomatous polyps (P less than 0.001). Spectra from an additional 34 normal specimens, 16 adenomatous polyps, and 16 hyperplastic polyps were prospectively classified with accuracies of 100%, 100%, and 94%, respectively. The mean score for hyperplastic polyps was significantly different from adenomatous (P less than 0.001) but not from normal tissue. Thus, quantitative analysis of fluorescence spectra enables the detection of adenomatous transformation in colonic mucosa.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comparison of Stopping Rules in Forward “Stepwise” Regression
Bendel, R. B., & Afifi, A. A. (1977) · Journal of the American Statistical Association · doi:10.1080/01621459.1977.10479905 · Cited by 885
Cited by
QUANTITATIVE OPTICAL SPECTROSCOPY FOR TISSUE DIAGNOSIS
Richards-Kortum, R., & Sevick-Muraca, E. (1996) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.47.1.555 · Cited by 1,172
In Vivo Fluorescence Spectroscopy and Imaging for Oncological Applications
Wagnieres, G. A., Star, W. M., & Wilson, B. C. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb02521.x · Cited by 942
Fluorescence Spectroscopy of Neoplastic and Non-Neoplastic Tissues
Ramanujam, N. (2000) · Neoplasia · doi:10.1038/sj.neo.7900077 · Cited by 654
Autofluorescence spectroscopy and imaging: a tool for biomedical research and diagnosis
Croce, A. C., & Bottiroli, G. (2014) · European Journal of Histochemistry · doi:10.4081/ejh.2014.2461 · Cited by 628
Pancolonic indigo carmine dye spraying for the detection of dysplasia in ulcerative colitis
Rutter, M. D., Saunders, B. P., Schofield, G., Forbes, A., Price, A. B., & Talbot, I. C. (2004) · Gut · doi:10.1136/gut.2003.016386 · Cited by 520
Metadata
- Authors
- Kapadia, C. R., Cutruzzola, F. W., O'Brien, K. M., Stetz, M. L., Enriquez, R., & Deckelbaum, L. I.
- Venue
- Gastroenterology
- Publisher
- Elsevier BV
- Published
- 1990-07
- Volume
- 99
- Issue
- 1
- Pages
- 150-157
- ISSN
- 0016-5085 (ISSN-L)
- OpenAlex
- W2337748576
- Cited by
- 230
- References
- 1
- FWCI
- 5.57
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Laser-induced fluorescence spectroscopy of human colonic mucosa. https://app.cochat.ai/papers/10.1016/0016-5085(90)91242-x
- The paper
- Kapadia, C. R., Cutruzzola, F. W., O'Brien, K. M., Stetz, M. L., Enriquez, R., & Deckelbaum, L. I. (1990). Laser-induced fluorescence spectroscopy of human colonic mucosa. Gastroenterology. https://doi.org/10.1016/0016-5085(90)91242-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.