Effect of inert regions on local mass transfer rate measurements using the limiting diffusion current technique—case of Poiseuille type flow
The DOI matches its Crossref record.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Moreover, because the surface of the insulation is not isothermal, the heat transfer downstream is altered [6, 7].”
From Analysis and design of experimental systems for heat transfer measurement from constant-temperature surfaces (1989) · cites this paper as [7]
In the citing paper
“The temperature drop on the surface of the insulation strip upstream of a measurement plate changes the development of the thermal boundary layer [6, 7].”
From Analysis and design of experimental systems for heat transfer measurement from constant-temperature surfaces (1989) · cites this paper as [7]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 7
- Lin, 1951, Diffusion-controlled electrode reactions, Ind. Engng Chem., 43, 2136, 10.1021/ie50501a045 · doi:10.1021/ie50501a045
- Reiss, 1962, Measurement of instantaneous rates of mass transfer to a small sink on a wall, A.I.Ch.E. Jl, 8, 245, 10.1002/aic.690080223 · doi:10.1002/aic.690080223
- Grassman, 1979, Application of the electrolytic method—I. Advantages and disadvantages, mass transfer between a falling film and the wall, Int. J. Heat Mass Transfer, 22, 795, 10.1016/0017-9310(79)90018-8 · doi:10.1016/0017-9310(79)90018-8
- Tagg, 1979, Heat and mass transfer downstream of abrupt nozzle expansions in turbulent flow, Trans. Instn Chem. Engrs, 57, 176
- Wragg, 1980, Diffusion controlled current distributions near cell entries and corners, J. Appl. Electrochem., 10, 43, 10.1007/BF00937336 · doi:10.1007/bf00937336
- Aggarwal, 1979, Electro-chemical measurements of mass transfer in semi-cylindrical hollows, Int. J. Heat Mass Transfer, 22, 61, 10.1016/0017-9310(79)90099-1 · doi:10.1016/0017-9310(79)90099-1
- Kim, 1983, Experimental study of mass transfer around a turbulence promoter by the limiting current method, Int. J. Heat Mass Transfer, 26, 1007, 10.1016/S0017-9310(83)80125-2 · DOI
Cited by
VandenBerghe, T., & Diller, T. E. (1989) · Experimental Thermal and Fluid Science · doi:10.1016/0894-1777(89)90039-3 · Cited by 7
Metadata
- Authors
- Chang, H. N., Park, J. K., & Cheol, K.
- Venue
- International Journal of Heat and Mass Transfer
- Publisher
- Elsevier BV
- Published
- 1984-10
- Volume
- 27
- Issue
- 10
- Pages
- 1922-1925
- ISSN
- 0017-9310
- Cited by
- 3
- References
- 0
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of inert regions on local mass transfer rate measurements using the limiting diffusion current technique—case of Poiseuille type flow. https://app.cochat.ai/papers/10.1016/0017-9310(84)90174-1
- The paper
- Chang, H. N., Park, J. K., & Cheol, K. (1984). Effect of inert regions on local mass transfer rate measurements using the limiting diffusion current technique—case of Poiseuille type flow. International Journal of Heat and Mass Transfer. https://doi.org/10.1016/0017-9310(84)90174-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.