A design method is presented to minimize experimental uncertainties and errors resulting from heat losses in a common type of constant-wall-temperature convection measurement system. The system consists of one or more thick, individually heated metallic plates that are exposed to convection on the top face, with electric heaters on the bottom surface, and are surrounded on all four sides by thermal insulation and/or guard heaters. A heat balance, which includes thermal losses, is applied to the measurement plate to determine the average heat transfer coefficient over the plate. A generalized analysis was made of the convection and conduction heat transfer in the insulation strips separating heated plates. On the basis of this analysis, the correction for the heat lost from a measurement plate and an estimate of the uncertainty of the measurement are presented. The results are presented in the form of generalized (dimensionless) plots of insulation temperature drop, heat losses, and corrections for losses. The effect of an insulation temperature drop on the isothermal wall temperature boundary condition was also considered. It is shown how the results can be used to minimize the over-all correction for losses and the experimental uncertainty by optimizing the design of the insulation strips between plates. As an example, the analytical and optimization methods are applied to a typical experimental system.

Overview

CoChat Summary

TL;DR

The paper develops a generalized analytical/numerical method to quantify and minimize heat-loss corrections and uncertainty in constant-temperature heated-plate heat transfer measurements, including conduction and convection through insulation strips. It provides dimensionless design plots and an example showing an optimal insulation width of about 0.16 cm for a representative system.

Key findings

  • An exact series solution is presented for conduction and convection from heated plates through adjacent insulation strips; for \(w/d \le 1\), the convection loss depends only on \(Bi_w\) and insulation depth does not affect it, and conduction between plates can usually be treated as one-dimensional with good accuracy.
  • In a sample design based on Ref. 12 (\(Bi_L = 7.1\), \(T_a/(T_w - T_\infty) = -0.02\)), a good design point is \(w \approx 0.16\) cm (1/16 in); fractional convection loss is about 3% using \(\varepsilon'\) (with \(h\) determined over \(L + w\)), conduction uncertainty is less than 5%, centerline temperature drop \(\theta_c\) is less than 30%, and the approximate laminar-flow effect over the plate for \(w/L = 0.15\) and \(1 < x_0/L < 5\) is a 6–9% heat transfer increase.
  • The one-dimensional conduction approximation is usually sufficient: at \(w = 0.16\) cm (\(w/d = 0.125\)), \(\varepsilon_2 \approx 4\%\) and the one-dimensional \(q_{L2}\) is 3% higher than the two-dimensional value; at \(w/d = 1\), the one-dimensional \(q_{L2}\) is 30% higher but \(\varepsilon_2 < 1\%\), so the difference is negligible. A realistic maximum value of \(T_a/(T_w - T_\infty)(1/Bi_L) = 0.004\) gives a maximum one-dimensional error of 0.34% for all \(w/d\).
  • Uncertainty from convection losses is \(e_{qL1} < 10\%\) (terms usually about 5%), while \(e_{qL2}\) typically ranges from 1 to 1.5, so the uncertainty in \(h\) associated with \(Q_{L2}\) is at least as large as the predicted \(q_{L2}\); the best design criterion for convection losses is to keep \(\varepsilon\) small. An insulation temperature drop can affect heat flux; for \(\theta_c = 10\%\) and \(w/L < 0.1\), the maximum error is about 3%.

Methods

  • A two-dimensional heat conduction model was used for the insulation strip; the dimensionless temperature distribution was solved as an infinite series with a constant heat transfer coefficient boundary condition at the free surface, and heat losses were found by integrating the temperature gradient at the plate-insulation boundary. The series were evaluated numerically, and the nonisothermal boundary effect was estimated by superposition using a laminar flat-plate boundary layer with a parabolic surface temperature profile and an unheated starting length, with 100 and 1000 steps used to check convergence.
  • Uncertainty was estimated using standard external error analysis. The sample design used parameters based on experiments in Ref. 12, with \(Bi_L = 7.1\) and \(T_a/(T_w - T_\infty) = -0.02\), varying insulation width \(w\) while holding \(L\), \(d\), \(T_w - T_\infty\), \(T_a\), \(h\), and \(k\) constant; iteration was required because \(\varepsilon_1\) (or \(\varepsilon'\)) and \(\varepsilon_2\) depend on each other. Assumed uncertainties were \(\omega_{Ta} = \pm T_a\), and \(\omega_w = \pm 0.39\) mm for \(w \ge 0.78\) mm and \(\omega_w = \pm w/2\) for \(w < 0.78\) mm.

Limitations

  • Stated: back-surface and radiation losses are not included in the analysis because they are generally easy to calculate. The analysis assumes the temperature difference between plates \(T_a\) can be controlled as accurately as it can be measured, typically between 0.1°C and 1.0°C; in the sample, actual experimental uncertainties would exceed 5% if \(T_a\) were not controlled within the assumed \(\pm 0.2\)°C.
  • Stated: the nonisothermal insulation effect is estimated with a laminar flat-plate boundary layer and a parabolic temperature profile; actual boundary-layer development depends on pressure gradient, freestream turbulence, and surface curvature, and Fig. 8 is intended to illustrate the effect rather than provide a correction. Turbulent boundary layers would show a smaller effect than laminar ones for the same conditions.
  • Stated/evident: there is a design tradeoff limiting accuracy and spatial resolution—reducing both \(\varepsilon_2\) and \(\varepsilon\) requires increasing \(Bi_L\), usually by increasing heated-plate size, which increases measurement area and decreases resolution; accurate measurement over small areas is therefore limited. The one-dimensional conduction approximation may deviate for large \(w/d\), though the correction is usually small.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1016/0894-1777(89)90039-3

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

0 Valid · 6 Not valid · 7 Not checked · 62 Own results and interpretations

35 more claims

Create a free account to see all 75 claims and to verify the 9 references still open.

See all claims — free account
  • It may state two separate claims as one. 24
  • Probably not a substantial claim. 12

Create a free account to see these claims.

Citations

Cites

Show all 17 references

Research works printed but not linked: 1

  1. 10. Ozisik, M. N., Heat Conduction, Wiley, New York, pp. 25–65, 1984.

Cited by

See all 7

Metadata

Authors
VandenBerghe, T., & Diller, T. E.
Affiliations
  • Cummins (United States) (US)
  • Virginia Tech (US)
Corresponding author
Diller, T.E.
Venue
Experimental Thermal and Fluid Science
Publisher
Elsevier BV
Published
1989-04
Volume
2
Issue
2
Pages
236-246
ISSN
0894-1777 (ISSN-L)
OpenAlex
W2089561934
Cited by
7
References
19
Citations by year
2015: 1 · 2013: 1
FWCI
1.26
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
Experimental Thermal and Fluid Science (publishedVersion)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
  • Physical Sciences › Engineering › Computational Mechanics › Heat Transfer and Numerical Methods
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer Mechanisms
Keywords
heat transfer measurement, heat loss correction, heat balance, measurement uncertainty, heat transfer coefficient, isothermal boundary conditions

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-18, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-18 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Analysis and design of experimental systems for heat transfer measurement from constant-temperature surfaces. https://app.cochat.ai/papers/10.1016/0894-1777(89)90039-3
The paper
VandenBerghe, T., & Diller, T. E. (1989). Analysis and design of experimental systems for heat transfer measurement from constant-temperature surfaces. Experimental Thermal and Fluid Science. https://doi.org/10.1016/0894-1777(89)90039-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.