The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Variations in strength and structure of cancellous bone at the knee
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Cortical porosity is negatively correlated with Young’s modulus (42), compressive ultimate stress (43), and fracture toughness (44).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [43]
Citations
Cites
The mechanics of the knee joint in relation to normal walking
Morrison, J. B. (1970) · Journal of Biomechanics · doi:10.1016/0021-9290(70)90050-3 · Cited by 1,062
Koch, J. C. (1917) · American Journal of Anatomy · doi:10.1002/aja.1000210202 · Cited by 628
The mechanical properties of bone.
Evans, F. G. (1969) · PubMed · Cited by 562
Mechanical influences in bone remodeling. Experimental research on Wolff's law
Chamay, A., & Tschantz, P. (1972) · Journal of Biomechanics · doi:10.1016/0021-9290(72)90053-x · Cited by 463
Precision and Accuracy of Bone Mineral Determination by Direct Photon Absorptiometry
CAMERON, J. R., Mazess, R. B., & Sorenson, J. A. (1968) · Investigative Radiology · doi:10.1097/00004424-196805000-00001 · Cited by 370
Physical properties of trabecular bone
Galante, J. O., Rostoker, W., & Ray, R. D. (1970) · Calcified Tissue International · doi:10.1007/bf02017552 · Cited by 302
On the mathematical analysis of stress in the human femur
Rybicki, E. F., Simonen, F. A., & Weis, E. B. (1972) · Journal of Biomechanics · doi:10.1016/0021-9290(72)90056-5 · Cited by 286
Tibial Osteotomy in Gonarthrosis (Osteo-Arthritis of the Knee)
BAUER, G. C. H., Insall, J. N., & Koshino, T. (1969) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-196951080-00005 · Cited by 267
The ultimate properties of bone tissue: The effects of yielding
Burstein, A. H., Currey, J. D., Frankel, V. H., & Reilly, D. T. (1972) · Journal of Biomechanics · doi:10.1016/0021-9290(72)90017-6 · Cited by 254
Weaver, J. K., & Chalmers, J. P. (1966) · PubMed · Cited by 248
Research works printed but not linked: 3
- Burstein, 1970, Elastic analysis of condylar structures, ASME 2–11
- Pugh, 1972, Studies of the subchondial cancellous bone in patients with osteoarthritis, Technical Report No. 3 to the Office of Naval Research Ref. 471: WGR: pwh, NR 023–534
- Wolff, 1870, Uber die innere Architektur der knochen und ihre Bedeutung fur die Frame vom knockenwachstum Virchows Arch, Bd 50
Cited by
Sorted by citations
Items 101–168 of 168
Mechanical behaviour of trabecular bone of the human femoral head in females
Deligianni, D. D., Missirlis, Y. F., Tanner, K. E., & Bonfield, W. (1991) · Journal of Materials Science Materials in Medicine · doi:10.1007/bf00692976 · Cited by 16
Coronal Knee Alignment 40 Years after Total Meniscectomy in Adolescents: A Prospective Cohort Study
Pengas, I. P., Nash, W. J., Khan, W. S., Assiotis, A., Banks, J., & McNicholas, M. J. (2017) · The Open Orthopaedics Journal · doi:10.2174/1874325001711010424 · Cited by 15
Cancellous bone material properties in osteoarthritic and rheumatoid total knee patients
Wixson, R. L., Elasky, N., & Lewis, J. L. (1989) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100070615 · Cited by 15
Petersen, M. M. (2001) · Acta Orthopaedica Scandinavica · doi:10.1080/000164702760300293 · Cited by 15
Goldstein, S. A., Frankenburg, E. P., & Kuhn, J. L. (1993) · Springer eBooks · doi:10.1007/978-1-4757-2264-2_9 · Cited by 15
The loss of stiffness as osteoporosis progresses
Werner, H. J., Martin, H., Behrend, D., Schmitz, K., & Schober, H. (1996) · Medical Engineering & Physics · doi:10.1016/1350-4533(96)00012-4 · Cited by 15
Distribution of bone mineral density in the proximal tibia in mid-teens
Tsuji, T., Kitano, K., Yamano, Y., Sato, T., & Koike, T. (2001) · Journal of Bone and Mineral Metabolism · doi:10.1007/s007740170019 · Cited by 14
The Fixation of Femoral Components of Condylar Knee Prostheses
Walker, P. S., Granholm, J. W., & Lowrey, R. (1982) · Engineering in Medicine · doi:10.1243/emed_jour_1982_011_038_02 · Cited by 14
Self-citationLereim, P., & Goldie, I. F. (1975) · Archiv für Orthopädische und Unfall-Chirurgie · doi:10.1007/bf00417022 · Cited by 13
Dual-photon absorptiometry of the proximal tibia
Hvid, I., Hasling, C., Hansen, S. L., & Hansen, H. H. (1987) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/bf00454340 · Cited by 13
Dong, X., Yeni, Y. N., Zhang, B., Les, C. M., Gibson, G. J., & Fyhrie, D. P. (2005) · Calcified Tissue International · doi:10.1007/s00223-004-0140-y · Cited by 12
Bone morphology in relation to the migration of porous-coated anatomic knee arthroplasties
Tägil, M., Hansson, U., Sigfusson, R., Carlsson, Å., Johnell, O., Lidgren, L., Toksvig‐Larsen, S., & Ryd, L. (2003) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(03)00111-6 · Cited by 10
Mechanical properties of rat epiphyseal cancellous bones studied by indentation testing
An, Y. H., ZHANG, J., Kang, Q. K., & Friedman, R. J. (1997) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1018530327291 · Cited by 10
Vijayakumar, V., & Quenneville, C. E. (2016) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411916642800 · Cited by 9
The Total-Condylar Knee and Its Evolution
Walker, P. S. (1985) · Springer eBooks · doi:10.1007/978-1-4612-5050-0_3 · Cited by 9
Self-citationEffects of loading rate, age, and morphology on the material properties of human rib trabecular bone
Albert, D. L., Katzenberger, M. J., Hunter, R. L., Agnew, A. M., & Kemper, A. R. (2023) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111670 · Cited by 8
Pelland, L., & McKinley, P. A. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2004.02.003 · Cited by 8
Principles of total knee arthroplasty.
Dennis, D. A. (1991) · PubMed · Cited by 8
Benum, P., Lyng, S., Alm, T., & Johannessen, N. B. (1977) · Acta Orthopaedica Scandinavica · doi:10.3109/17453677708985126 · Cited by 8
An experimental simulation model to assess wear of the porcine patellofemoral joint
Cowie, R. M., Bowland, P., Baji, D., Fermor, H. L., Ingham, E., Fisher, J., & Jennings, L. M. (2021) · PLoS ONE · doi:10.1371/journal.pone.0250077 · Cited by 7
Trabecular bone densitometry using interactive image analysis
Austriaco, N. P. G., Williams, J. L., & Drummond, D. S. (1991) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(91)90095-o · Cited by 7
Development and Application of Ultrasound Backscatter Methods for the Diagnostics of Trabecular Bone
Riekkinen, O. (2008) · Cited by 7
Shore, S. W., Unnikrishnan, G. U., Hussein, A. I., & Morgan, E. F. (2012) · CRC Press eBooks · doi:10.1201/b13733-3 · Cited by 6
Mechanische Eigenschaften nativer und präparierter Spongiosa
Thulĺ, R., Sturm, A., & Pesch, H.-J. (1993) · Springer eBooks · doi:10.1007/978-3-642-78188-9_34 · Cited by 6
Compressive strength of canine femur
KENNER, G. H., Taylor, L. C., & Park, J. B. (1979) · Journal of Biomechanics · doi:10.1016/0021-9290(79)90040-x · Cited by 6
The Genesis cemented modular total knee prosthesis: a 3-year follow-up study
Laskin, R. S. (1994) · The Knee · doi:10.1016/0968-0160(94)90008-6 · Cited by 6
Rooryck, V., & Klinge, B. (1995) · Acta Odontologica Scandinavica · doi:10.3109/00016359509005957 · Cited by 6
An investigation on osteoporosis based on guided wave propagation in multi-layered bone plates
Lee, M.-Y., Jeyaprakash, N., & Yang, C. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.105026 · Cited by 5
Qu Feng Zhi Tong capsule increases mechanical properties of cortical bone in ovariectomised rats
Li, L., Xiao-min, Y., Huang, C., Shi, K., Wang, J., Zeng, Q., Cheng, W., He, X., Zhang, P., Qiu, G., et al. (2020) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2020.02.001 · Cited by 5
Remodelling of Trabecular Bone at the Proximal Tibia after Total Knee Replacement. A CT-Scan Study
Hvid, I., Bentzen, S. M., & Jørgensen, J. B. (1986) · Engineering in Medicine · doi:10.1243/emed_jour_1986_015_025_02 · Cited by 5
Correlations between the mechanical properties, radiology and histomorphometry of human femoral bone
Matthews, S., Pearcy, M. J., Fazzalari, N. L., Parkinson, I. H., Manthey, B. A., Schultz, C. G., & Howie, D. W. (1992) · Clinical Biomechanics · doi:10.1016/0268-0033(92)90030-8 · Cited by 5
Kiss, M.-O., Levasseur, A., Petit, Y., & Lavigne, P. (2012) · The American Journal of Sports Medicine · doi:10.1177/0363546512438382 · Cited by 4
Numerical measurement of contact pressure in the tibiofemoral joint during gait
Nor, N. M. M., Osman, N. A. A., & Oshkour, A. (2012) · doi:10.1109/icobe.2012.6178951 · Cited by 4
Bone strength measurements at the proximal tibia
Hvid, I., Jensen, J., & Nielsen, S. (1986) · International Orthopaedics · doi:10.1007/bf00454408 · Cited by 4
A validated finite element study of stress shielding in a novel hybrid knee implant
Mahboob, Z. (2021) · doi:10.32920/ryerson.14649990 · Cited by 4
Multiscale modeling of viscoelastic behavior in demineralized human trabecular bone
Xiong, Z., Bensidhoum, M., Ferry, D., Huang, X., Potier, E., & Hoc, T. (2025) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2025.110887 · Cited by 3
Research of elasticity for a corrugated wire mesh
Choi, J., Shankar, K., & Lee, J. (2013) · Materials & Design (1980-2015) · doi:10.1016/j.matdes.2013.05.019 · Cited by 3
Intracortical remodelling increases in highly loaded bone after exercise cessation
Silva, R., Sun, T. C., Mishra, A. P., BOYDE, A., Doube, M., & Riggs, C. M. (2023) · Journal of Anatomy · doi:10.1111/joa.13969 · Cited by 3
Advanced Mechanics of Hard Tissue Using Imaging-Based Measurements and Artificial Intelligence
Tozzi, G., & Buehler, M. J. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-90646-3.00046-0 · Cited by 5
Bone Density, Distribution, and Estimated Strength
Cann, C. E., Brown, J. K., & Iwashita, A. (1995) · Springer eBooks · doi:10.1007/978-4-431-66939-5_12 · Cited by 3
Failure mechanisms in total knee arthroplasty
Bonnin, M. P. (2008) · Springer eBooks · doi:10.1007/978-2-287-74175-3_13 · Cited by 2
Buttermann, G. R., & Mendenhall, H. V. (2012) · Journal of Investigative Surgery · doi:10.3109/08941939.2011.605204 · Cited by 2
Causes d’échec mécanique des prothèses totales du genou
Bonnin, M. P. (2007) · Springer eBooks · doi:10.1007/2-287-30285-9_21 · Cited by 2
Bünger, C. E., & Hvid, I. (1987) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678709146517 · Cited by 2
Tibial plateau strength patterns in experimental modular knee replacement
Hvid, I., & M�ller, J. T. (1985) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/bf00449959 · Cited by 2
Au, A. G., Otto, D. D., Raso, V. J., & Amirfazli, A. (2003) · Elsevier eBooks · doi:10.1016/b978-008044046-0.50394-8 · Cited by 2
Proximal tibial stress lines—appearances on magnetic resonance imaging of the knee
Hacking, J. C., Mackenzie, R., & Dixon, A. K. (1995) · British Journal of Radiology · doi:10.1259/0007-1285-68-812-933 · Cited by 1
The Tibial Sulcus as a Reference Point for Total Knee Arthroplasty
Kelmanovich, D. J., Russinoff, S., Maldjian, C., Lucas, P. A., & Zelicof, S. B. (2008) · Orthopedics · doi:10.3928/01477447-20080501-13 · Cited by 1
Nonunion of tibial stress fractures in patients with deformed arthritic knees
Bernard, J. (2000) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.82b3.0820464a · Cited by 1
Finite Element Stress Analysis of the Human Knee
Hayes, W. C., & Swenson, L. W. (1981) · Elsevier eBooks · doi:10.1016/b978-0-12-281602-4.50006-3 · Cited by 1
A biomechanical study of a novel biomimetic hip implant
Khurshid, S. (2021) · doi:10.32920/ryerson.14647719.v1 · Cited by 1
Management of Problem Knees in Total Knee Replacement
Bae, D. K., Lee, S., & Ahn, J. (1988) · Springer eBooks · doi:10.1007/978-4-431-68075-8_9
Journal of Bone and Mineral Research
Cann, C. E. (1993) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650081321
Lee, S. C., Nam, C. H., Yoon, J. Y., Jung, K. A., Hwang, B. H., & Ahn, H. S. (2012) · The Journal of the Korean Orthopaedic Association · doi:10.4055/jkoa.2012.47.5.368
Klinische Wertigkeit von Druckbelastungstests an spongiösen Knochenquadern
Ehall, R., EUSTACCHIO, E., & PEICHA, G. (2009) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1992.37.s1.254
Paprosky, W. G., Sekundiak, T. D., & Kronick, J. L. (2002) · Springer eBooks · doi:10.1007/0-387-21714-2_59
Baek, M., Won, Y., Cui, W.-Q., & Kim, Y. (2009) · AJOU Open Repository (Ajou University)
Penetration tests and epiphyseal compressive strength
Hvid, I., Jensen, J., & Nielsen, S. (1986)
Tromblee, T. C. (2006) · VTechWorks (Virginia Tech)
Percutaneous repair of the ruptured tendo Achillis
Deakin, S. F., Wood, J. F. H., & Barrie, J. L. (2000) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.82b3.0820461
Walker, P. S. (2020) · Springer eBooks · doi:10.1007/978-3-030-38171-4_8
Self-citationWalker, P. S. (2020) · Springer eBooks · doi:10.1007/978-3-030-38171-4_5
Self-citationSchemitsch, E. H., & Thornhill, T. S. (2002) · Springer eBooks · doi:10.1007/0-387-21714-2_52
Scott, J. W., Ng, K. C. G., Liddle, A. D., & Jeffers, J. R. T. (2024) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2024.106240
Prothetische Versorgung des Kniegelenks
Stoffel, K., & Kuster, M. S. (2002) · Springer eBooks · doi:10.1007/978-3-642-56361-4_16
Bonnin, M. P. (2012) · Springer eBooks · doi:10.1007/978-2-287-99353-4_91
Topographic Variation of Indentation Stiffness in the Tibial Subchondral Plate of the Knee Joint
Kobayashi, S., & Takei, T. (1992) · Springer eBooks · doi:10.1007/978-4-431-68216-5_15
Metadata
- Authors
- Behrens, J. C., Walker, P. S., & Shoji, H.
- Affiliations
- Hospital for Special Surgery (US)
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1974-05
- Volume
- 7
- Issue
- 3
- Pages
- 201-207
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2077321800
- Cited by
- 171
- References
- 13
- Citations by year
- 2025: 1 · 2024: 4 · 2023: 2 · 2021: 6 · 2020: 3 · 2019: 1 · 2018: 5 · 2017: 2 · 2016: 1 · 2015: 1 · 2014: 1 · 2013: 2 · 2012: 8
- FWCI
- 7.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- trabecular bone, knee joint, compressive strength, linear absorption coefficient, osteoarthritis, load-bearing bone
- MeSH terms
- Absorption, Adult, Aged, Arthritis, Rheumatoid, Biomechanical Phenomena, Bone and Bones, Elasticity, Female, Humans, Knee, Male, Middle Aged, Minerals, Osteoarthritis, Pressure, Surface Properties
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review