The mechanical properties of the rabbit and human cornea
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The extensibility of rabbit and human corneas was measured by raising the pressure within the intact globe of the eye and measuring the displacements of two very small mercury drops on the corneal surface. The human cornea showed a negligible extensibility under low stresses. The rabbit tissue, however, underwent a 9% strain under low pressures with a curvilinear relationship between stress and strain. At higher pressures the relationship was linear, and the tissue showed some creep. The low pressure stress-strain relationship of the rabbit could not be explained on the basis that the collagen fibrils were being straightened out from an initial set in a sinusoidal wave. When the stroma was isolated from Descemet's membrane, it showed a negligible low pressure extensibility in rabbit and man. On the other hand, isolated Descemet's membrane was very extensible in both species. The difference between them in the behavior of the intact cornea seems to lie in the relative initial strain in the stroma and Descemet's membrane.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
BIOMECHANICS, Its Foundations and Objectives
Engin, A. E. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90091-2 · Cited by 559
MAURICE, D. M. (1962) · Vegetative Physiology and Biochemistry · doi:10.1016/b978-1-4832-3090-0.50013-7 · Cited by 436
Self-citationNonlinear material properties of intact cornea and sclera
Woo, S. L., KOBAYASHI, A. S., Schlegel, W. A., & Lawrence, C. (1972) · Experimental Eye Research · doi:10.1016/0014-4835(72)90139-x · Cited by 345
Dependence of stress-strain nonlinearity of connective tissues on the geometry of collagen fibres
Comninou, M., & Yannas, I. V. (1976) · Journal of Biomechanics · doi:10.1016/0021-9290(76)90084-1 · Cited by 146
Prenatal and postnatal growth of the human Descemet's membrane.
Murphy, C. G., Alvarado, J. A., & Juster, R. P. (1984) · PubMed · Cited by 131
Striations of light scattering in the corneal stroma
Gallagher, B. C., & Maurice, D. M. (1977) · Journal of Ultrastructure Research · doi:10.1016/s0022-5320(77)90009-0 · Cited by 53
Self-citationStructural implications of small-angle light scattering from cornea
McCally, R. L., & Farrell, R. A. (1982) · Experimental Eye Research · doi:10.1016/0014-4835(82)90012-4 · Cited by 50
Cited by
Liu, J., & Roberts, C. J. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.09.031 · Cited by 753
Indentation Versus Tensile Measurements of Young's Modulus for Soft Biological Tissues
McKee, C. T., Last, J. A., Russell, P., & Murphy, C. J. (2011) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2010.0520 · Cited by 708
Biomechanics and wound healing in the cornea
Dupps, W. J., & Wilson, S. E. (2006) · Experimental Eye Research · doi:10.1016/j.exer.2006.03.015 · Cited by 510
Overcoming the translational barriers of tissue adhesives
Taboada, G. M., Yang, K., Pereira, M. J. N., Liu, S. S., Hu, Y., Karp, J. M., Artzi, N., & Lee, Y. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0171-7 · Cited by 449
The specific architecture of the anterior stroma accounts for maintenance of corneal curvature
Muller, L. J. (2001) · British Journal of Ophthalmology · doi:10.1136/bjo.85.4.437 · Cited by 424
“The difference in swelling behaviour between anterior and posterior stroma is further evidenced by the fact that isolated stromal tissue from rabbit and humans shows negligible extensibility under stress, whereas isolated Descemet's membrane in both species is very extensible under similar conditions.”
Background
Metadata
- Authors
- Jue, B., & Maurice, D. M.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1986
- Volume
- 19
- Issue
- 10
- Pages
- 847-853
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2112149864
- Cited by
- 222
- References
- 7
- FWCI
- 1.26
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.