Strains and micromotions of press-fit femoral stem prostheses
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
“Modes of Failure” of Cemented Stem-Type Femoral Components: A Radiographic Analysis of Loosening
Banaszkiewicz, P. A. (2014) · Classic Papers in Orthopaedics · doi:10.1007/978-1-4471-5451-8_8 · Cited by 3,399
"Modes of Failure" of Cemented Stem-type Femoral Components
Gruen, T. A., McNeice, G. M., & Amstutz, H. C. (1979) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197906000-00002 · Cited by 2,714
Ten-year follow-up study of total hip replacement.
Stauffer, R. N. (1982) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198264070-00003 · Cited by 639
A survey of finite element analysis in orthopedic biomechanics: The first decade
Huiskes, R., & Chao, E. Y. S. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90072-6 · Cited by 539
A biomechanical investigation of the human hip
Crowninshield, R. D., Johnston, R. C., Andrews, J. G., & Brand, R. A. (1978) · Journal of Biomechanics · doi:10.1016/0021-9290(78)90045-3 · Cited by 448
Oh, I., & Harris, W. H. (1978) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-197860010-00010 · Cited by 336
Approaches to design - Force actions transmitted by joints in the human body
Paul, J. P. (1976) · Proceedings of the Royal Society B Biological Sciences · doi:10.1098/rspb.1976.0004 · Cited by 257
Cited by
Biomedical applications of polymer-composite materials: a review
Ramakrishna, S., Mayer, J., Wintermantel, E., & Leong, K. W. (2001) · Composites Science and Technology · doi:10.1016/s0266-3538(00)00241-4 · Cited by 1,642
Hip joint loading during walking and running, measured in two patients
Bergmann, G., Graichen, F., & Rohlmann, A. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90058-m · Cited by 1,276
Keaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90054-x · Cited by 330
The mechanism of bone remodeling and resorption around press-fitted THA stems
Van Rietbergen, B., Huiskes, R., Weinans, H., Sumner, D. R., Turner, T. M., & Galante, J. O. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90001-u · Cited by 299
Is staircase walking a risk for the fixation of hip implants?
Bergmann, G., Graichen, F., & Rohlmann, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00105-d · Cited by 164
Alanazi, B., Munje, C. R., Rastogi, N., Williamson, A. J. K., Taylor, S., Hole, P. S., Hodges, M., Doyle, M., Baker, S., Gilkes, A. F., et al. (2020) · Leukemia · doi:10.1038/s41375-019-0596-4 · Cited by 64
Metadata
- Authors
- Walker, P. S., Schneeweis, D., Murphy, S., & Nelson, P.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1987-01
- Volume
- 20
- Issue
- 7
- Pages
- 693-702
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W1974051406
- Cited by
- 169
- References
- 7
- FWCI
- 5.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.