Hip joint center location from palpable bony landmarks—A cadaver study
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sex differences in the skeletal geometry of the human pelvis and hip joint
Brinckmann, P., Hoefert, H., & Jongen, H. T. (1981) · Journal of Biomechanics · doi:10.1016/0021-9290(81)90060-9 · Cited by 59
Cited by
Wu, G., Siegler, S., Allard, P., Kirtley, C., Leardini, A., Rosenbaum, D., Whittle, M., D’Lima, D. D., Cristofolini, L., Witte, H., et al. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00222-6 · Cited by 3,242
Adjustments to McConville et al. and Young et al. body segment inertial parameters
Dumas, R., Chèze, L., & Verriest, J.-P. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.02.013 · Cited by 554
Human movement analysis using stereophotogrammetry
Della Croce, U., Leardini, A., Chiari, L., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.003 · Cited by 544
A new anatomically based protocol for gait analysis in children
Leardini, A., Sawacha, Z., Paolini, G., Ingrosso, S., Nativo, R., & Benedetti, M. G. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.12.018 · Cited by 491
A survey of formal methods for determining the centre of rotation of ball joints
Ehrig, R. M., Taylor, W. R., Duda, G. N., & Heller, M. O. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.10.002 · Cited by 432
Metadata
- Authors
- Seidel, G. K., Marchinda, D. M., Dijkers, M., & Soutas-Little, R. W.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1995-08
- Volume
- 28
- Issue
- 8
- Pages
- 995-998
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W1969961631
- Cited by
- 200
- References
- 1
- FWCI
- 3.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.